Select all | Attribute | Value |
|---|---|---|
| Brand | Fluke | |
| Product Type | Clamp Meter | |
| Maximum DC Current Measurement | 600A dc | |
| Resistance Resolution | 10Ω | |
| Maximum AC Voltage Measurement | 1000V ac | |
| Maximum DC Voltage Measurement | 1000V dc | |
| Maximum Resistance Measurement | 60kΩ | |
| Model Number | 375 FC | |
| AC Current Accuracy | ±2 % rdg + 5 Digits | |
| DC Voltage Accuracy | ±1 % rdg + 5 Digits | |
| DC Voltage Resolution | 100 mV dc | |
| Clamp Meter Type | AC/DC Clamp Meter | |
| DC Current Resolution | 100mA | |
| DC Current Accuracy | ±2 % rdg + 5 Digits | |
| Resistance Measurement Accuracy | ±1 % rdg + 5 Digits | |
| Minimum Operating Temperature | -10°C | |
| AC Voltage Accuracy | ±1.5 % rdg + 5 Digits | |
| AC Current Resolution | 100mA | |
| Maximum Jaw Opening | 34mm | |
| AC Voltage Resolution | 100mV ac | |
| Maximum Operating Temperature | 50°C | |
| Width | 85mm | |
| Standards/Approvals | IEC 61010-1IEC 61010-2-032IEC 61010-2-033IEC 60529: IP30FCC ID:T68-FBLEIC:6627A-FBLEIEC 61326-1IEC 61326-2-2CISPR 11 | |
| Weight | 395g | |
| Length | 246mm | |
| Height | 45mm | |
| Functions Measured | DC Current, Temperature, AC Current, AC Voltage, Resistance, DC Voltage | |
| True RMS | Yes | |
| Safety Category Level | CAT III, CAT IV | |
| Safety Category Voltage | 1000V | |
| Power Source | Battery | |
| Calibrated | UKAS | |
| Non-Contact Voltage Detector | Yes | |
| Display Type | LCD Backlight | |
| Battery Type | AA IEC LR06 | |
| Maximum AC Current Measurement | 600A ac | |
| Select all | ||
|---|---|---|
Brand Fluke | ||
Product Type Clamp Meter | ||
Maximum DC Current Measurement 600A dc | ||
Resistance Resolution 10Ω | ||
Maximum AC Voltage Measurement 1000V ac | ||
Maximum DC Voltage Measurement 1000V dc | ||
Maximum Resistance Measurement 60kΩ | ||
Model Number 375 FC | ||
AC Current Accuracy ±2 % rdg + 5 Digits | ||
DC Voltage Accuracy ±1 % rdg + 5 Digits | ||
DC Voltage Resolution 100 mV dc | ||
Clamp Meter Type AC/DC Clamp Meter | ||
DC Current Resolution 100mA | ||
DC Current Accuracy ±2 % rdg + 5 Digits | ||
Resistance Measurement Accuracy ±1 % rdg + 5 Digits | ||
Minimum Operating Temperature -10°C | ||
AC Voltage Accuracy ±1.5 % rdg + 5 Digits | ||
AC Current Resolution 100mA | ||
Maximum Jaw Opening 34mm | ||
AC Voltage Resolution 100mV ac | ||
Maximum Operating Temperature 50°C | ||
Width 85mm | ||
Standards/Approvals IEC 61010-1IEC 61010-2-032IEC 61010-2-033IEC 60529: IP30FCC ID:T68-FBLEIC:6627A-FBLEIEC 61326-1IEC 61326-2-2CISPR 11 | ||
Weight 395g | ||
Length 246mm | ||
Height 45mm | ||
Functions Measured DC Current, Temperature, AC Current, AC Voltage, Resistance, DC Voltage | ||
True RMS Yes | ||
Safety Category Level CAT III, CAT IV | ||
Safety Category Voltage 1000V | ||
Power Source Battery | ||
Calibrated UKAS | ||
Non-Contact Voltage Detector Yes | ||
Display Type LCD Backlight | ||
Battery Type AA IEC LR06 | ||
Maximum AC Current Measurement 600A ac | ||
RoHS Status: Exempt
- COO (Country of Origin):
- CN
Fluke Clamp Meter, 600A Maximum AC Current, 1000V Maximum DC Voltage - FLUKE-375 FC
Features & Benefits
• 2500 A measurement capability when used with flexible probe for large conductors
• True RMS acquisition for accurate readings on non-linear loads
• Bluetooth connectivity to transmit readings wirelessly to devices
• VFD low-pass filter to obtain correct motor-drive measurements
• Resistance to 60 kΩ and temperature input for multi-parameter troubleshooting
Applications
• Ideal for preventative maintenance and trending of intermittent faults
• Used for site voltage verification and non-contact live detection
• Can be used with logging software for asset condition records
• Suitable for large-current measurement on busbars with flexible probe
What power source and operating temperatures does it support?
How does the instrument handle high-energy work environments?
What measurement accuracy and resolution are provided for current and voltage?
How are intermittent events recorded and reviewed?
What ingress protection and weight considerations affect field use?
Related links
- Fluke 375 FC Clamp Meter CAT IV Non-Contact Voltage Detector
- Fluke 375 FC Clamp Meter CAT IV Non-Contact Voltage Detector RSCAL
- Fluke 374 FC Clamp Meter CAT IV Non-Contact Voltage Detector UKAS
- Fluke 376 FC Clamp Meter CAT IV Non-Contact Voltage Detector UKAS
- Fluke 374 FC Clamp Meter CAT IV Non-Contact Voltage Detector
- Fluke 374 FC Clamp Meter CAT IV Non-Contact Voltage Detector RSCAL
- Fluke 376 FC Clamp Meter CAT IV Non-Contact Voltage Detector
- Fluke 376 FC Clamp Meter CAT IV Non-Contact Voltage Detector RSCAL