Druck DPI 880 Multi-Function Calibrator, 55 mA, 30V 50 mm 180 mm 85mm
- RS Stock No.:
- 532-7530
- Mfr. Part No.:
- I880
- Brand:
- Druck
Subtotal (1 unit)*
£2,642.58
(exc. VAT)
£3,171.10
(inc. VAT)
FREE delivery for orders over £60.00
In Stock
- 7 unit(s) ready to ship
- Plus 1 unit(s) ready to ship from another location
- Plus 4 unit(s) shipping from 02 December 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | £2,642.58 |
*price indicative
- RS Stock No.:
- 532-7530
- Mfr. Part No.:
- I880
- Brand:
- Druck
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Druck | |
| Product Type | Multi-Function Calibrator | |
| Maximum Voltage Measurement | 30V | |
| Accuracy | ±0.05 % | |
| Maximum Pressure Measurement | 700bar | |
| Port Connections | 4 mm Socket | |
| Battery Life | 50h | |
| Maximum Current Measurement | 55mA | |
| Battery Type | AA | |
| Power Source | Battery | |
| Safety Category Level | CAT III | |
| Minimum Operating Temperature | -10°C | |
| Maximum Operating Temperature | 50°C | |
| Hazardous Area Certification | No | |
| Weight | 425g | |
| Width | 85mm | |
| Height | 50mm | |
| Standards/Approvals | IEC 584, CE, BS EN 61010:2001, BS EN 61326-1:1998 + A2:2001, DIN 43710 | |
| Length | 180mm | |
| Model Number | DPI 880 | |
| Select all | ||
|---|---|---|
Brand Druck | ||
Product Type Multi-Function Calibrator | ||
Maximum Voltage Measurement 30V | ||
Accuracy ±0.05 % | ||
Maximum Pressure Measurement 700bar | ||
Port Connections 4 mm Socket | ||
Battery Life 50h | ||
Maximum Current Measurement 55mA | ||
Battery Type AA | ||
Power Source Battery | ||
Safety Category Level CAT III | ||
Minimum Operating Temperature -10°C | ||
Maximum Operating Temperature 50°C | ||
Hazardous Area Certification No | ||
Weight 425g | ||
Width 85mm | ||
Height 50mm | ||
Standards/Approvals IEC 584, CE, BS EN 61010:2001, BS EN 61326-1:1998 + A2:2001, DIN 43710 | ||
Length 180mm | ||
Model Number DPI 880 | ||
RoHS Status: Exempt
- COO (Country of Origin):
- GB
Druck Multi-Function Calibrator, 30V Maximum Voltage Measurement, 700 bar Maximum Pressure Measurement - I880
This multi-function calibrator supplies precise pressure, voltage and current reference signals for field and workshop verification of instrumentation. It is designed for portable use across a broad ambient range and operates from standard AA batteries, enabling maintenance and calibration tasks where mains supply is unavailable. The unit includes standard 4mm socket connections and meets recognised international test standards to support routine calibration procedures in industrial environments.
Features and Benefits:
• ±0.05% accuracy ensures precise measurement and generation
• 55mA maximum current measurement supports loop testing
• 700bar maximum pressure measurement handles high-pressure systems
• 30V maximum voltage measurement enables sensor and transmitter checks
• 50h battery life allows extended field use on AA cells
• 55mA maximum current measurement supports loop testing
• 700bar maximum pressure measurement handles high-pressure systems
• 30V maximum voltage measurement enables sensor and transmitter checks
• 50h battery life allows extended field use on AA cells
Applications
• Suitable for commissioning pressure transmitters and sensors
• Ideal for on-site voltage source verification of instruments
• Used for field loop calibration and maintenance tasks
• Can be used for periodic checks in industrial control systems
• Used with portable test benches for diagnostics and adjustment
• Ideal for on-site voltage source verification of instruments
• Used for field loop calibration and maintenance tasks
• Can be used for periodic checks in industrial control systems
• Used with portable test benches for diagnostics and adjustment
What environmental range can this device operate within?
It functions reliably from -10°C to 50°C.
How is the unit powered and how long will it run between replacements?
It runs on AA batteries and offers approximately 50 h of operation per set.
What safety category does it meet for electrical measurements?
The instrument is rated to CAT III for electrical measurement safety.
What are the physical connection options for attaching test leads?
Connections are provided via standard 4mm sockets for common test leads.
Related links
- Druck DPI 880 Multi-Function Calibrator 30V 50 mm 180 mm 100mm, RSCAL
- Druck Genii IS Multi-Function Calibrator 30 V dc, 300V ac 183 mm 96 mm 200mm
- Druck DPI620G-IS Multi-Function Calibrator 1000V ac/dc 183 mm 61 mm 130mm, RSCAL
- Druck DPI620G-IS Multi-Function Calibrator 1000V ac/dc 183 mm 61 mm 130mm, UKAS
- Druck DPI620G-IS Multi-Function Calibrator 1000V ac/dc 183 mm 61 mm 130mm
- Druck Genii IS Multi-Function Calibrator 30 V dc RSCAL
- Druck Genii IS Multi-Function Calibrator 30 V dc UKAS
- Fluke 789 Multi-Function Calibrator 1000V ac 50 mm 203 mm 100mm