Fluke I30S Current Clamp, 30A DC Max, AC/DC Adapter, 20A ac AC Max - RS Calibrated
- RS Stock No.:
- 653-9857
- Mfr. Part No.:
- I30S
- Brand:
- Fluke
Subtotal (1 unit)*
£829.40
(exc. VAT)
£995.28
(inc. VAT)
FREE delivery for orders over £50.00
In Stock
- 4 unit(s) ready to ship
- Plus 4 unit(s) ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
---|---|
1 + | £829.40 |
*price indicative
- RS Stock No.:
- 653-9857
- Mfr. Part No.:
- I30S
- Brand:
- Fluke
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | Fluke | |
Adapter Type | AC/DC | |
Maximum DC Current | 30A | |
Maximum AC Current | 20A ac | |
Best Accuracy | ±1% + 2 mA | |
Resolution | ±1 mA | |
Maximum Conductor Size | 19mm | |
Calibrated | RSCAL | |
Safety Category | CAT III 300V | |
Connector Type | BNC | |
Battery Type | 9 V | |
Maximum Bandwidth | 100kHz | |
Battery Life | 30 h | |
Cable Length Extended | 2m | |
Maximum Operating Temperature | +50°C | |
Model Number p | I30S | |
Minimum Operating Temperature | 0°C | |
Safety Category Level | CAT III | |
Safety Category Voltage | 300V | |
Bandwidth | DC → 100kHz | |
Select all | ||
---|---|---|
Brand Fluke | ||
Adapter Type AC/DC | ||
Maximum DC Current 30A | ||
Maximum AC Current 20A ac | ||
Best Accuracy ±1% + 2 mA | ||
Resolution ±1 mA | ||
Maximum Conductor Size 19mm | ||
Calibrated RSCAL | ||
Safety Category CAT III 300V | ||
Connector Type BNC | ||
Battery Type 9 V | ||
Maximum Bandwidth 100kHz | ||
Battery Life 30 h | ||
Cable Length Extended 2m | ||
Maximum Operating Temperature +50°C | ||
Model Number p I30S | ||
Minimum Operating Temperature 0°C | ||
Safety Category Level CAT III | ||
Safety Category Voltage 300V | ||
Bandwidth DC → 100kHz | ||
RoHS Status: Exempt
- COO (Country of Origin):
- CN
i30s 30A High Resolution, High Bandwidth Oscilloscope Current Probe
The i30 may be used in conjunction with bench and portable oscilloscopes for accurate non-intrusive ac & dc current measurement.,Applications include: inverters, switch mode power supplies, industrial controllers, automotive leakage currents and other applications requiring accurate isolated current measurement.
Hall effect sensing of a.c. and d.c. current
Power LED warns of low battery by flashing
Zero adjust knob to accommodate offsets
The wide, flat frequency response means this probe exhibits a fast response when measuring current pulses
2.0m flying lead terminated with 50Ω BNC plugs
Designed to meet EN61010-1, EN61010-2-032 installation CAT III 300V
Withstands overloads to 500A
Power LED warns of low battery by flashing
Zero adjust knob to accommodate offsets
The wide, flat frequency response means this probe exhibits a fast response when measuring current pulses
2.0m flying lead terminated with 50Ω BNC plugs
Designed to meet EN61010-1, EN61010-2-032 installation CAT III 300V
Withstands overloads to 500A
Warning
Use of the probe on uninsulated conductors is limited to 300 V ac rms or dc and frequencies below 1 kHz.
Supplied with
Alkaline PP3 battery, 4mm shrouded plug adaptor and operators manual.
Fluke AC/DC Current Clamp
Features and Benefits
- Hall effect sensing of AC/DC current
- Current range: 30 mA to 30 A DC, 30 mA to 20 A AC rms
- Usable current range: 5 mA to 30 A DC, 30 mA to 20 A AC rms
- Frequency range: DC to 100 kHz (-0.5 dB)
- Low battery indicator - power LED warns of low battery by flashing
- Zero adjust knob to accommodate offsets
- The wide, flat frequency response means this probe exhibits a fast response when measuring current pulses
- 2 m lead terminated with 50Ω BNC plugs
- Designed to meet EN61010-1, EN61010-2-032 installation CAT III 300V
- Withstands overloads to 500A
- Power supply - 9 V Alkaline, MN1604/PP3, 30 hours
- Maximum conductor size - 19 mm diameter
- Output connection - Safety BNC connector, supplied with safety 4 mm adapter
- Weight - 250g
- Dimensions - 183 mm x 71 mm x 25 mm
Applications
Inverters
Switch mode power supplies industrial controllers
Automotive leakage currents
Applications requiring accurate isolated current measurement
Waveform analysis
Switch mode power supplies industrial controllers
Automotive leakage currents
Applications requiring accurate isolated current measurement
Waveform analysis
Certifications
CAT III 300V
IEC 61010-1
Pollution degree 2
IEC 61010-2-032
IEC 61326-1
CE certified
cCSAus certified
EN61010-1
EN61010-2-032
IEC 61010-1
Pollution degree 2
IEC 61010-2-032
IEC 61326-1
CE certified
cCSAus certified
EN61010-1
EN61010-2-032
Related links
- Fluke I30S Current Clamp AC/DC Adapter, 20A ac AC Max - UKAS Calibrated
- Fluke I30 Current Clamp AC/DC Adapter Current Output
- Fluke I30 Current Clamp AC/DC Adapter Current Output - RS Calibrated
- Fluke I30 Current Clamp AC/DC Adapter Current Output - UKAS Calibrated
- GMC-I Prosys CP- 35 Current Clamp AC/DC Adapter Current Output - RS Calibrated
- GMC-I Prosys CP- 35 Current Clamp AC/DC Adapter Current Output - UKAS Calibrated
- Fluke I30S Current Clamp AC/DC Adapter Voltage Output
- GMC-I Prosys CP- 30 Current Clamp AC/DC Adapter Current Output