FLIR VT8 Clamp Meter, 100 A dc 100 A ac 600 V dc 1000 V ac CAT III, CAT IV Non-Contact Voltage Detector, UKAS
- RS Stock No.:
- 181-2435
- Mfr. Part No.:
- VT8-600
- Brand:
- FLIR
- RS Stock No.:
- 181-2435
- Mfr. Part No.:
- VT8-600
- Brand:
- FLIR
Select all | Attribute | Value |
|---|---|---|
| Brand | FLIR | |
| Product Type | Clamp Meter | |
| Maximum DC Current Measurement | 100A dc | |
| Maximum AC Voltage Measurement | 1000V ac | |
| Maximum DC Voltage Measurement | 600V dc | |
| Maximum Resistance Measurement | 60MΩ | |
| Model Number | VT8 | |
| DC Voltage Accuracy | ±1 % | |
| Clamp Meter Type | AC-DC Open Jaw Clamp Meter | |
| Resistance Measurement Accuracy | ±1.5 % | |
| AC Current Resolution | 100mA | |
| AC Voltage Resolution | 100mV ac | |
| AC Voltage Accuracy | ±1.5 % | |
| Minimum Operating Temperature | -10°C | |
| Maximum Jaw Opening | 15.5mm | |
| DC Voltage Resolution | 100 mV dc | |
| AC Current Accuracy | ±2.5 % | |
| DC Current Accuracy | ±2.5 % | |
| DC Current Resolution | 100mA | |
| Maximum Operating Temperature | 50°C | |
| Weight | 163.7g | |
| Width | 35mm | |
| Height | 53mm | |
| Length | 210mm | |
| Standards/Approvals | No | |
| True RMS | Yes | |
| Functions Measured | AC Current, AC Voltage, Auto Ranging, Capacitance, Continuity, Data Hold, DC Current, DC Voltage, NCV (Non-contact Voltage), Relative Mode, Resistance, True RMS | |
| Power Source | Battery | |
| Display Type | LCD | |
| Battery Type | AA | |
| Calibrated | UKAS | |
| Non-Contact Voltage Detector | Yes | |
| Safety Category Level | CAT III, CAT IV | |
| Maximum Temperature Measurement | 60°C | |
| Safety Category Voltage | 300V, 600V | |
| Maximum AC Current Measurement | 100A ac | |
| Select all | ||
|---|---|---|
Brand FLIR | ||
Product Type Clamp Meter | ||
Maximum DC Current Measurement 100A dc | ||
Maximum AC Voltage Measurement 1000V ac | ||
Maximum DC Voltage Measurement 600V dc | ||
Maximum Resistance Measurement 60MΩ | ||
Model Number VT8 | ||
DC Voltage Accuracy ±1 % | ||
Clamp Meter Type AC-DC Open Jaw Clamp Meter | ||
Resistance Measurement Accuracy ±1.5 % | ||
AC Current Resolution 100mA | ||
AC Voltage Resolution 100mV ac | ||
AC Voltage Accuracy ±1.5 % | ||
Minimum Operating Temperature -10°C | ||
Maximum Jaw Opening 15.5mm | ||
DC Voltage Resolution 100 mV dc | ||
AC Current Accuracy ±2.5 % | ||
DC Current Accuracy ±2.5 % | ||
DC Current Resolution 100mA | ||
Maximum Operating Temperature 50°C | ||
Weight 163.7g | ||
Width 35mm | ||
Height 53mm | ||
Length 210mm | ||
Standards/Approvals No | ||
True RMS Yes | ||
Functions Measured AC Current, AC Voltage, Auto Ranging, Capacitance, Continuity, Data Hold, DC Current, DC Voltage, NCV (Non-contact Voltage), Relative Mode, Resistance, True RMS | ||
Power Source Battery | ||
Display Type LCD | ||
Battery Type AA | ||
Calibrated UKAS | ||
Non-Contact Voltage Detector Yes | ||
Safety Category Level CAT III, CAT IV | ||
Maximum Temperature Measurement 60°C | ||
Safety Category Voltage 300V, 600V | ||
Maximum AC Current Measurement 100A ac | ||
- COO (Country of Origin):
- CN
FLIR Clamp metre, AC-DC, True RMS - VT8-600
Features & Benefits
Applications
Can it measure both AC and DC voltage and current accurately?
Will it help me detect live AC voltages without contact?
Is it suitable for professionals working in the automation industry?
Related links
- FLIR VT8 Clamp Meter CAT IV Non-Contact Voltage Detector
- FLIR VT8 Clamp Meter CAT IV Non-Contact Voltage Detector, UKAS
- FLIR VT8 Clamp Meter CAT IV Non-Contact Voltage Detector, RSCAL
- FLIR VT8 Clamp Meter CAT IV Non-Contact Voltage Detector, RSCAL
- FLIR CM275 Clamp Meter CAT IV Non-Contact Voltage Detector, UKAS
- Fluke 375 FC Clamp Meter CAT IV Non-Contact Voltage Detector, UKAS
- Fluke 374 FC Clamp Meter CAT IV Non-Contact Voltage Detector, UKAS