Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | Dold | |
Monitoring Application | Insulation | |
Electrical Phase | 1, 3 | |
Voltage Sensing Range | 0.8 → 1.1 V | |
Contact Configuration | SPDT | |
Mounting Type | DIN Rail | |
Time Delay | <4.2s | |
Series | AI 897 | |
Width | 45mm | |
Maximum Operating Temperature | +60°C | |
Dimensions | 115 x 45 x 77mm | |
Operating Temperature Range | +60°C | |
Length | 115mm | |
Height | 77mm | |
Minimum Operating Temperature | -20°C | |
Select all | ||
---|---|---|
Brand Dold | ||
Monitoring Application Insulation | ||
Electrical Phase 1, 3 | ||
Voltage Sensing Range 0.8 → 1.1 V | ||
Contact Configuration SPDT | ||
Mounting Type DIN Rail | ||
Time Delay <4.2s | ||
Series AI 897 | ||
Width 45mm | ||
Maximum Operating Temperature +60°C | ||
Dimensions 115 x 45 x 77mm | ||
Operating Temperature Range +60°C | ||
Length 115mm | ||
Height 77mm | ||
Minimum Operating Temperature -20°C | ||
- COO (Country of Origin):
- DE
Insulation monitor for pure 3 phase and alternating current systems, AI897
Adjustable response value 10 → 80 kΩ
No separate auxiliary voltage connection required
1 changeover
Overall width 45 mm
No separate auxiliary voltage connection required
1 changeover
Overall width 45 mm
The AI897 insulation monitor displays the insulation resistance of unearthed 3 phase and alternating current systems to earth.
The device works according to the quiescent current principle, that is, the output relay responds when mains voltage is applied to terminals A1 → A2. The output relay breaks when the response setpoint is undercut.
A bridge between terminals LT1 and LT2 allows the AI897 to be programmed for memory storage behaviour; remove the bridge to programme hysteresis behaviour. The bridge can be replaced with a delete key with an NC contact. There is a PT test button on the front of the device to test for functional efficiency. An external test button (in accordance with VDE 0413) is also possible.
The device works according to the quiescent current principle, that is, the output relay responds when mains voltage is applied to terminals A1 → A2. The output relay breaks when the response setpoint is undercut.
A bridge between terminals LT1 and LT2 allows the AI897 to be programmed for memory storage behaviour; remove the bridge to programme hysteresis behaviour. The bridge can be replaced with a delete key with an NC contact. There is a PT test button on the front of the device to test for functional efficiency. An external test button (in accordance with VDE 0413) is also possible.

Related links
- Dold Insulation Monitoring Relay 0.8 → 1.1 V, DIN Rail
- Dold Insulation Monitoring Relay 3 Phase 0 → 500V ac, DIN Rail
- Dold Insulation Monitoring Relay 3 Phase 0 → 500V ac, DIN Rail
- ABB Insulation Monitoring Relay 3 Phase 0 → 400 V ac DIN Rail
- Dold Insulation Monitor DIN Rail
- Dold Insulation Monitor 400 → 1000V ac/dc, DIN Rail
- Dold Standstill Monitoring Relay 3 Phase Maximum of 4 V, DIN Rail
- ABB Insulation Monitoring Relay 3 Phase 0 → 690V ac, DIN Rail