Eaton RCBO, 16A Current Rating, 1P+N Poles, 30mA Trip Sensitivity, Type B, PXK Range
- RS Stock No.:
- 183-3540
- Distrelec Article No.:
- 303-96-434
- Mfr. Part No.:
- 236948 PXK-B16/1N/003-A
- Brand:
- Eaton
Subtotal (1 unit)*
£64.27
(exc. VAT)
£77.12
(inc. VAT)
FREE delivery for orders over £50.00
In Stock
- Plus 47 unit(s) shipping from 22 October 2025
- Plus 21 unit(s) shipping from 28 October 2025
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
---|---|
1 + | £64.27 |
*price indicative
- RS Stock No.:
- 183-3540
- Distrelec Article No.:
- 303-96-434
- Mfr. Part No.:
- 236948 PXK-B16/1N/003-A
- Brand:
- Eaton
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | Eaton | |
Current Rating | 16A | |
Number of Poles | 1P+N | |
Trip Sensitivity | 30mA | |
Tripping Characteristics | Type B | |
Range | PXK | |
Circuit Breaker Type | RCD | |
Rated AC Voltage | 240V | |
Mounting Style | DIN Rail Mount | |
Earth Leakage Protection Type | A | |
Overall Dimensions | (L) 80 x (H) 75 x (W) 35mm | |
Overall Length | 80mm | |
Breaking Capacity at Maximum Voltage Rating | 10 kA | |
Overall Depth | 80mm | |
Overall Width | 35mm | |
Application | Commercial, Residential | |
Select all | ||
---|---|---|
Brand Eaton | ||
Current Rating 16A | ||
Number of Poles 1P+N | ||
Trip Sensitivity 30mA | ||
Tripping Characteristics Type B | ||
Range PXK | ||
Circuit Breaker Type RCD | ||
Rated AC Voltage 240V | ||
Mounting Style DIN Rail Mount | ||
Earth Leakage Protection Type A | ||
Overall Dimensions (L) 80 x (H) 75 x (W) 35mm | ||
Overall Length 80mm | ||
Breaking Capacity at Maximum Voltage Rating 10 kA | ||
Overall Depth 80mm | ||
Overall Width 35mm | ||
Application Commercial, Residential | ||
- COO (Country of Origin):
- AT
Eaton RCD, 16 A, Type B - PXK-B Series - PXK-B16/1N/003-A
Protect yourself and your electrical equipment from short circuits, surges and current overload with this Eaton RCD (residual current device). When the breaker detects any current imbalances – which can indicate a serious shock hazard – it isolates the circuit and cuts off the electricity. This quick action prevents shocks to operators and damage to equipment. Attach a breaker to each circuit so that a fault in one won't stop the other circuits from functioning.
• Breaking capacity at maximum voltage rating of 10 kA for safety
• Current rating of 16 A and AC voltage of 240 V for versatile use
• Switchgear suitable for domestic and commercial application
• Current rating of 16 A and AC voltage of 240 V for versatile use
• Switchgear suitable for domestic and commercial application
How much current is needed to trip this circuit breaker?
A trip sensitivity of 30 mA and type B tripping mean it breaks at a current of 120 to 150 mA within 40 milliseconds. This rates as high sensitivity.
How does this circuit breaker detect current leakage?
This unit detects small stray voltages by measuring the current on the circuit's supply and return conductors. It also features Type-A earth leakage protection, meaning it breaks the circuit for sinusoidal and alternating residual currents along with pulsed, DC residual currents that reach dangerous levels, for greater safety.
Note
Eaton formerly known as Moeller
Related links
- Eaton RCBO 1P + N Poles Type B, xPole Range
- Eaton RCBO 1P + N Poles Type B, xPole Range
- Eaton RCBO 1P+N Poles Type B, PXK Range
- Eaton RCBO 1P+N Poles Type B, PXK Range
- Eaton RCBO 1P+N Poles Type B, PXK Range
- Eaton RCBO 1+N Poles Type B, xEffect Range
- Eaton RCBO 1P+N Poles Type C, PXK Range
- Eaton RCBO 2P Poles Type A FRBdM Range