Endress+Hauser DMA25 Series Electromagnetic Flowmeter Flow Meter for Liquid, 0.2L/min Min, 150L/min Max
- RS Stock No.:
- 256-6155
- Distrelec Article No.:
- 303-51-194
- Mfr. Part No.:
- DMA25-AAABA1
- Brand:
- Endress+Hauser
Image representative of range
Subtotal (1 unit)*
£567.45
(exc. VAT)
£680.94
(inc. VAT)
FREE delivery for orders over £60.00
In Stock
- 7 unit(s) ready to ship
- Plus 20 unit(s) ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | £567.45 |
*price indicative
- RS Stock No.:
- 256-6155
- Distrelec Article No.:
- 303-51-194
- Mfr. Part No.:
- DMA25-AAABA1
- Brand:
- Endress+Hauser
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Endress+Hauser | |
| Media Monitored | Liquid | |
| Product Type | Flow Meter | |
| Device Type | Electromagnetic Flowmeter | |
| Minimum Flow Rate | 0.2L/min | |
| Maximum Flow Rate | 150L/min | |
| Housing Material | 316L Stainless Steel | |
| Connection Type | Thread | |
| Maximum Pressure | 16bar | |
| IP Rating | IP65, IP67 | |
| Maximum Supply Voltage | 30V dc | |
| Minimum Media Temperature | -10°C | |
| Maximum Media Temperature | 70°C | |
| Minimum Operating Temperature | -10°C | |
| Maximum Operating Temperature | 60°C | |
| Series | DMA25 | |
| Standards/Approvals | CE mark | |
| Select all | ||
|---|---|---|
Brand Endress+Hauser | ||
Media Monitored Liquid | ||
Product Type Flow Meter | ||
Device Type Electromagnetic Flowmeter | ||
Minimum Flow Rate 0.2L/min | ||
Maximum Flow Rate 150L/min | ||
Housing Material 316L Stainless Steel | ||
Connection Type Thread | ||
Maximum Pressure 16bar | ||
IP Rating IP65, IP67 | ||
Maximum Supply Voltage 30V dc | ||
Minimum Media Temperature -10°C | ||
Maximum Media Temperature 70°C | ||
Minimum Operating Temperature -10°C | ||
Maximum Operating Temperature 60°C | ||
Series DMA25 | ||
Standards/Approvals CE mark | ||
- COO (Country of Origin):
- FR
Endress+Hauser DMA25 Series Flow Meter, 0.2 L/min Minimum Flow Rate, 150 L/min Maximum Flow Rate - DMA25-AAABA1
This flow metre measures volumetric liquid flow using electromagnetic sensing and is suited to inline monitoring within industrial systems. It is designed for threaded-connection installations and performs across typical process temperature ranges while operating from a low-voltage DC supply. The unit is enclosed in a robust 316L stainless-steel housing and accommodates moderate process pressures for general plant integration.
Features and Benefits:
• 0.2-150 L/min span delivering wide operational coverage for varied rates
• 30V DC maximum supply enabling low-voltage control-system integration
• IP65/IP67 enclosure allowing wet-area and wash-down operation
• 16 bar pressure rating supporting pressurised process loops
• -10 to 70 °C media capability handling cold and warm liquids
• Threaded connection type permitting simple inline replacement
• 30V DC maximum supply enabling low-voltage control-system integration
• IP65/IP67 enclosure allowing wet-area and wash-down operation
• 16 bar pressure rating supporting pressurised process loops
• -10 to 70 °C media capability handling cold and warm liquids
• Threaded connection type permitting simple inline replacement
Applications
• Suitable for metering chemical-dosing lines in processing plants
• Ideal for water distribution and recirculation loops
• Used with OEM skid-mounted equipment requiring compact sensors
• Can be used for HVAC chilled-water flow monitoring
• Suitable for food-processing rinse circuits compatible with stainless wetted parts
• Ideal for water distribution and recirculation loops
• Used with OEM skid-mounted equipment requiring compact sensors
• Can be used for HVAC chilled-water flow monitoring
• Suitable for food-processing rinse circuits compatible with stainless wetted parts
What materials contact the fluid and how does that affect compatibility?
The wetted parts are made from 316L stainless steel, which offers good corrosion resistance for many aqueous and mildly aggressive liquids.
How does the device manage exposure to wash-down conditions?
The enclosure meets IP65 and IP67 levels, providing protection against dust ingress and temporary immersion, enabling use in areas subject to cleaning procedures.
What electrical constraints should be observed during installation?
The transmitter must be supplied at no more than 30V DC and connected following the plants low-voltage wiring standards to ensure proper operation.
What flow and pressure limits define safe operation?
The unit measures flows from 0.2 L/min up to 150 L/min and is rated for process pressures up to 16 bar to match common industrial circuits.
What temperature boundaries apply to the device and the media?
The allowable ambient operating temperature extends down to -10 °C and the media temperature range reaches up to 70 °C for standard applications.
Related links
- Endress+Hauser DMA25 Series Electromagnetic Flowmeter Flow Meter for Liquid 150L/min Max
- Endress+Hauser DMA15 Series Electromagnetic Flowmeter IO-Link Module for Liquid 150L/min Max
- Endress+Hauser DMA20 Series Electromagnetic Flowmeter Flow Meter for Liquid 75L/min Max
- Endress+Hauser DMA15 Series Electromagnetic Flowmeter IO-Link Module for Liquid 750L/min Max
- Endress+Hauser DMA50 Series Electromagnetic Flowmeter Flow Meter for Liquid 750L/min Max
- Endress+Hauser DMA15 Series Electromagnetic Flowmeter IO-Link Module for Liquid 75L/min Max
- Endress+Hauser DMA15 Series Electromagnetic Flowmeter IO-Link Module for Liquid 35L/min Max
- Siemens FM100 Series Electromagnetic Flow Sensor 50L/min Max