Fluke 376 FC Clamp Meter, 999.9 A 2500 A ac 1000 V dc 1000 V ac CAT III, CAT IV Non-Contact Voltage Detector

Subtotal (1 unit)*

£569.90

(exc. VAT)

£683.88

(inc. VAT)

Add to Basket
Select or type quantity
In Stock
  • Plus 36 unit(s) shipping from 20 April 2026
  • Plus 82 unit(s) shipping from 20 April 2026
  • Plus 30 unit(s) shipping from 22 April 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units
Per unit
1 +£569.90

*price indicative

Calibration Options:

RS Stock No.:
905-5914
Distrelec Article No.:
300-37-363
Mfr. Part No.:
FLUKE-376 FC
Brand:
Fluke
Find similar products by selecting one or more attributes.
Select all

Brand

Fluke

Product Type

Clamp Meter

Resistance Resolution

0.1Ω

Maximum DC Current Measurement

999.9A

Maximum AC Voltage Measurement

1000V ac

Maximum DC Voltage Measurement

1000V dc

Maximum Resistance Measurement

60kΩ

Model Number

376 FC

DC Voltage Resolution

1 V dc

Maximum Jaw Opening

34mm

AC Current Resolution

0.1A

Resistance Measurement Accuracy

±1 % rdg + 5 Digits

Minimum Operating Temperature

-10°C

AC Voltage Accuracy

±1.5 % rdg + 5 Digits

AC Voltage Resolution

0.1V ac

DC Voltage Accuracy

±1 % rdg + 5 Digits

DC Current Resolution

0.1A

DC Current Accuracy

±2 % rdg + 5 Digits

AC Current Accuracy

±3 % rdg + 5 Digits

Clamp Meter Type

AC, DC

Maximum Operating Temperature

50°C

Weight

395g

Length

249mm

Height

45mm

Standards/Approvals

No

Width

85mm

Functions Measured

AC Current, DC Current, Frequency, Capacitance, Resistance, DC Voltage, AC Voltage

True RMS

Yes

Non-Contact Voltage Detector

Yes

Maximum AC Current Measurement

2500A ac

Safety Category Level

CAT III, CAT IV

Safety Category Voltage

1000V

Battery Type

AA IEC LR06

Display Type

LCD Backlight

Power Source

Battery

RoHS Status: Exempt

Fluke Clamp Meter, 999.9A Maximum AC Current, 1000V Maximum AC Voltage - FLUKE 376 FC


This clamp meter is a handheld diagnostic instrument designed for electricians and engineers to measure electrical parameters safely in industrial and commercial environments. It captures AC and DC currents and voltages, Plus frequency, capacitance and resistance, while offering wireless data transfer for remote monitoring and logging. The tool is suited to troubleshooting motor drives, inrush currents and intermittent faults while enabling measurements to be read from a safe distance.

Features & Benefits


• True-RMS measurement for accurate non-linear signal readings
• 999.9A DC and 1000V AC/DC capability for high-power circuits
• iFlex flexible probe extends AC range to 2500A for large conductors
• 0.1A DC resolution for fine current diagnostics and trending
• Integrated non-contact voltage detector for quick live checks
• Backlit LCD improves visibility in low-light maintenance tasks

Applications


• Suitable for motor drive fault analysis and VFD testing
• Ideal for recording inrush current during motor starts
• Used for preventive maintenance and asset trending via wireless logging
• Can be used on large conductors in switchrooms with iFlex probe
• Suitable for field measurements outside the arc flash zone

What power source does it use and how does that affect field use?


It runs on two AA alkaline batteries, providing easy replacement in the field and compatibility with common battery stock.

How does it handle measurements on variable-frequency drives?


It includes a low-pass filter to improve accuracy when measuring VFD-driven motor currents.

What safety categories and standards apply for on-site measurements?


It meets CAT III 1000V and CAT IV 600V ratings and conforms to IEC 61010 safety standards for portable test equipment.

Can it capture intermittent events without constant supervision?


The meter supports logging and min/max/inrush Recording so it can Record variations while technicians perform other tasks.

What resistance and capacitance ranges are available for component checks?


Resistance measurement reaches up to 60kΩ and capacitance measurement extends to 1000μF for verifying circuit components.

Supplied with

• Fluke 376 FC True-RMS Clamp Meter
• 18-inch iFlex® Flexible Current Probe
• TPAK magnetic hanging strap
• TL75 Test Leads
• Two AA batteries (Installed)
• Soft carrying case

Related links