FLIR VT8 Clamp Meter, 200 A 200 A 1000 V dc 1000 V ac CAT III, CAT IV Non-Contact Voltage Detector UKAS
- RS Stock No.:
- 181-2435
- Mfr. Part No.:
- VT8-600
- Brand:
- FLIR
- RS Stock No.:
- 181-2435
- Mfr. Part No.:
- VT8-600
- Brand:
- FLIR
Select all | Attribute | Value |
|---|---|---|
| Brand | FLIR | |
| Product Type | Clamp Meter | |
| Maximum DC Current Measurement | 200A | |
| Maximum AC Voltage Measurement | 1000V ac | |
| Maximum DC Voltage Measurement | 1000V dc | |
| Maximum Resistance Measurement | 60MΩ | |
| Model Number | VT8 | |
| DC Current Resolution | 100mA | |
| Resistance Measurement Accuracy | ±1.5 % | |
| AC Current Resolution | 100mA | |
| DC Current Accuracy | ±2.5 % | |
| AC Current Accuracy | ±2.5 % | |
| Clamp Meter Type | AC-DC Open Jaw Clamp Meter | |
| Maximum Jaw Opening | 15.5mm | |
| DC Voltage Accuracy | ±1 % | |
| Minimum Operating Temperature | 10°C | |
| DC Voltage Resolution | 100 mV dc | |
| AC Voltage Resolution | 100mV ac | |
| AC Voltage Accuracy | ±1 % | |
| Maximum Operating Temperature | 50°C | |
| Standards/Approvals | No | |
| Width | 35mm | |
| Height | 53mm | |
| Length | 210mm | |
| Weight | 163.7g | |
| True RMS | Yes | |
| Functions Measured | AC Current, AC Voltage, Auto Ranging, Capacitance, Continuity, Data Hold, DC Current, DC Voltage, NCV (Non-contact Voltage), Relative Mode, Resistance, True RMS | |
| Display Type | LCD | |
| Safety Category Voltage | 600V | |
| Power Source | Battery | |
| Battery Type | AA | |
| Safety Category Level | CAT III, CAT IV | |
| Non-Contact Voltage Detector | Yes | |
| Calibrated | UKAS | |
| Maximum Temperature Measurement | 60°C | |
| Maximum AC Current Measurement | 200A | |
| Select all | ||
|---|---|---|
Brand FLIR | ||
Product Type Clamp Meter | ||
Maximum DC Current Measurement 200A | ||
Maximum AC Voltage Measurement 1000V ac | ||
Maximum DC Voltage Measurement 1000V dc | ||
Maximum Resistance Measurement 60MΩ | ||
Model Number VT8 | ||
DC Current Resolution 100mA | ||
Resistance Measurement Accuracy ±1.5 % | ||
AC Current Resolution 100mA | ||
DC Current Accuracy ±2.5 % | ||
AC Current Accuracy ±2.5 % | ||
Clamp Meter Type AC-DC Open Jaw Clamp Meter | ||
Maximum Jaw Opening 15.5mm | ||
DC Voltage Accuracy ±1 % | ||
Minimum Operating Temperature 10°C | ||
DC Voltage Resolution 100 mV dc | ||
AC Voltage Resolution 100mV ac | ||
AC Voltage Accuracy ±1 % | ||
Maximum Operating Temperature 50°C | ||
Standards/Approvals No | ||
Width 35mm | ||
Height 53mm | ||
Length 210mm | ||
Weight 163.7g | ||
True RMS Yes | ||
Functions Measured AC Current, AC Voltage, Auto Ranging, Capacitance, Continuity, Data Hold, DC Current, DC Voltage, NCV (Non-contact Voltage), Relative Mode, Resistance, True RMS | ||
Display Type LCD | ||
Safety Category Voltage 600V | ||
Power Source Battery | ||
Battery Type AA | ||
Safety Category Level CAT III, CAT IV | ||
Non-Contact Voltage Detector Yes | ||
Calibrated UKAS | ||
Maximum Temperature Measurement 60°C | ||
Maximum AC Current Measurement 200A | ||
- COO (Country of Origin):
- CN
FLIR Clamp metre, AC-DC, True RMS - VT8-600
Features & Benefits
Applications
Can it measure both AC and DC voltage and current accurately?
Will it help me detect live AC voltages without contact?
Is it suitable for professionals working in the automation industry?
Related links
- FLIR VT8 Clamp Meter CAT IV Non-Contact Voltage Detector UKAS
- FLIR VT8 Clamp Meter CAT IV Non-Contact Voltage Detector
- FLIR VT8 Clamp Meter CAT IV Non-Contact Voltage Detector RSCAL
- FLIR CM275 Clamp Meter CAT IV Non-Contact Voltage Detector UKAS
- Fluke 374 FC Clamp Meter CAT IV Non-Contact Voltage Detector UKAS
- Fluke 375 FC Clamp Meter CAT IV Non-Contact Voltage Detector UKAS
- Fluke 376 Clamp Meter CAT IV Non-Contact Voltage Detector UKAS
- Fluke 376 FC Clamp Meter CAT IV Non-Contact Voltage Detector UKAS