Fluke I30S Current Clamp, 30 A DC Max, AC/DC Adapter, 20 A AC Max, Voltage Output, UKAS
- RS Stock No.:
- 653-9879
- Mfr. Part No.:
- I30S
- Brand:
- Fluke
Subtotal (1 unit)*
£907.00
(exc. VAT)
£1,088.40
(inc. VAT)
FREE delivery for orders over £60.00
In Stock
- Plus 9 unit(s) shipping from 04 May 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | £907.00 |
*price indicative
- RS Stock No.:
- 653-9879
- Mfr. Part No.:
- I30S
- Brand:
- Fluke
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Fluke | |
| Adapter Type | AC/DC | |
| Product Type | Current Clamp | |
| Maximum DC Current | 30A | |
| Maximum AC Current | 20A | |
| Accuracy | ±1% + 2 mA | |
| Maximum Conductor Size | 19mm | |
| Cable Length | 2m | |
| Output Type | Voltage | |
| Connector Type | BNC | |
| Battery Type | Alkaline | |
| Battery Life | 30h | |
| Minimum Operating Temperature | 0°C | |
| Maximum Operating Temperature | 50°C | |
| Standards/Approvals | IEC 61326-1 | |
| Model Number | I30S | |
| Calibrated | UKAS | |
| Safety Category Voltage | 300V | |
| Safety Category Level | CAT III | |
| Select all | ||
|---|---|---|
Brand Fluke | ||
Adapter Type AC/DC | ||
Product Type Current Clamp | ||
Maximum DC Current 30A | ||
Maximum AC Current 20A | ||
Accuracy ±1% + 2 mA | ||
Maximum Conductor Size 19mm | ||
Cable Length 2m | ||
Output Type Voltage | ||
Connector Type BNC | ||
Battery Type Alkaline | ||
Battery Life 30h | ||
Minimum Operating Temperature 0°C | ||
Maximum Operating Temperature 50°C | ||
Standards/Approvals IEC 61326-1 | ||
Model Number I30S | ||
Calibrated UKAS | ||
Safety Category Voltage 300V | ||
Safety Category Level CAT III | ||
RoHS Status: Exempt
Fluke Current Clamp, 20A Maximum AC Current, 30A Maximum DC Current - I30S
This current clamp is a Compact Hall-effect probe for non-intrusive measurement of both AC and DC current with suitable recording instruments such as oscilloscopes. It connects via a safety BNC output and is intended for field and bench use within industrial electrical environments up to 300V.
Features & Benefits
• 30mA–30A DC sensitivity delivering precise low-current measurement
• 30mA–20A AC range maintaining accurate alternating current readings
• ±1% of reading ±2mA accuracy ensuring dependable quantitative results
• 100mV/A output providing straightforward voltage-based capture
• 2m cable and safety BNC enabling flexible connection to instruments
• 19mm jaw capacity allowing measurement on Compact conductors
• 30mA–20A AC range maintaining accurate alternating current readings
• ±1% of reading ±2mA accuracy ensuring dependable quantitative results
• 100mV/A output providing straightforward voltage-based capture
• 2m cable and safety BNC enabling flexible connection to instruments
• 19mm jaw capacity allowing measurement on Compact conductors
**Applications**
• Suitable for commissioning and fault diagnosis on control panels
• Ideal for waveform capture with oscilloscopes during motor testing
• Used for in-situ current verification on automation equipment
• Can be used for DC load profiling in battery and power systems
• Used with portable recorders for transient and frequency analysis
• Ideal for waveform capture with oscilloscopes during motor testing
• Used for in-situ current verification on automation equipment
• Can be used for DC load profiling in battery and power systems
• Used with portable recorders for transient and frequency analysis
What supply does it use and how long will it operate on a single cell?
It runs from a single 9V alkaline PP3 cell and provides approximately 30 h of operation with a low-battery indicator.
How does the device handle high-frequency signals?
The sensor responds from DC to 100 kHz with minimal amplitude loss up to that range, supporting measurements of fast transients.
What safety rating and environmental limits apply to its use?
The probe is rated to CAT III 300V and operates between 0°C and +50°C in non-condensing conditions.
How is zero offset managed before taking measurements?
A manual thumbwheel permits fine output zero adjustment to compensate for offset prior to recording.
Warning
Use of the probe on uninsulated conductors is limited to 300 V ac rms or dc and frequencies below 1 kHz.
Supplied with
Alkaline PP3 battery, 4mm shrouded plug adaptor and operators manual.
Related links
- Fluke I30S Current Clamp AC/DC Adapter Voltage Output
- Fluke I30S Current Clamp AC/DC Adapter Voltage Output - RSCAL
- Fluke I1010 Current Clamp AC/DC Adapter Voltage Output - UKAS
- Fluke I410 Current Clamp AC/DC Adapter Voltage Output - UKAS
- Fluke I310S Current Clamp AC/DC Adapter Voltage Output - UKAS
- Chauvin Arnoux Current Clamp AC/DC Adapter Voltage Output - UKAS
- Chauvin Arnoux E27 Current Clamp AC/DC Adapter Voltage Output - UKAS
- Fluke I200S Current Clamp 240 A ac AC Max, Voltage Output - UKAS