Fluke 8808A Bench Digital Multimeter, True RMS, 10A ac Max, 10A dc Max, 750V ac Max - UKAS Calibrated
- RS Stock No.:
- 415-544
- Mfr. Part No.:
- FLUKE 8808A/SU 240V
- Brand:
- Fluke
Subtotal (1 unit)*
£967.68
(exc. VAT)
£1,161.22
(inc. VAT)
FREE delivery for orders over £50.00
- Plus 21 unit(s) shipping from 17 November 2025
- Plus 9 unit(s) shipping from 20 November 2025
- Plus 11 unit(s) shipping from 24 November 2025
Units | Per unit |
|---|---|
| 1 + | £967.68 |
*price indicative
- RS Stock No.:
- 415-544
- Mfr. Part No.:
- FLUKE 8808A/SU 240V
- Brand:
- Fluke
Select all | Attribute | Value |
|---|---|---|
| Brand | Fluke | |
| Multimeter Type | Bench | |
| Model Number p | 8808A | |
| Display Type | Digital | |
| Functions Measured | AC Current, AC Voltage, Continuity, DC Current, DC Voltage, Diode, Frequency, Resistance | |
| Calibrated | UKAS | |
| Absolute Maximum DC Current Measurement | 10A dc | |
| Absolute Maximum DC Voltage Measurement | 1000V dc | |
| Absolute Maximum AC Current Measurement | 10A ac | |
| Absolute Maximum AC Voltage Measurement | 750V ac | |
| Absolute Maximum Resistance Measurement | 100MΩ | |
| True RMS | Yes | |
| Maximum Frequency | 100kHz | |
| DC Current Measurement Resolution | 0.001µA dc | |
| AC Current Measurement Resolution | 0.1µA ac | |
| AC Voltage Measurement Resolution | 1µV ac | |
| DC Voltage Measurement Resolution | 1µV dc | |
| Resistance Measurement Resolution | 1mΩ | |
| Dimensions | 297 x 217 x 88mm | |
| Best DC Voltage Accuracy | ±0.015% + 0.003 | |
| Length | 297mm | |
| Best Resistance Measurement Accuracy | ±1.75% + 0.004 | |
| Maximum Operating Temperature | +50°C | |
| Weight | 2.1kg | |
| Best AC Voltage Accuracy | ±0.9% + 0.05 Digits | |
| Minimum Operating Temperature | 0°C | |
| Height | 88mm | |
| Width | 217mm | |
| Best DC Current Accuracy | ±0.2% + 0.01 | |
| Best AC Current Accuracy | ±0.5% + 0.12 | |
| Select all | ||
|---|---|---|
Brand Fluke | ||
Multimeter Type Bench | ||
Model Number p 8808A | ||
Display Type Digital | ||
Functions Measured AC Current, AC Voltage, Continuity, DC Current, DC Voltage, Diode, Frequency, Resistance | ||
Calibrated UKAS | ||
Absolute Maximum DC Current Measurement 10A dc | ||
Absolute Maximum DC Voltage Measurement 1000V dc | ||
Absolute Maximum AC Current Measurement 10A ac | ||
Absolute Maximum AC Voltage Measurement 750V ac | ||
Absolute Maximum Resistance Measurement 100MΩ | ||
True RMS Yes | ||
Maximum Frequency 100kHz | ||
DC Current Measurement Resolution 0.001µA dc | ||
AC Current Measurement Resolution 0.1µA ac | ||
AC Voltage Measurement Resolution 1µV ac | ||
DC Voltage Measurement Resolution 1µV dc | ||
Resistance Measurement Resolution 1mΩ | ||
Dimensions 297 x 217 x 88mm | ||
Best DC Voltage Accuracy ±0.015% + 0.003 | ||
Length 297mm | ||
Best Resistance Measurement Accuracy ±1.75% + 0.004 | ||
Maximum Operating Temperature +50°C | ||
Weight 2.1kg | ||
Best AC Voltage Accuracy ±0.9% + 0.05 Digits | ||
Minimum Operating Temperature 0°C | ||
Height 88mm | ||
Width 217mm | ||
Best DC Current Accuracy ±0.2% + 0.01 | ||
Best AC Current Accuracy ±0.5% + 0.12 | ||
RoHS Status: Exempt
- COO (Country of Origin):
- CN
Fluke 8808A Multimeter , 5.5 digit
Large and clear Pass and Fail indication based on user defined limits
Extreme ease of use through soft key menu access, ideal for unskilled operators
5.5 digit resolution with 0.015% basic dc V accuracy,
Dual display to measure different signal characteristics such as Volts and Current simultaneously
Dedicated current ranges to measure dc leakage current (i-Leakage mode)
Math Functions: dBm, dB, Min, Max
Patented split terminal jacks for 2x4 Ohms function for precise 4-wire low ohms measurements.
RS-232 Interface
Programming Languages/Modes: Simplified ASCI, Fluke 45
Safety Rating EN61010-1 CAT I 1000 V, CAT II 600 V
Note
Supplied with
FLUKE Multimeter, 20Hz To 1MHz Frequency Measurement, 1,000V DC Maximum Input - 8808A 240V
Features & Benefits
• Front-panel setup key allows for quick single-key access to saved setups
• Compatible with commonly used power distribution standards, for versatility
• Low-impedance amplifier and current-to-voltage conversion technique, offering accurate low-current leakage detection
Applications
• Laboratory-based engineers
• Factories and workshops
Is this multimeter portable?
Related links
- Fluke 8808A Bench Digital Multimeter 10A ac Max 750V ac Max - RS Calibrated
- Fluke calibration 8808A/SU Bench Digital Multimeter 10A ac Max 1000V ac Max
- Fluke calibration 8808A/TL 240V Bench Digital Multimeter 10A ac Max 750V ac Max
- Fluke calibration 8808A/SU 240V Bench Digital Multimeter 10A ac Max 1000V ac Max - UKAS
- Fluke calibration 8808A Bench Digital Multimeter 10A ac Max 750V ac Max
- Fluke calibration 8808A/SU 240V Bench Digital Multimeter 10A ac Max 1000V ac Max - RS Calibrated
- RS PRO IDM8341 Bench Digital Multimeter 10A ac Max 750V ac Max - UKAS Calibrated
- BK Precision 5492CGPIB Bench Digital Multimeter 10A ac Max 750V ac Max - UKAS Calibrated