Endress+Hauser DMA20 Series Electromagnetic Flowmeter Flow Meter for Liquid, 0.1L/min Min, 75L/min Max
- RS Stock No.:
- 256-6153
- Distrelec Article No.:
- 303-51-192
- Mfr. Part No.:
- DMA20-AAABA1
- Brand:
- Endress+Hauser
Subtotal (1 unit)*
£474.07
(exc. VAT)
£568.88
(inc. VAT)
FREE delivery for orders over £60.00
In Stock
- 13 unit(s) ready to ship
- Plus 17 unit(s) ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | £474.07 |
*price indicative
- RS Stock No.:
- 256-6153
- Distrelec Article No.:
- 303-51-192
- Mfr. Part No.:
- DMA20-AAABA1
- Brand:
- Endress+Hauser
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Endress+Hauser | |
| Media Monitored | Liquid | |
| Product Type | Flow Meter | |
| Device Type | Electromagnetic Flowmeter | |
| Minimum Flow Rate | 0.1L/min | |
| Housing Material | 316L Stainless Steel | |
| Maximum Flow Rate | 75L/min | |
| Connection Type | Thread | |
| Maximum Pressure | 16bar | |
| Minimum Media Temperature | -10°C | |
| Maximum Supply Voltage | 30V dc | |
| IP Rating | IP65, IP67 | |
| Maximum Media Temperature | 70°C | |
| Minimum Operating Temperature | -10°C | |
| Maximum Operating Temperature | 60°C | |
| Standards/Approvals | CE mark | |
| Series | DMA20 | |
| Select all | ||
|---|---|---|
Brand Endress+Hauser | ||
Media Monitored Liquid | ||
Product Type Flow Meter | ||
Device Type Electromagnetic Flowmeter | ||
Minimum Flow Rate 0.1L/min | ||
Housing Material 316L Stainless Steel | ||
Maximum Flow Rate 75L/min | ||
Connection Type Thread | ||
Maximum Pressure 16bar | ||
Minimum Media Temperature -10°C | ||
Maximum Supply Voltage 30V dc | ||
IP Rating IP65, IP67 | ||
Maximum Media Temperature 70°C | ||
Minimum Operating Temperature -10°C | ||
Maximum Operating Temperature 60°C | ||
Standards/Approvals CE mark | ||
Series DMA20 | ||
- COO (Country of Origin):
- FR
Endress+Hauser DMA20 Series Flow Meter, 0.1 L/min Minimum Flow Rate, 16 Bar Maximum Pressure - DMA20-AAABA1
This flow metre is an electromagnetic instrument designed to measure liquid flow in inline, threaded installations. It performs metering duties across a wide flow range and is intended for industrial environments where robust construction and electrical compatibility are required.
Features and Benefits:
• 0.1-75 L/min range allows precise low-to-medium flow measurement
• Withstands up to 16 bar enabling use under moderate pressure
• Operates between -10°C and 70°C handling varying media temperatures
• 316L stainless steel housing resists corrosive process fluids
• IP65 and IP67 ingress protection supports wet and washdown areas
• Accepts up to 30V DC supply for common control systems
• Withstands up to 16 bar enabling use under moderate pressure
• Operates between -10°C and 70°C handling varying media temperatures
• 316L stainless steel housing resists corrosive process fluids
• IP65 and IP67 ingress protection supports wet and washdown areas
• Accepts up to 30V DC supply for common control systems
Applications
• Suitable for municipal water distribution monitoring
• Ideal for chemical dosing and metering lines
• Used with process control cabinets in food processing plants
• Can be used for cooling circuit flow measurement in manufacturing
• Suitable for utility skid installations requiring threaded connections
• Ideal for chemical dosing and metering lines
• Used with process control cabinets in food processing plants
• Can be used for cooling circuit flow measurement in manufacturing
• Suitable for utility skid installations requiring threaded connections
What connection type does it provide for inline mounting?
It uses a threaded connection intended for direct inline coupling to pipework fittings.
What media can be measured with this instrument?
It is intended for liquid media compatible with stainless-steel wetted parts and the specified temperature limits.
How does it cope with washdown and temporary immersion?
The enclosure meets both IP65 and IP67 ratings, offering protection against jets of water and brief submersion.
What electrical supply constraints must be observed?
The device must not be driven above the maximum 30V DC supply rating.
What operational temperature limits apply to ambient and process conditions?
The instrument accepts media and ambient operation down to -10°C and up to 60°C for ambient, with media contact temperature permitted to 70°C.
Related links
- Endress+Hauser DMA20 Series Electromagnetic Flowmeter Flow Meter for Liquid 75L/min Max
- Endress+Hauser DMA15 Series Electromagnetic Flowmeter IO-Link Module for Liquid 75L/min Max
- Endress+Hauser DMA25 Series Electromagnetic Flowmeter Flow Meter for Liquid 150L/min Max
- Endress+Hauser DMA50 Series Electromagnetic Flowmeter Flow Meter for Liquid 750L/min Max
- Endress+Hauser DMA15 Series Electromagnetic Flowmeter IO-Link Module for Liquid 750L/min Max
- Endress+Hauser DMA15 Series Electromagnetic Flowmeter IO-Link Module for Liquid 35L/min Max
- Endress+Hauser DMA15 Series Electromagnetic Flowmeter IO-Link Module for Liquid 150L/min Max
- Key Instruments FR5000 Series Variable Area Flow Meter for Liquid 75L/min Max