Schneider Electric Acti9 iC60L Miniature Circuit Breaker, 2-Pole, 20 A, Type C, 100 V, 12 V, 130 V, 220 V, 240 V, 380 V,
- RS Stock No.:
- 734-9318
- Mfr. Part No.:
- A9F94220
- Brand:
- Schneider Electric
Image representative of range
Subtotal (1 unit)*
£197.68
(exc. VAT)
£237.22
(inc. VAT)
FREE delivery for orders over £50.00
- 9 unit(s) ready to ship from another location
Units | Per unit |
|---|---|
| 1 + | £197.68 |
*price indicative
- RS Stock No.:
- 734-9318
- Mfr. Part No.:
- A9F94220
- Brand:
- Schneider Electric
Select all | Attribute | Value |
|---|---|---|
| Brand | Schneider Electric | |
| Number of Poles | 2 | |
| Product Type | Miniature Circuit Breaker | |
| Current Rating | 20 A | |
| Tripping Characteristics | Type C | |
| Rated AC Voltage | 100 V, 12 V, 130 V, 220 V, 240 V, 380 V, 400 V, 415 V, 440 V, 60 V | |
| Rated DC Voltage | 144 V dc | |
| Breaking Capacity | 15kA | |
| Mount Type | DIN Rail | |
| Range | Acti9 | |
| Series | iC60L | |
| Terminal Type | Screw | |
| IP Rating | IP20 | |
| Width | 36 mm | |
| Height | 85mm | |
| Depth | 78.5mm | |
| Standards/Approvals | RoHS, REACH, EN/IEC 60947-2, EN/IEC 60898-1 | |
| Reset Actuator Type | Toggle Switch | |
| Break Time | Instantaneous | |
| Tripping Mechanism | Thermal Magnetic | |
| Select all | ||
|---|---|---|
Brand Schneider Electric | ||
Number of Poles 2 | ||
Product Type Miniature Circuit Breaker | ||
Current Rating 20 A | ||
Tripping Characteristics Type C | ||
Rated AC Voltage 100 V, 12 V, 130 V, 220 V, 240 V, 380 V, 400 V, 415 V, 440 V, 60 V | ||
Rated DC Voltage 144 V dc | ||
Breaking Capacity 15kA | ||
Mount Type DIN Rail | ||
Range Acti9 | ||
Series iC60L | ||
Terminal Type Screw | ||
IP Rating IP20 | ||
Width 36 mm | ||
Height 85mm | ||
Depth 78.5mm | ||
Standards/Approvals RoHS, REACH, EN/IEC 60947-2, EN/IEC 60898-1 | ||
Reset Actuator Type Toggle Switch | ||
Break Time Instantaneous | ||
Tripping Mechanism Thermal Magnetic | ||
- COO (Country of Origin):
- FR
A9F94220 Schneider Electric
Schneider Electric Acti9 iC60L MCBs 1 Pole
Benefits and Features
Standards
Q: What is the differences in the Tripping Curves B, C, and D?
Related links
- Schneider Electric Acti9 iC60L Miniature Circuit Breaker 10 A 12 V DC, 15 kA Breaking Capacity
- Schneider Electric Acti9 iC60L Miniature Circuit Breaker 16 A 12 V DC, 15 kA Breaking Capacity
- Schneider Electric Acti9 IC60N Miniature Circuit Breaker 1 A 144 V DC, 10 kA Breaking Capacity
- Schneider Electric Acti9 iC60L Miniature Circuit Breaker 20 A 250 V DC, 15 kA Breaking Capacity
- Schneider Electric Acti9 iC60L Miniature Circuit Breaker 40 A 250 V DC, 15 kA Breaking Capacity
- Schneider Electric Acti9 iC60L Miniature Circuit Breaker 25 A 250 V DC, 15 kA Breaking Capacity
- Schneider Electric Acti9 iC60L Miniature Circuit Breaker 16 A 250 V DC, 15 kA Breaking Capacity
- Schneider Electric Acti9 iC60L Miniature Circuit Breaker 32 A 250 V DC, 15 kA Breaking Capacity