Testec TT-SI 9002 Oscilloscope Probe, Probe Type: Active, Differential 25MHz 1kV 1:20, 1:200

  • RS Stock No. 224-1225
  • Mfr. Part No. SI-9002
  • Brand Testec
Technical Reference
Legislation and Compliance
RoHS Status: Not Applicable
COO (Country of Origin): TW
Product Details

Differential probes SI-9001, SI-9002

When you use the oscilloscope in its usual context to show and measure circuit shaft formations, you are working in the most common mode for voltage measurements. The differential probe enhances the oscilloscope probe's measuring capabilities with performance conversion, inverters, motor speed indicators, switch mode power supplies and many other applications.

  1:10 / 1:100
SI-9001
01:20 / 1:200
SI-9002
Bandwidth DC → 25 MHz (-3 dB) DC → 25 MHz (-3 dB)
Accuracy ±2% ±2%
Rise time 14 ns 14 ns
Input 4 M Ω / 10 pF respectively 4 M Ω / 10 pF respectively
impedance for mass for mass
Input voltage    
-Max. difference ±70 V (DC + AC probes) or
50 V rms for 1//10 ratio
±700 V (DC + AC probes) or
500 V rms for 1//100 ratio
±140V (DC + AC probes) or
100 V rms for 1/20 ratio
±1400 V (DC + AC probes) or
1000 V rms for 1//200 ratio
-Max. common
mode
±700 V (DC + AC probes)
or 500 V rms for 1//10 or 1//100 ratio
±1400 V (DC + AC probes)
or 1000 V rms for 1//20 or 1//200
Absolute max. ±1400 V (DC+ ±1400 V (DC+
Voltage AC probes) or AC probes) or
(Differential or 1000 V rms for 1//10 1000 V rms for 1//20
common or 1//100 or 1/200
mode) ratio ratio
Output voltage    
-Max. Amplitude ± 7 V (at 2 KΩ ± 7 V (at 2 KΩ
  load) load)
-Offset (typical) ±5 mV, -10°C → +40°C ±5 mV, -10°C → +40°C
-Interference: 1.5 → 2 mV 1.5 → 2 mV
(typical)    
-Source impedance 1 Ω at 1 kHz, 1 Ω at 1 kHz,
(typical) 8 Ω at 1 MHz 8 Ω at 1 MHz
CMRR (typical) 50 Hz: -86 dB;
20 KHz: -66 dB
200 kHz: -56 dB
50 Hz: -86 dB; 20 KHz: -66 dB
200 kHz: 56 dB
Ambient -10 °C → +40 °C -10 °C → +40 °C
operating temperature    
Ambient -30 °C → +70 °C -30 °C → +70 °C
storage temperature    
Ambient 25 → 85% RH 25 → 85% RH
operating humidity    
Ambient 25 → 85% RH 25 → 85% RH
storage humidity    
Energy consumption 4 x AA batteries or
6 Vdc / 60 mA
Power adapter
(not
included)
4 x AA batteries or
6 Vdc / 60 mA
Power adapter
(not
included)
Length of 45 cm 45 cm
entry cable    
Length of BNC 95 cm (RG58/U) 95 cm (RG58/U)
Cable    
Weight 285 g 285 g
Dimensions 168 x 62 x 20 mm 168 x 62 x 20 mm
(L x W x H) (6.6" x 2.4" x 0.8") (86.6" x 2.4" x 0.8")
Specifications
Attribute Value
Probe Type Active, Differential
Attenuation 1:20, 1:200
Bandwidth 25MHz
Maximum Common Mode Input Voltage 1kV
Model Number p TT-SI 9002
Safety Category Level CAT III
Safety Category Voltage 1000 V ac, 1400 V ac/dc
Series SI
Safety Category CAT III 1000 V ac, CAT III 1400 V
Rise Time 14ns
19 In stock for delivery within 1 working days
Price Each
£ 262.17
(exc. VAT)
£ 314.60
(inc. VAT)
Units
Per unit
1 +
£262.17
Related Products
Rated voltage of probe:. Highly flexible 1.2m coaxial ...
Description:
Rated voltage of probe:. Highly flexible 1.2m coaxial cable with BNC plugCompensation adjusting screwø 2 mm safety socket for reference connectionIsoprobe® II 10:1 450MHz probePush-on hook clip with additional reference lead (600 V, CAT II)Push-on BNC plug (500 V, CAT II).
Tektronix high voltage probing solutions offer safety and ...
Description:
Tektronix high voltage probing solutions offer safety and accuracy in applications which include: floating measurements; switching power supply design; motor drive design; electronic ballast design; CRT display design; power converter design and service; power device evaluation. Overrange indicatorSafety certifiedSwitchable attenuationSwitchable bandwidth limitCable length 1.5m (THDP & TMDP), 1.8m (P52xxA).
342-4594 - SCC120 accessory kit for scopemeter 123260-0034 ...
Description:
342-4594 - SCC120 accessory kit for scopemeter 123260-0034 - C125 Soft carrying case260-0028 - Hard carrying case for scopemeter 123548-8938 - BP120 batt pck, ScopeMeter 123preRev2.0480-4137 - PM8907 replacement battery charger (UK Plug)744-2518 - Instrument connector 4mm shielded banana, cable length 1.2m.
LeCroy PPE series probes are suitable for a ...
Description:
LeCroy PPE series probes are suitable for a wide range of applications where high-voltage measurements must be made safely and accurately. New technology, using hybrid circuitry, minimizes ringing and overshoot to provide a precise response. The fixed-attenuation standard probes automatically re-scale any LeCroy 9300C or LC series oscilloscope for the ...