An oscilloscope is considered to be the most used instrument for electrical engineers who need to measure electrical characteristics of electronic devices but you also need at least one probe.
Things to consider when choosing probes
• Ensure the probe's input connector matches the connector on your scope
• Choose a probe whose input resistance and capacitance match the input resistance and capacitance of your scope - matching is critical for guaranteeing proper signal transfer and signal accuracy
The best approach, for matching a probe with a scope, is to first choose a probe whose capacitance is within the range of your scope and then fine-tune the probe's capacitance by adjusting its compensation network using the probe's trimmer capacitor.
The 1X probes are suitable for many low frequency applications. They typically offer the same input impedance of the oscilloscope which is normally 1 M Ohm. The most common type of probe with a built in attenuator gives an attenuation of ten, and it is known as a 10X oscilloscope probe
Types of probes
Passive probes are the most commonly used probes for taking measurements. They are easy to use, relatively inexpensive, and fairly rugged. Available in the following configurations:
• 1´: no attenuation
• 10´: factor-of-10 attenuation
• 100´: factor-of-100 attenuation
• 1000´: factor-of-1000 attenuation
Attenuation probes serve to multiply the voltage measurement range of the oscilloscope by using an internal resistor that, when used in conjunction with the input resistance of the scope, creates a voltage divider. Useful for the following reasons:
• It allows for the measurement of a signal that might exceed the limits of the oscilloscope.
• The attenuation circuitry results in higher resistance and lower capacitance, which is important for high-frequency measurements.
Active probes contain active components, such as FETs or amplifiers. Commonly used for taking high-speed measurements (>500 MHz) or on high-impedance circuits. One limitation is their limited voltage range.
Differential probes are popular for measuring high-frequency signals or signals of very low amplitude.
A current probe measures the electrical current flowing through a conductor.
Tips
• Always use an appropriate probe tip and/or probe tip adapter whenever possible
• Keep ground leads short

