Eaton xEffect MCB, 1P, 32A Curve C, 240 → 415V AC, 48V DC, 10 kA Breaking Capacity
- RS Stock No.:
- 922-6920
- Mfr. Part No.:
- 102094 FAZ-C32/1-NA
- Brand:
- Eaton
Subtotal (1 unit)*
£36.87
(exc. VAT)
£44.24
(inc. VAT)
FREE delivery for orders over £50.00
In Stock
- Plus 4 unit(s) shipping from 27 October 2025
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | £36.87 |
*price indicative
- RS Stock No.:
- 922-6920
- Mfr. Part No.:
- 102094 FAZ-C32/1-NA
- Brand:
- Eaton
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Eaton | |
| Number of Poles | 1 | |
| Current Rating | 32A | |
| Tripping Characteristics | Type C | |
| Rated AC Voltage | 240 → 415V | |
| Rated DC Voltage | 48V | |
| Breaking Capacity at Maximum Voltage Rating | 10 kA | |
| Range | xEffect | |
| Circuit Breaker Type | MCB | |
| Width | 66mm | |
| Length | 17.8mm | |
| Mounting Style | DIN Rail Mount | |
| Depth | 80mm | |
| Model Number | 102094 | |
| Break Time | Instantaneous | |
| Terminal Contact Type | Screw | |
| Tripping Mechanism | Thermal-Magnetic | |
| Reset Actuator Type | Toggle Switch | |
Select all | ||
|---|---|---|
Brand Eaton | ||
Number of Poles 1 | ||
Current Rating 32A | ||
Tripping Characteristics Type C | ||
Rated AC Voltage 240 → 415V | ||
Rated DC Voltage 48V | ||
Breaking Capacity at Maximum Voltage Rating 10 kA | ||
Range xEffect | ||
Circuit Breaker Type MCB | ||
Width 66mm | ||
Length 17.8mm | ||
Mounting Style DIN Rail Mount | ||
Depth 80mm | ||
Model Number 102094 | ||
Break Time Instantaneous | ||
Terminal Contact Type Screw | ||
Tripping Mechanism Thermal-Magnetic | ||
Reset Actuator Type Toggle Switch | ||
Eaton Miniature Circuit Breakers (MCBs) - FAZ Series
The FAZ series of miniature circuit breakers (MCBs) from Eatons xEffect range has a current limiting design providing fast short-circuit interruption that reduces the let-through electrical energy and overload currents that can damage the circuit.
Ideally suited to control circuits and electrical distribution boards the FAZ series of MCBs offer a wide range of diverse protection characteristics, protecting your electrical equipment against overload damage. For additional safety, the MCB breaker cannot be defeated by holding the handle in the ON position, these MCBs are also finger proof and have a trip-free mechanism.
These MCBs have both a thermal and electromagnetic release, with rated currents of 0.16 A up to 63 A and a switching capacity of 15kA or 10kA depending on the device type.
The FAZ series includes miniature circuit breakers, interlocks, busbars and snap-on accessories including auxiliaries and tripping modules.
Ideally suited to control circuits and electrical distribution boards the FAZ series of MCBs offer a wide range of diverse protection characteristics, protecting your electrical equipment against overload damage. For additional safety, the MCB breaker cannot be defeated by holding the handle in the ON position, these MCBs are also finger proof and have a trip-free mechanism.
These MCBs have both a thermal and electromagnetic release, with rated currents of 0.16 A up to 63 A and a switching capacity of 15kA or 10kA depending on the device type.
The FAZ series includes miniature circuit breakers, interlocks, busbars and snap-on accessories including auxiliaries and tripping modules.
Features and Benefits
Thermal-magnetic overcurrent protection
Power to the miniature circuit breakers can be fed from the line or load side
Clear indication of contact position via front switch toggle
Easy installation on DIN rail. MCB module width of only 17.5 mm (per pole)
Six levels of short-circuit protection, categorized by Type B, C, D, K, S and Z curves
Small modular width of the device and accessories saves space in the panel or equipment, which can lead to cost savings
Available in single pole up to 4 pole
Dual rating for IEC 60947-2 standard
MCB Module widths: 1P 17.5mm, 2P 35mm and 3P 52.5mm
Power to the miniature circuit breakers can be fed from the line or load side
Clear indication of contact position via front switch toggle
Easy installation on DIN rail. MCB module width of only 17.5 mm (per pole)
Six levels of short-circuit protection, categorized by Type B, C, D, K, S and Z curves
Small modular width of the device and accessories saves space in the panel or equipment, which can lead to cost savings
Available in single pole up to 4 pole
Dual rating for IEC 60947-2 standard
MCB Module widths: 1P 17.5mm, 2P 35mm and 3P 52.5mm
Standards
IEC 898; BS/EN60-898; EN50 022/DIN46277-3 (BS5584).
FAZ-C*/* & FAZ-S*/* = IEC/EN60947-2
IEC 60947-2 Relates to Low Voltage Circuit Breakers for use in industrial and similar installations. In the UK these are traditionally known as miniature circuit breakers (MCBs), moulded case circuit breakers
(MCCBs) and also air circuit breakers (ACBs).
FAZ-C*/* & FAZ-S*/* = IEC/EN60947-2
IEC 60947-2 Relates to Low Voltage Circuit Breakers for use in industrial and similar installations. In the UK these are traditionally known as miniature circuit breakers (MCBs), moulded case circuit breakers
(MCCBs) and also air circuit breakers (ACBs).
Standards
IEC 898; BS/EN60-898; EN50 022/DIN46277-3 (BS5584).
FAZ-C*/* & FAZ-S*/* = IEC/EN60947-2
FAZ-C*/* & FAZ-S*/* = IEC/EN60947-2
Eaton Single-Pole MCB, 32A Current Rating, 240V Voltage Rating - FAZ Series - 102094FAZ-C32/1-NA
Features & Benefits
• Thermoplastic housing for durability and resistance to impact
• IP40 rated indicating protection against tools and objects larger than 1mm in size
• B, C and D Type tripping characteristics for versatility
• Mechanical service life of 20,000 operating cycles for long-term performance
• IP40 rated indicating protection against tools and objects larger than 1mm in size
• B, C and D Type tripping characteristics for versatility
• Mechanical service life of 20,000 operating cycles for long-term performance
What tools do I need to terminate conductor cables to this MCB?
To terminate conductors to this MCB, you only need a screwdriver to tighten the screw terminals.
How safe is this MCB?
In addition to thermoplastic housing which doubles as an insulator, this unit's terminals are located out of reach of your fingers to prevent contact with live parts.
Note
Eaton formerly known as Moeller
Related links
- Eaton xEffect FAZ MCB 32A Curve C 10 kA Breaking Capacity
- Eaton xEffect MCB 32A Curve C 10 kA Breaking Capacity
- Eaton xEffect MCB 30A Curve C 48V DC, 10 kA Breaking Capacity
- Eaton xEffect MCB 6A Curve C 48V DC, 10 kA Breaking Capacity
- Eaton xEffect MCB 20A Curve C 48V DC, 10 kA Breaking Capacity
- Eaton xEffect MCB 16A Curve C 48V DC, 10 kA Breaking Capacity
- Eaton xEffect MCB 3A Curve C 48V DC, 10 kA Breaking Capacity
- Eaton xEffect MCB 4A Curve C 48V DC, 10 kA Breaking Capacity