Allen Bradley 1492-RCDA RCD, 25A, 3+N Pole, 30mA, Type A

Subtotal (1 unit)*

£126.59

(exc. VAT)

£151.91

(inc. VAT)

Add to Basket
Select or type quantity
In Stock
  • Plus 4 unit(s) shipping from 27 October 2025
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units
Per unit
1 +£126.59

*price indicative

RS Stock No.:
136-8589
Mfr. Part No.:
1492-RCDA4A25
Brand:
Allen Bradley
Find similar products by selecting one or more attributes.
Select all

Brand

Allen Bradley

Circuit Breaker Type

RCD

Current Rating

25A

Number of Poles

3+N

Trip Sensitivity

30mA

Tripping Characteristics

Type A

Series

1492-RCDA

Rated AC Voltage

230 V, 400V

Mounting Style

DIN Rail Mount

Overall Length

70mm

Overall Depth

75mm

Overall Width

88mm

Terminal Contact Type

Screw

Reset Actuator Type

Toggle Switch

Overall Dimensions

70 x 88 x 75mm

Breaking Capacity at Maximum Voltage Rating

1 (Residual) kA, 10 (Short-Circuit) kA

COO (Country of Origin):
IT

1492 Series


Allen Bradley general purpose RCDs from the 1492 series. The RCDs have a Type A tripping characteristic and an instantaneous break time. 2 or 4 pole versions available. All the RCDs incorporate screw terminals and can be DIN Rail mounted.

Features & Benefits


2 or 4 pole versions
DIN Rail mount
Screw Terminals

Allen Bradley Type A RCD Switch, 25A Current Rating, 30mA Trip Sensitivity - 1492-RCDA4A25


Looking for reliable earth-fault protection? Choose this residual current device (RCD) switch from Rockwell Automation's Allen Bradley range. A 4-pole setup means it's designed to handle 3-phase circuits with live and neutral wires. It works by monitoring the current flow into the circuit and cutting power when it detects an earth fault, protecting your equipment from damage and reducing the risk of injury to personnel. A thermoplastic housing is durable, impact-resistant and suitable for use in harsh environments. You'll find devices like this used on the control panels of industrial machinery.

• Robust electrical endurance of 10,000 operations for long-lasting performance
• Trip sensitivity of 30mA for a fast response to faults
• Toggle switch reset to easily restart the device when a fault is cleared
• Wide operating temperature range of -25°C to +55°C for use in demanding environments

Standards and Certifications


• RoHS (Restriction of Hazardous Substances)
• IEC (International Electrotechnical Commission)

How can I tell the operating status of this RCD switch?


This RCD switch has an indicator window that displays red for ON and green for OFF, making it simple to determine its operating status at a glance.


Allen Bradley RCBs

Related links