...
Read more Read less

Filters

Viewing 1 - 20 of 215 products
Results per page
Description Price Probe Type Attenuation Bandwidth Maximum Common Mode Input Voltage Connector Type Model Number p Number of Probes Safety Category Level Safety Category Voltage Calibrated Series Safety Category Rise Time
RS Stock No. 123-6478
BrandRS PRO
£387.41
Each
Units
Differential, High Voltage 1:10, 1:100 50MHz 1.5kV - - 1 - - - - - -
RS Stock No. 123-6479
BrandRS PRO
£721.89
Each
Units
Differential, High Voltage 1:50, 1:500 70MHz 1.5kV - - 1 - - - - - -
RS Stock No. 146-6623
BrandRS PRO
£48.07
Each
Units
Passive 1:100 300MHz 700V BNC - 1 CAT I 2500V - - CAT I 2500 V 1.2ns
RS Stock No. 146-6617
BrandRS PRO
£45.20
Each
Units
Passive 1:1, 1:10 20 MHz, 250 MHz 600V BNC - 2 CAT I 600V - - CAT I 600 V 1.4 ns, 18 ns
RS Stock No. 146-6624
BrandRS PRO
£2.49
Each
Units
Passive - - - - - - - - - - - -
RS Stock No. 146-6615
BrandRS PRO
£32.54
Each
Units
Passive 1:1, 1:10 15 MHz, 150 MHz 600V BNC - 2 CAT I 600V - - CAT I 600 V 2.3 ns, 24 ns
RS Stock No. 179-9566
BrandRS PRO
£1,324.21
Each
Units
Differential 1:100, 1:1000 70MHz 5kV BNC - 1 CAT I - - - CAT I 5000 Vrms 5ns
RS Stock No. 146-6613
BrandRS PRO
£22.44
Each
Units
Passive 1:10 150MHz 20V BNC - 1 CAT I 600V - - CAT I 600 V 2.3ns
New
RS Stock No. 179-9564
BrandRS PRO
£35.38
Each
Units
Passive 10:1 200 - BNC - 1 CAT II 400 Vrms - RS-TP CAT II 400Vrms <1.75ns
New
RS Stock No. 179-9561
BrandRS PRO
£26.54
Each
Units
Passive 10:1 100 - BNC - 1 CAT II 400 Vrms - RS-TP CAT II 400Vrms <3.5ns
New
RS Stock No. 179-9557
BrandRS PRO
£124.62
Each
Units
Passive 10:1 500MHz - BNC - 1 CAT II 400 Vrms - RS-TP CAT II 400Vrms <1ns
RS Stock No. 146-6618
BrandRS PRO
£65.08
Each
Units
Passive 1:10 300MHz 1.5kV BNC - 1 CAT I, CAT II 300 V, 600 V - - CAT I 600 V, CAT II 300 V 1.2ns
RS Stock No. 146-6622
BrandRS PRO
£43.78
Each
Units
Passive 1:100 300MHz 1.5V BNC - 1 CAT I 1500V - - CAT I 1500 V 1.2ns
RS Stock No. 146-6626
BrandRS PRO
£6.82
Each
Units
PC Oscilloscope Probe Kit - - - BNC - - - - - - - -
RS Stock No. 146-6616
BrandRS PRO
£29.56
Each
Units
Passive 1:1, 1:10 20 MHz, 250 MHz 600V BNC - 1 CAT I 600V - - CAT I 600 V 1.4 ns, 18 ns
RS Stock No. 146-6614
BrandRS PRO
£20.55
Each
Units
Passive 1:1, 1:10 15 MHz, 150 MHz 600V BNC - 1 CAT I 600V - RS-LF Series CAT I 600 V 2.3 ns, 24 ns
RS Stock No. 179-9565
BrandRS PRO
£443.63
Each
Units
Active 1:10, 1:100 25 700V BNC - - CAT III - - - - 14ns
RS Stock No. 146-6612
BrandRS PRO
£21.65
Each
Units
Passive 1:10 25MHz 400V BNC - 1 CAT I 400V - - CAT I 400 V 14ns
New
RS Stock No. 179-9563
BrandRS PRO
£38.38
Each
Units
Passive 10:1 200 - BNC - 1 CAT II 400 Vrms - RS-TP CAT II 400Vrms <1.75ns
New
RS Stock No. 179-9560
BrandRS PRO
£27.15
Each
Units
Passive 10:1 100MHz - BNC - 1 CAT II 400 Vrms - RS-TP CAT II 400Vrms <3.5ns
Related Products
MDO3000 oscilloscopes are designed to meet users' needs ...
Description:
MDO3000 oscilloscopes are designed to meet users' needs and aspirations now and into the future. Each model is multi-functional with integrated basic spectrum analyzer, Wave Inspector Navigation, MSO, serial and parallel bus triggering and analysis, and digital voltmeter. Optional instrument upgrade and application modules can be bought at the time ...
RS Pro Passive Oscilloscope Probe RS-LF Series. Ergonomically ...
Description:
RS Pro Passive Oscilloscope Probe RS-LF Series. Ergonomically designed probe suitable for use with all major brands of oscilloscopes as well as our range. RS Pro passive oscilloscope probes don't require a power supply or batteries so are lightweight and easily portable. • LF Oscilloscope Probe• Protective caps• Spring hook ...
For high-speed switch mode power supply design; CAN/LIN ...
Description:
For high-speed switch mode power supply design; CAN/LIN bus design; high-speed digital design; digital design and characterization; manufacturing engineering test; research and development. ±42 V (DC + pk AC) differential input voltage 18 dB CMRR (at 250 MHz 50X attenuation) Selectable bandwidth limiting filters DC rejectConnects to some Tektronix oscilloscopes ...
Solves three longstanding problems by providing: lower DUT ...
Description:
Solves three longstanding problems by providing: lower DUT loading (≤1 pF/1 MΩ probe loading); direct and easy access to SMDs; accesses DUT signals and scope bandwidth for TDS600/700/3000/5000/6000/7000*1 and CSA7000 scopes up to 1 GHz bandwidths. Provides the electrical and mechanical performance required for today's digital systems designs. No additional ...