Dold Insulation Monitoring Relay, 1, 3 Phase, SPDT, 0 → 500V ac, DIN Rail
- RS Stock No.:
- 181-2774
- Mfr. Part No.:
- MK5880N.38/200
- Brand:
- Dold
Subtotal (1 unit)*
£236.22
(exc. VAT)
£283.46
(inc. VAT)
FREE delivery for orders over £50.00
In Stock
- 1 unit(s) ready to ship from another location
- Plus 999,999,998 unit(s) shipping from 20 November 2025
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | £236.22 |
*price indicative
- RS Stock No.:
- 181-2774
- Mfr. Part No.:
- MK5880N.38/200
- Brand:
- Dold
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Dold | |
| Monitoring Application | Insulation | |
| Electrical Phase | 1, 3 | |
| Contact Configuration | SPDT | |
| Voltage Sensing Range | 0 → 500V ac | |
| Mounting Type | DIN Rail | |
| Time Delay | 1.3s | |
| Frequency Sensing Range | 10 → 1000Hz | |
| Series | MK5880N | |
| Minimum Frequency Sensed | 10Hz | |
| Operating Temperature Range | +60°C | |
| Maximum Frequency Sensed | 1000Hz | |
| Maximum Operating Temperature | +60°C | |
| Width | 22.5mm | |
| Dimensions | 97 x 22.5 x 90mm | |
| Minimum Voltage Sensed | 0V ac | |
| Terminal Type | Screw | |
| Maximum Voltage Sensed | 500V ac | |
| Height | 90mm | |
| Length | 97mm | |
| Minimum Operating Temperature | -20°C | |
Select all | ||
|---|---|---|
Brand Dold | ||
Monitoring Application Insulation | ||
Electrical Phase 1, 3 | ||
Contact Configuration SPDT | ||
Voltage Sensing Range 0 → 500V ac | ||
Mounting Type DIN Rail | ||
Time Delay 1.3s | ||
Frequency Sensing Range 10 → 1000Hz | ||
Series MK5880N | ||
Minimum Frequency Sensed 10Hz | ||
Operating Temperature Range +60°C | ||
Maximum Frequency Sensed 1000Hz | ||
Maximum Operating Temperature +60°C | ||
Width 22.5mm | ||
Dimensions 97 x 22.5 x 90mm | ||
Minimum Voltage Sensed 0V ac | ||
Terminal Type Screw | ||
Maximum Voltage Sensed 500V ac | ||
Height 90mm | ||
Length 97mm | ||
Minimum Operating Temperature -20°C | ||
- COO (Country of Origin):
- DE
Features
• According to IEC/EN 61 557-8
• For single and 3-phase AC-systems up to 0 ... 500 V and 10 ... 1000 Hz
• Monitors also disconnected voltage systems
• Adjustable tripping value RALof 5 ... 100 kΩ
• De-energized on trip
• Auxiliary voltage, measuring circuit and output contacts are galvanically separated
• Manual and auto reset
• With test and reset button
• Connections for external test and reset buttons possible
• LED indicators for operation and alarm
• 2 changeover contacts
• MK 5880N/200 with additional prewarning
- adjustable prewarning value 10 kΩ ... 5 MΩ
- 1 output relay for alarm and 1 for pre-warning
• MH 5880/500: similar to MK 5880N but with galvanic separated analogue output and 11 step LED chain for the actual insulation value
• Wire connection: also 2 x 1.5 mm2 stranded ferruled, or
2 x 2.5 mm2 solid DIN 46 228-1/-2/-3/-4
• As option with pluggable terminal blocks for easy exchange of devices
- with screw terminals
- or with cage clamp terminals
• MK 5880N: 22.5 mm width
MH 5880: 45 mm width
• According to IEC/EN 61 557-8
• For single and 3-phase AC-systems up to 0 ... 500 V and 10 ... 1000 Hz
• Monitors also disconnected voltage systems
• Adjustable tripping value RALof 5 ... 100 kΩ
• De-energized on trip
• Auxiliary voltage, measuring circuit and output contacts are galvanically separated
• Manual and auto reset
• With test and reset button
• Connections for external test and reset buttons possible
• LED indicators for operation and alarm
• 2 changeover contacts
• MK 5880N/200 with additional prewarning
- adjustable prewarning value 10 kΩ ... 5 MΩ
- 1 output relay for alarm and 1 for pre-warning
• MH 5880/500: similar to MK 5880N but with galvanic separated analogue output and 11 step LED chain for the actual insulation value
• Wire connection: also 2 x 1.5 mm2 stranded ferruled, or
2 x 2.5 mm2 solid DIN 46 228-1/-2/-3/-4
• As option with pluggable terminal blocks for easy exchange of devices
- with screw terminals
- or with cage clamp terminals
• MK 5880N: 22.5 mm width
MH 5880: 45 mm width
Related links
- Dold Insulation Monitoring Relay 3 Phase 0 → 500V ac, DIN Rail
- Dold Insulation Monitoring Relay 3 Phase 0 → 500V ac, DIN Rail
- Dold Insulation Monitoring Relay 3 Phase 0.8 → 1.1 V, DIN Rail
- ABB Insulation Monitoring Relay 3 Phase 0 → 400V ac, DIN Rail
- ABB Insulation Monitoring Relay 3 Phase 0 → 250V ac, DIN Rail
- Dold Insulation Monitoring Relay 0.8 → 1.1 V, DIN Rail
- Dold Voltage Monitoring Relay 3 Phase 0 → 500V ac, DIN Rail
- ABB Insulation Monitoring Relay 3 Phase 0 → 250 V ac DIN Rail