Schneider Electric Preventa XPS DM 2 Auxiliary Contacts Safety Relay 24V dc, Single Channel 2 Safety Contacts

Currently unavailable
We don’t know if this item will be back in stock, it is being discontinued by the manufacturer.

Alternative

This product is not currently available. Here is our alternative recommendation.

Each

£309.33

(exc. VAT)

£371.20

(inc. VAT)

RS Stock No.:
814-6949
Mfr. Part No.:
XPSDME1132P
Brand:
Schneider Electric
Find similar products by selecting one or more attributes.
Select all

Brand

Schneider Electric

Supply Voltage

24V dc

Number of Channels

1

Safety Contacts

2

Function

Safety Switch/Interlock

Auxiliary Contacts

2

Reset Method

Monitored

Range

Preventa

Safety Category ISO 13849-1

4

Terminal Type

Screw

Series

XPS DM

Width

45mm

Depth

114mm

Length

99mm

Schneider Electric Preventa XPS-DM Safety Relays.


From Schneider Electric this is the Preventa XPSDM series of safety relays and safety modules designed for guard monitoring coded magnetic safety switches. The safety relays have 2 safety outputs and 2 solid state outputs signalling to the process PLC. Front facing LEDs allow you to monitor the circuit status. XPSDM Safety relays also monitor 2 independent sensors plus if you need to monitor more magnetic switches they can be connected in series parallel.

Safety relays from the XPSDM (XPSDMB….P) series include removable terminal blocks providing maximum machine maintenance.

Features & Benefits


  • Created and designed for guard monitoring, this range of XPS-DM safety relays are predominantly used for monitoring XCS-DMC and XCS-DMP coded magnetic safety switches.

  • When the XCS-DM safety switch is used in conjunction with the XPS-DM safety relay, together they offer a certified safety solution for guard monitoring

  • This range of safety relays allowed for multi-switch monitoring to Safety Category 4 solutions which is in accordance with EN954-1/ISO 13849-1

  • The XPS-DMB has the capabilities to monitor 2 independent sensors and modules whilst the XPS-DME can monitor 6 independent sensors and modules

  • 2 safety outputs and 2 solid-state outputs for signalling to the process PLC

  • LEDs are positioned on the front face which provides signalling information on the monitoring circuit status.

Safety Level (Maximum).


  • PL e/Category 4 conforming to EN/ISO 13849-1 b.

  • SILCL 3 conforming to EN/IEC 62061.

Certification.


  • UL, CSA, TUV.