Castle Sonus GA116i Class 1 Sound Level Meter, 35dB to 140dB, 20kHz max with RS Calibration
- RS Stock No.:
- 908-5173
- Mfr. Part No.:
- 01GA116i
- Brand:
- Castle
Subtotal (1 unit)*
£1,235.00
(exc. VAT)
£1,482.00
(inc. VAT)
FREE delivery for orders over £50.00
In Stock
- 1 unit(s) ready to ship
- Plus 1 unit(s) shipping from 18 November 2025
- Plus 999,999,997 unit(s) shipping from 28 November 2025
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
---|---|
1 + | £1,235.00 |
*price indicative
- RS Stock No.:
- 908-5173
- Mfr. Part No.:
- 01GA116i
- Brand:
- Castle
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | Castle | |
Maximum Sound Level | 140dB | |
Minimum Sound Level | 35dB | |
Resolution | 0.1 dB | |
Accuracy Class | IEC 61672-1:2002 Class 1 | |
DOSE Measurement | Yes | |
Weighting | A, C | |
Display Type | LCD | |
Battery Type | 9V PP3 | |
Calibrated | RSCAL | |
Fast/Slow Time Averaging | Both | |
Data Logging | No | |
Interface Type | USB | |
Maximum Frequency | 20kHz | |
Maximum Operating Temperature | +50°C | |
Minimum Frequency | 20 Hz | |
Model Number p | Sonus GA116i Class 1 | |
Minimum Operating Temperature | -10°C | |
Select all | ||
---|---|---|
Brand Castle | ||
Maximum Sound Level 140dB | ||
Minimum Sound Level 35dB | ||
Resolution 0.1 dB | ||
Accuracy Class IEC 61672-1:2002 Class 1 | ||
DOSE Measurement Yes | ||
Weighting A, C | ||
Display Type LCD | ||
Battery Type 9V PP3 | ||
Calibrated RSCAL | ||
Fast/Slow Time Averaging Both | ||
Data Logging No | ||
Interface Type USB | ||
Maximum Frequency 20kHz | ||
Maximum Operating Temperature +50°C | ||
Minimum Frequency 20 Hz | ||
Model Number p Sonus GA116i Class 1 | ||
Minimum Operating Temperature -10°C | ||
- COO (Country of Origin):
- GB
Castle GA116i Sonus Class 1 Integrating Sound Level Meter
The GA116i is designed for industrial safety officers, safety managers and engineers, for compliance with the Control of Noise at Work regulations 2005. It is fully compliant with European and International standards. The GA116i will provide all necessary sound measurement information for completing noise at work risk assessments.
Simultaneous measurement of Lp, Leq, Lmax, Cpeak, Lep,d, LAE, Dose, Dose / Hour, Pa2H
'A' and 'C' frequency weighting (toggle)
'Slow' and 'Fast' Time constants (toggle)
Sound pressure (Lp) to 0.1dB resolution
Integrated equivalent level (Leq) measurement
Personal sound exposure level (Lep,d)
Single event sound exposure level (LAE)
Noise dose%, noise dose per hour%, pascal squared hours
Lmax - maximum Lp (rms) level
Cpeak - maximum C weighted peak level
Elapsed time (running time hrs, min, sec)
Over Load and Under Range indication
Housed in tough, crack-resistant ABS plastic
'A' and 'C' frequency weighting (toggle)
'Slow' and 'Fast' Time constants (toggle)
Sound pressure (Lp) to 0.1dB resolution
Integrated equivalent level (Leq) measurement
Personal sound exposure level (Lep,d)
Single event sound exposure level (LAE)
Noise dose%, noise dose per hour%, pascal squared hours
Lmax - maximum Lp (rms) level
Cpeak - maximum C weighted peak level
Elapsed time (running time hrs, min, sec)
Over Load and Under Range indication
Housed in tough, crack-resistant ABS plastic
Standards
IEC 61672-1:2002 Class 1, IEC 60651: 1979 Type 1, IEC 60804: 2001 Type 1
Castle Sonus i, Class 1 Leq Sound Level Meter
The SONUS i (GA116i) is a Class 1 sound level meter and is designed for industrial safety officers, safety managers and engineers, for compliance with the Control of Noise at Work regulations 2005. It is fully compliant with European and International standards. The SONUS i will provide all necessary sound measurement information for completing noise at work risk assessments.
Simultaneous measurement of Lp, Leq, Lmax, Cpeak, Lep,d, LAE, Dose, Dose / Hour, Pa2H
'A' and 'C' frequency weighting (toggle)
'Slow' and 'Fast' Time constants (toggle)
Housed in tough, crack-resistant ABS plastic
'A' and 'C' frequency weighting (toggle)
'Slow' and 'Fast' Time constants (toggle)
Housed in tough, crack-resistant ABS plastic
The simultaneous measurement of LAeq and LCPeak makes the SONUS I ideal for measurements to The Control of Noise at Work Regulations 2005, which requires both these measurements. The SONUS i can also measure the 'C' weighted Leq values, which can be used for hearing protection assessments to the regulations.
Standards
IEC 61672-1:2002 Class 1, IEC 60651: 1979 Type 1, IEC 60804: 2001 Type 1
Standards
IEC 61672-1:2002 Class 1, IEC 60651: 1979 Type 1, IEC 60804: 2001 Type 1
Sound pressure (Lp) to 0.1dB resolution
Integrated equivalent level (Leq) measurement
Personal sound exposure level (Lep,d)
Single event sound exposure level (LAE)
Noise dose%, noise dose per hour%, pascal squared hours
Lmax - maximum Lp (rms) level
Cpeak - maximum C weighted peak level
Elapsed time (running time hrs, min, sec)
Over Load and Under Range indication
Integrated equivalent level (Leq) measurement
Personal sound exposure level (Lep,d)
Single event sound exposure level (LAE)
Noise dose%, noise dose per hour%, pascal squared hours
Lmax - maximum Lp (rms) level
Cpeak - maximum C weighted peak level
Elapsed time (running time hrs, min, sec)
Over Load and Under Range indication
Related links
- Castle Sonus GA116i Class 1 Sound Level Meter 20kHz max
- Castle Sonus GA116E Class 1 Datalogging Sound Level Meter 20kHz max with RS Calibration
- Castle Sonus GA216L Class 2 Datalogging Sound Level Meter 20kHz max
- Castle Sonus GA116L Class 1 Datalogging Sound Level Meter 20kHz max
- Castle dBAir GA141S Class 1 Datalogging Sound Level Meter 20kHz max with RS Calibration
- Castle dBAir GA141SO Class 1 Datalogging Sound Level Meter 20kHz max with RS Calibration
- Castle Sonus GA216L Class 2 Datalogging Sound Level Meter 20kHz max with RS Calibration
- Castle dBAir GA141SO Class 1 Datalogging Sound Level Meter 20kHz max