Schneider Electric Acti 9 iC60L MCB, 4P, 25A Curve C, 100 → 130V AC, 12 → 250V DC, 10 kA Breaking Capacity
- RS Stock No.:
- 734-9315
- Mfr. Part No.:
- A9F94425
- Brand:
- Schneider Electric
Image representative of range
Subtotal (1 unit)*
£425.90
(exc. VAT)
£511.08
(inc. VAT)
FREE delivery for orders over £50.00
- 8 unit(s) ready to ship from another location
Units | Per unit |
|---|---|
| 1 + | £425.90 |
*price indicative
Better World
Our Better World range features products that make it easy for you to make a greener product choice you can trust. Click here to find out more.
- RS Stock No.:
- 734-9315
- Mfr. Part No.:
- A9F94425
- Brand:
- Schneider Electric
Select all | Attribute | Value |
|---|---|---|
| Brand | Schneider Electric | |
| Number of Poles | 4 | |
| Current Rating | 25A | |
| Tripping Characteristics | Type C | |
| Rated AC Voltage | 100 → 130 V, 12 → 60 V, 220 → 240 V, 380 → 415 V, 400 V, 440V | |
| Rated DC Voltage | 12 → 250V | |
| Breaking Capacity at Maximum Voltage Rating | 10 kA | |
| Range | Acti 9 | |
| Series | iC60L | |
| Circuit Breaker Type | MCB | |
| Width | 72mm | |
| Mounting Style | DIN Rail Mount | |
| Better World Verification | Green Premium | |
| Better World Product | Yes | |
Select all | ||
|---|---|---|
Brand Schneider Electric | ||
Number of Poles 4 | ||
Current Rating 25A | ||
Tripping Characteristics Type C | ||
Rated AC Voltage 100 → 130 V, 12 → 60 V, 220 → 240 V, 380 → 415 V, 400 V, 440V | ||
Rated DC Voltage 12 → 250V | ||
Breaking Capacity at Maximum Voltage Rating 10 kA | ||
Range Acti 9 | ||
Series iC60L | ||
Circuit Breaker Type MCB | ||
Width 72mm | ||
Mounting Style DIN Rail Mount | ||
Better World Verification Green Premium | ||
Better World Product Yes | ||
- COO (Country of Origin):
- FR
Schneider Electric Acti9 iC60L MCBs 1 Pole
VisiTrip red window on the front face indicates fault tripping allowing fast diagnosis, resolution, and reclosing loads for easier building management and reduced downtime
Benefits and Features
Class-2 insulation: ensures continuous protection for both operators and unqualified persons
Insulated terminals (IP20)
Highly durable with robust connections that provide twice the standard tightening torque
Provide greater continuity of service thanks to VisiTrip.
Double clip for dismounting with comb busbar in place
Standards
Installations. In the UK traditionally known as miniature circuit breakers
(MCBs).
IEC 60947-2 Relates to Low Voltage Circuit Breakers for use in industrial and similar
Installations. In the UK traditionally known as moulded case circuit breakers
(MCCBs) and also air circuit breakers (ACBs).
Q: What is the differences in the Tripping Curves B, C, and D?
Applications: protection of generators, persons, very long cables
Curve C: Tripping: 5 to 10 times the rated current
Applications: protection of circuits and general applications
Curve D: Tripping: 10 to 14 times the rated current
Applications: protection of high surge circuits, welders, transformers and motors
A9F94425 Schneider Electric
Related links
- Schneider Electric Acti 9 iC60L MCB 40A Curve C 12 → 250V DC, 10 kA Breaking Capacity
- Schneider Electric Acti 9 iC60L MCB 20A Curve C 12 → 144V DC, 10 kA Breaking Capacity
- Schneider Electric Acti 9 iC60L MCB 10A Curve C 12 → 144V DC, 10 kA Breaking Capacity
- Schneider Electric Acti 9 IC60L MCB 25A Curve B 250V DC 15 kA Breaking Capacity
- Schneider Electric Acti 9 iC60L MCB 32A Curve C 12 → 250V DC, 10 kA Breaking Capacity
- Schneider Electric Acti 9 iC60L MCB 20A Curve C 12 → 250V DC, 10 kA Breaking Capacity
- Schneider Electric Acti 9 iC60L MCB 16A Curve C 12 → 250V DC, 10 kA Breaking Capacity
- Schneider Electric Acti 9 iC60L MCB 25A Curve K, 15 kA Breaking Capacity