Fluke 374 FC Clamp Meter, 600 A 600 A ac 1000 V dc 1000 V ac CAT III, CAT IV Non-Contact Voltage Detector
- RS Stock No.:
- 905-5911
- Distrelec Article No.:
- 300-37-361
- Mfr. Part No.:
- FLUKE-374 FC
- Brand:
- Fluke
Subtotal (1 unit)*
£547.00
(exc. VAT)
£656.40
(inc. VAT)
FREE delivery for orders over £60.00
- Plus 26 unit(s) shipping from 20 July 2026
- Plus 61 unit(s) shipping from 20 July 2026
- Plus 4 unit(s) shipping from 29 July 2026
Units | Per unit |
|---|---|
| 1 + | £547.00 |
*price indicative
- RS Stock No.:
- 905-5911
- Distrelec Article No.:
- 300-37-361
- Mfr. Part No.:
- FLUKE-374 FC
- Brand:
- Fluke
Select all | Attribute | Value |
|---|---|---|
| Brand | Fluke | |
| Product Type | Clamp Meter | |
| Resistance Resolution | 1Ω | |
| Maximum DC Current Measurement | 600A | |
| Maximum AC Voltage Measurement | 1000V ac | |
| Maximum DC Voltage Measurement | 1000V dc | |
| Maximum Resistance Measurement | 6000Ω | |
| Model Number | 374 FC | |
| DC Voltage Resolution | 100 mV dc | |
| Resistance Measurement Accuracy | ±1 % rdg + 5 Digits | |
| Clamp Meter Type | AC/DC Clamp Meter | |
| DC Voltage Accuracy | ±1 % rdg + 5 Digits | |
| AC Current Accuracy | ±2 % rdg + 5 Digits | |
| Maximum Jaw Opening | 34mm | |
| AC Voltage Resolution | 100mV ac | |
| DC Current Accuracy | ±2 % rdg + 5 Digits | |
| DC Current Resolution | 100mA | |
| AC Voltage Accuracy | ±1.5 % rdg + 5 Digits | |
| Minimum Operating Temperature | -10°C | |
| AC Current Resolution | 100mA | |
| Maximum Operating Temperature | 50°C | |
| Height | 45mm | |
| Standards/Approvals | IEC 61010-1IEC 61010-2-032IEC 61010-2-033IEC 60529: IP30FCC ID:T68-FBLEIC:6627A-FBLEIEC 61326-1IEC 61326-2-2CISPR 11 | |
| Width | 85mm | |
| Weight | 395g | |
| Length | 249mm | |
| Functions Measured | Temperature, Resistance, DC Current, AC Voltage, AC Current, DC Voltage | |
| True RMS | Yes | |
| Maximum AC Current Measurement | 600A ac | |
| Safety Category Level | CAT III, CAT IV | |
| Non-Contact Voltage Detector | Yes | |
| Battery Type | AA IEC LR06 | |
| Display Type | LCD Backlight | |
| Power Source | Battery | |
| Safety Category Voltage | 1000, 600V | |
| Select all | ||
|---|---|---|
Brand Fluke | ||
Product Type Clamp Meter | ||
Resistance Resolution 1Ω | ||
Maximum DC Current Measurement 600A | ||
Maximum AC Voltage Measurement 1000V ac | ||
Maximum DC Voltage Measurement 1000V dc | ||
Maximum Resistance Measurement 6000Ω | ||
Model Number 374 FC | ||
DC Voltage Resolution 100 mV dc | ||
Resistance Measurement Accuracy ±1 % rdg + 5 Digits | ||
Clamp Meter Type AC/DC Clamp Meter | ||
DC Voltage Accuracy ±1 % rdg + 5 Digits | ||
AC Current Accuracy ±2 % rdg + 5 Digits | ||
Maximum Jaw Opening 34mm | ||
AC Voltage Resolution 100mV ac | ||
DC Current Accuracy ±2 % rdg + 5 Digits | ||
DC Current Resolution 100mA | ||
AC Voltage Accuracy ±1.5 % rdg + 5 Digits | ||
Minimum Operating Temperature -10°C | ||
AC Current Resolution 100mA | ||
Maximum Operating Temperature 50°C | ||
Height 45mm | ||
Standards/Approvals IEC 61010-1IEC 61010-2-032IEC 61010-2-033IEC 60529: IP30FCC ID:T68-FBLEIC:6627A-FBLEIEC 61326-1IEC 61326-2-2CISPR 11 | ||
Width 85mm | ||
Weight 395g | ||
Length 249mm | ||
Functions Measured Temperature, Resistance, DC Current, AC Voltage, AC Current, DC Voltage | ||
True RMS Yes | ||
Maximum AC Current Measurement 600A ac | ||
Safety Category Level CAT III, CAT IV | ||
Non-Contact Voltage Detector Yes | ||
Battery Type AA IEC LR06 | ||
Display Type LCD Backlight | ||
Power Source Battery | ||
Safety Category Voltage 1000, 600V | ||
RoHS Status: Exempt
- COO (Country of Origin):
- MY
Fluke Clamp Meter, 600A Maximum AC Current Measurement, 1000V Maximum DC Voltage Measurement - FLUKE-374 FC
Features & Benefits
• 600A jaw range with 2500A flexible-probe compatibility for large conductors
• 1000V measurement capacity with CATIII1000V and CATIV600V safety ratings
• High-accuracy DC current ±2%rdg+5 digits for precise diagnostics
• Resistance and capacitance ranges to 6000Ω and 1000μF for component checks
• Bluetooth wireless output to log and transmit readings remotely
**Applications**
• Ideal for load balancing and power-quality checks in distribution panels
• Used for preventive maintenance where remote logging reduces exposure
• Can be used for installation verification on 1000V-rated electrical systems
• Used with flexible probes to measure large busbars and multi-core cables
Which batteries power the instrument and how are they replaced?
How does the flexible probe extend measurement capability?
What environmental limits affect operation at elevated humidity?
How does the instrument handle measurements on variable-frequency drives?
What ingress protection and standards apply to storage and transport?
Related links
- Fluke 374 FC Clamp Meter CAT IV Non-Contact Voltage Detector, UKAS
- Fluke 374 FC Clamp Meter CAT IV Non-Contact Voltage Detector, RSCAL
- Fluke 376 FC Clamp Meter CAT IV Non-Contact Voltage Detector
- Fluke 375 FC Clamp Meter CAT IV Non-Contact Voltage Detector
- Fluke 375 FC Clamp Meter CAT IV Non-Contact Voltage Detector, RSCAL
- Fluke 375 FC Clamp Meter CAT IV Non-Contact Voltage Detector, UKAS
- Fluke 376 FC Clamp Meter CAT IV Non-Contact Voltage Detector RSCAL
- Fluke 376 FC Clamp Meter CAT IV Non-Contact Voltage Detector UKAS