Schneider Electric Preventa XPS AF Safety Relay 24V ac/dc, Single/Dual-Channel 3 Safety Contacts

Unavailable
RS will no longer stock this product.

Alternative

This product is not currently available. Here is our alternative recommendation.

RS Stock No.:
360-4346
Mfr. Part No.:
XPSAF5130
Brand:
Schneider Electric
Find similar products by selecting one or more attributes.
Select all

Brand

Schneider Electric

Supply Voltage

24V ac/dc

Number of Channels

1, 2

Safety Contacts

3

Function

Safety Switch/Interlock

Range

Preventa

Safety Category ISO 13849-1

4

PL ISO 13849-1

e

SIL IEC 61508

3

Terminal Type

Screw

Configurable

Yes

Standards Met

CSA, UL Listed

Width

22.5mm

Safety Category

3, 4

Series

XPS AF

Depth

114mm

Performance Level

e

Length

99mm

RoHS Status: Exempt

Schneider Electric | Preventa XPSAF Series | Safety Relays


Simple and effective safety monitoring has never been more crucial in today's highly automated world. Prevention is key to site safety, that's why Schneider Electric offers a Safety Relay in the form of the 'Preventa XPSAF' module that is second to none. Being able to monitor faults with devices along a circuit has the power to stop emergency situations from even occurring.

Features and benefits:


• Single-channel with 3 N/O safety outputs

• Monitoring of a movable guard, with emergency stop monitoring 1 or 2 channel wiring usable.

• Configurable type of start is readily available for the type of activation you wish for your circuit.

• Monitoring of single safety functions, providing an automated solution for use with applications such as emergency push stop buttons or switches.

• Unlimited synchronisation between time inputs.

• Slin in design, with just 22.5mm of width meaning it can fit nicely even in space constraint spaces.

• Accepts cable up to 2.5mm²

• Symmetrical DIN rail support, offering flexible and versatile safety system installation.

• Local signalling in the form of LEDs.

Protection ratings & Safety features (see datasheet for specifics) -

• Impressive line resistance is available, varying between 90 to 100 Ohm (Ω).

• Input protection type is internal, electronic.

• EN1088/ISO 14119, EN 60204-1, EN/IEC 60947-5-1, EN/ISO 13850

• CSA, TUV & UL listed

• IP 40 (enclosure) for protection against small objects up to 1mm such as tools, wires and small wires.

• IP 20 (terminals) for protection against solid objects such as fingers, smaller tools up to 12mm.

• -25 to 60°C temperature range for operation, suitable in varying levels of heat/freezing temperatures.

Applications -


All dangerous machinery requires an automated solution to prevent harm to immediate users and also prevent damage to the machinery. Below are some of the safety applications

• Coded Magnetic Switch (CMS) to prevent tampering by unauthorised users.


• Time delay input if needed allowing you to set up your own time function.

• Light curtains / Two-hand control safety circuits

• Sensing mats and edges

Standards

IEC 204-1; EN 292; EN 418; EN 60204-1; EN 1088

Approvals

BG, UL, CSA

Schneider Electric Safety Relay, DIN Rail Mounting, 24V AC/DC Supply Voltage - Preventa XPSAF Series - XPSAF5130


Reduce the risk of damage when running your industrial equipment with this safety relay from Schneider Electric. It monitors your system and brings it to a halt in the event of a hazard, helping to prevent accidents. Thanks to a maximum input response time of just 40ms, this piece of kit has a lightning-quick reaction to emergency situations. It snaps right onto your DIN rail, so you can install it in a jiffy without the need for any tools. Thanks to its light weight of 250g, you can rest assured that it won't place too much strain on your equipment.

Features & Benefits


• Rated impulse withstand voltage of 4kV means it handles sudden power spikes without suffering damage
• Performs reliably at temperatures between -25°C and +60°C for use in challenging conditions
• Three LED indicators make status monitoring a walk in the park

Applications


• Plant automation
• Automotive repair
• Chemical laboratories

How long will this relay last?


This unit has a mean time to failure of 243 years, so you can count on it to stay the course.

Related links