Schneider Electric Residual Current Circuit Breaker with Overload Protection, 16 A Current Rating, 1-Pole, 30 mA Trip
- RS Stock No.:
- 654-654
- Mfr. Part No.:
- A9D56616
- Brand:
- Schneider Electric
Subtotal (1 unit)*
£96.66
(exc. VAT)
£115.99
(inc. VAT)
Add 1 unit to get free delivery
In Stock
- 1 unit(s) ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | £96.66 |
*price indicative
- RS Stock No.:
- 654-654
- Mfr. Part No.:
- A9D56616
- Brand:
- Schneider Electric
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Schneider Electric | |
| Current Rating | 16 A | |
| Product Type | Residual Current Circuit Breaker with Overload Protection | |
| Series | A9d | |
| Number of Poles | 1 | |
| Range | Acti9 | |
| Trip Sensitivity | 30mA | |
| Tripping Characteristics | Type B | |
| Terminal Type | Screw Clamp | |
| Width | 18 mm | |
| Depth | 72mm | |
| Height | 110mm | |
| Breaking Capacity | 10000A | |
| Standards/Approvals | IEC 61009-2-2, IEC 61009-1, BS EN 61009-1 | |
| Application | Distribution | |
| Select all | ||
|---|---|---|
Brand Schneider Electric | ||
Current Rating 16 A | ||
Product Type Residual Current Circuit Breaker with Overload Protection | ||
Series A9d | ||
Number of Poles 1 | ||
Range Acti9 | ||
Trip Sensitivity 30mA | ||
Tripping Characteristics Type B | ||
Terminal Type Screw Clamp | ||
Width 18 mm | ||
Depth 72mm | ||
Height 110mm | ||
Breaking Capacity 10000A | ||
Standards/Approvals IEC 61009-2-2, IEC 61009-1, BS EN 61009-1 | ||
Application Distribution | ||
- COO (Country of Origin):
- ES
The Schneider Electric Residual current circuit breaker with overcurrent protection (RCD/MCB) Acti 9 iDPN N Vigi, 6kA (IEC/EN 61009-2-1). 1-pole+N, rated current 16A, characteristic B, earth fault sensitivity 30mA, earth fault protection class Type A, operating voltage (Ue) 230V AC, insulation voltage (Ui) 400V AC. Ensures comprehensive protection of final circuits against overcurrent's and fault currents. Switches and disconnects circuits. Snap action for low-wear switching of the contacts. Mechanically isolated red indicator in case of fault tripping of the miniature circuit breaker or tripping due to a fault current. Clear switch position indication via green marking on the device's switch knob.
Number of protected poles is 1
Neutral position is Left
[In] Rated current is 16 A
Related links
- Schneider Electric RCBO 1P+N Poles Type B, Acti9 Range
- Schneider Electric RCBO 1P Poles Type B, Acti9 Range
- Schneider Electric RCBO 1P+N Poles Type B, Acti9 Range
- Schneider Electric RCBO 1P+N Poles Type B, Acti9 Range