Ruland Collar, One Piece, Clamp Screw, Bore 26mm, OD 48mm, W 15mm, 1215 Lead-Free Carbon Steel
- RS Stock No.:
- 604-596
- Mfr. Part No.:
- FHT-MCL-26-F
- Brand:
- Ruland
Subtotal (1 unit)*
£29.84
(exc. VAT)
£35.81
(inc. VAT)
FREE delivery for orders over £50.00
Temporarily out of stock
- 999,999,999 unit(s) shipping from 06 November 2025
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
---|---|
1 + | £29.84 |
*price indicative
- RS Stock No.:
- 604-596
- Mfr. Part No.:
- FHT-MCL-26-F
- Brand:
- Ruland
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | Ruland | |
Shaft Diameter | 26mm | |
One/Two Piece | One Piece | |
Material | 1215 Lead-Free Carbon Steel | |
Single/Double Wide | Single | |
Outside Diameter | 48mm | |
Fastening | Clamp Screw | |
Width | 15mm | |
Select all | ||
---|---|---|
Brand Ruland | ||
Shaft Diameter 26mm | ||
One/Two Piece One Piece | ||
Material 1215 Lead-Free Carbon Steel | ||
Single/Double Wide Single | ||
Outside Diameter 48mm | ||
Fastening Clamp Screw | ||
Width 15mm | ||
- COO (Country of Origin):
- US
RS PRO Parallel Circuit Heating Tape for Frost Protection
7581600
Features and Benefits:
Cut to length - the outer sheath is notched on alternate sides at 1 metre intervals to indicate cutting points
Flexible - can be wrapped around pipes
Various lengths available - 20m, 50m or 100m
Voltage ratings either 110 V or 240 V
Constant wattage heating cables
Flexible - can be wrapped around pipes
Various lengths available - 20m, 50m or 100m
Voltage ratings either 110 V or 240 V
Constant wattage heating cables
Typical Applications:
Trace heating cables are electric heating elements designed to provide focused and controllable heat used to prevent pipes, outdoor taps and gutters from freezing, or to maintain a desired temperature on pipes to keep liquids moving.
· For use for internal or external temperature maintenance applications
· Freeze protection
· Water, oil and chemical lines
· Sprinkler system mains
· Supply piping
· Not for use in hazardous areas
· For use for internal or external temperature maintenance applications
· Freeze protection
· Water, oil and chemical lines
· Sprinkler system mains
· Supply piping
· Not for use in hazardous areas
FAQs
When is trace heating required?
Trace heating cable systems are ideal for protecting pipes from freezing, maintaining the temperature of a hot water system and maintaining process temperatures for smooth and efficient running of process plant equipment.
Why RS PRO?
RS PRO is our own brand range and brings you a wide range of high-quality, great value products offering you more choice. Trusted by engineers all over the world, every part of every RS PRO product has been rigorously tested against demanding industry standards; theyre only given the RS PRO Seal of Approval if were confident of their exceptional quality, which means you can be confident too.
When is trace heating required?
Trace heating cable systems are ideal for protecting pipes from freezing, maintaining the temperature of a hot water system and maintaining process temperatures for smooth and efficient running of process plant equipment.
Why RS PRO?
RS PRO is our own brand range and brings you a wide range of high-quality, great value products offering you more choice. Trusted by engineers all over the world, every part of every RS PRO product has been rigorously tested against demanding industry standards; theyre only given the RS PRO Seal of Approval if were confident of their exceptional quality, which means you can be confident too.
Standards
BS EN 62395-1:2006
The Ruland One piece shaft collar has tapped holes for mounting shaft collars to sprockets, pulleys, metallic plates, or other components. Tapped holes allow for a secure connection between the shaft collar and mated component. The clamp style design does not mar the shaft, is easy to remove, and is indefinitely adjustable. Equipment manufacturers benefit from the tightly controlled face to bore perpendicularity (TIR of ≤ .05mm). Perpendicularity is critical for alignment when the shaft collar is used as a load bearing face, mechanical stop, or for mounting components such as gears or bearings.
RoHS3 and REACH compliant
Forged screws test beyond DIN 912 12.9 standards
Machined from solid bar stock to a fine burr free finish
Forged screws test beyond DIN 912 12.9 standards
Machined from solid bar stock to a fine burr free finish
Related links
- Ruland Collar Clamp Screw OD 48mm 1215 Lead-Free Carbon Steel
- Ruland Collar Clamp Screw OD 48mm 1215 Lead-Free Carbon Steel
- Ruland Collar Clamp Screw OD 48mm Stainless Steel
- Ruland Collar Clamp Screw OD 48mm Anodised Aluminium
- Ruland Shaft Collar Clamp OD 40mm 1215 Lead-Free Carbon Steel
- Ruland Collar Clamp Screw OD 57mm 1215 Lead-Free Carbon Steel
- Ruland Collar Clamp Screw OD 57mm 1215 Lead-Free Carbon Steel
- Ruland Collar Clamp Screw OD 60mm 1215 Lead-Free Carbon Steel