Dold Thermistor Motor Protection Monitoring Relay, SPDT, DIN Rail
- RS Stock No.:
- 240-8995
- Mfr. Part No.:
- MK9052.11 AC50/60Hz 230V
- Brand:
- Dold
Subtotal (1 unit)*
£116.42
(exc. VAT)
£139.70
(inc. VAT)
FREE delivery for orders over £50.00
In Stock
- 3 unit(s) ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
---|---|
1 + | £116.42 |
*price indicative
- RS Stock No.:
- 240-8995
- Mfr. Part No.:
- MK9052.11 AC50/60Hz 230V
- Brand:
- Dold
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | Dold | |
Monitoring Application | Thermistor motor temperature protection | |
Contact Configuration | SPDT | |
Mounting Type | DIN Rail | |
Time Delay | <20ms | |
Series | MK 9052 | |
Operating Temperature Range | +60°C | |
Minimum Operating Temperature | -20°C | |
Maximum Operating Temperature | +60°C | |
Width | 22.5mm | |
Length | 99mm | |
Height | 82mm | |
Dimensions | 99 x 22.5 x 82mm | |
Select all | ||
---|---|---|
Brand Dold | ||
Monitoring Application Thermistor motor temperature protection | ||
Contact Configuration SPDT | ||
Mounting Type DIN Rail | ||
Time Delay <20ms | ||
Series MK 9052 | ||
Operating Temperature Range +60°C | ||
Minimum Operating Temperature -20°C | ||
Maximum Operating Temperature +60°C | ||
Width 22.5mm | ||
Length 99mm | ||
Height 82mm | ||
Dimensions 99 x 22.5 x 82mm | ||
- COO (Country of Origin):
- DE
MK9052 - Thermistor motor protection relay
1 input for thermistors or bi-metallic contacts
Wire breakage detection in the sensor circuit
LED for switching status
Rest current principle
1 changeover
22.5 mm overall width
Wire breakage detection in the sensor circuit
LED for switching status
Rest current principle
1 changeover
22.5 mm overall width
The MK9052 motor protection relay is used to prevent thermal overloads in motors (for example as caused by high switching frequencies, heavy start-up loads, single phase operation, interrupted cooling, high ambient temperature).
Special thermistors (PTC resistors) developed specifically for motor protection are used as temperature sensors. Up to 6 sensors can be switched in sequence; when a fixed resistance level is reached, they cause the output relay of the MK9052 to de-energise.
Special thermistors (PTC resistors) developed specifically for motor protection are used as temperature sensors. Up to 6 sensors can be switched in sequence; when a fixed resistance level is reached, they cause the output relay of the MK9052 to de-energise.

Related links
- Dold Thermistor Motor Protection Monitoring Relay DIN Rail
- Dold Frequency Monitoring Relay DIN Rail
- Dold Current Monitoring Relay DIN Rail
- Dold Temperature Monitoring Relay DIN Rail
- Dold Standstill Monitoring Relay 3 Phase DIN Rail
- Siemens Thermistor Motor Protection Monitoring Relay DIN Rail
- Carlo Gavazzi Thermistor Motor Protection Monitoring Relay DIN Rail
- Dold Safemaster BD 5987 Safety Relay 230V ac, Dual-Channel 2 Safety Contacts