Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | SICK | |
Series | UE410 | |
Safety Category | 4 | |
SIL | SIL 3 | |
Supply Voltage | 30 V dc | |
Length | 96.5mm | |
Width | 22.5mm | |
Depth | 120.8mm | |
Select all | ||
---|---|---|
Brand SICK | ||
Series UE410 | ||
Safety Category 4 | ||
SIL SIL 3 | ||
Supply Voltage 30 V dc | ||
Length 96.5mm | ||
Width 22.5mm | ||
Depth 120.8mm | ||
- COO (Country of Origin):
- DE
UE410-MM3 Muting Main Unit and UE410-XM3 Muting Extension
Functions include muting and override, concurrence monitoring, monitoring total muting time, sensor gap monitoring, end of muting by ESPE. Applications: Opto-electronic protective devices and non-contact safety switches
2 or 4 muting sensors
1 reset/restart input and external device monitoring
Activation and time adjustable 0.33 to 60 min
Type of output safety capable outputs: PNP semiconductors, short-circuit protected, cross-circuit monitored
Maximum output current: 2A
Maximum response time: 13 ms
Maximum switch on time: 10 s
Maximum power consumption: 3 W
Category 4 (EN ISO 13849), SIL3 (IEC 61508), SILCL3 (IEC 62061), PL e (EN ISO 13849)
1 reset/restart input and external device monitoring
Activation and time adjustable 0.33 to 60 min
Type of output safety capable outputs: PNP semiconductors, short-circuit protected, cross-circuit monitored
Maximum output current: 2A
Maximum response time: 13 ms
Maximum switch on time: 10 s
Maximum power consumption: 3 W
Category 4 (EN ISO 13849), SIL3 (IEC 61508), SILCL3 (IEC 62061), PL e (EN ISO 13849)
Related links
- SICK UE410 Series Safety Controller, 30 V dc
- SICK UE410 Series Safety Controller, 18 → 30 V dc
- SICK UE410 Series Safety Controller, 24 V dc
- SICK UE410 Series Safety Controller 2 Safety Outputs, 24 V dc
- SICK UE410 Series Safety Controller 4 Safety Outputs, 24 V dc
- SICK UE410 Series Safety Controller 4 Safety Outputs, 24 V dc
- SICK UE410 Series Safety Controller 1 Safety Outputs, 24 V dc
- SICK UE410 Series Safety Controller