Allen Bradley 1492 1492-SPM MCB, 3P, 13A Curve B, 277V AC, 10 kA Breaking Capacity
- RS Stock No.:
- 125-1443
- Mfr. Part No.:
- 1492-SPM3B130
- Brand:
- Allen Bradley
Subtotal (1 unit)*
£58.37
(exc. VAT)
£70.04
(inc. VAT)
FREE delivery for orders over £50.00
Temporarily out of stock
- 999,999,999 unit(s) shipping from 22 December 2025
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
---|---|
1 + | £58.37 |
*price indicative
- RS Stock No.:
- 125-1443
- Mfr. Part No.:
- 1492-SPM3B130
- Brand:
- Allen Bradley
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | Allen Bradley | |
Number of Poles | 3 | |
Current Rating | 13A | |
Tripping Characteristics | Type B | |
Rated AC Voltage | 277 V, 480V | |
Breaking Capacity at Maximum Voltage Rating | 10 kA | |
Range | 1492 | |
Series | 1492-SPM | |
Circuit Breaker Type | MCB | |
Width | 75mm | |
Length | 53mm | |
Mounting Style | DIN Rail Mount | |
Depth | 88mm | |
Break Time | Instantaneous | |
Terminal Contact Type | Screw | |
Reset Actuator Type | Toggle Switch | |
Application | General Purpose | |
Tripping Mechanism | Thermal-Magnetic | |
Select all | ||
---|---|---|
Brand Allen Bradley | ||
Number of Poles 3 | ||
Current Rating 13A | ||
Tripping Characteristics Type B | ||
Rated AC Voltage 277 V, 480V | ||
Breaking Capacity at Maximum Voltage Rating 10 kA | ||
Range 1492 | ||
Series 1492-SPM | ||
Circuit Breaker Type MCB | ||
Width 75mm | ||
Length 53mm | ||
Mounting Style DIN Rail Mount | ||
Depth 88mm | ||
Break Time Instantaneous | ||
Terminal Contact Type Screw | ||
Reset Actuator Type Toggle Switch | ||
Application General Purpose | ||
Tripping Mechanism Thermal-Magnetic | ||
- COO (Country of Origin):
- DE
Allen Bradley 1492 SP Series Miniature Circuit Breakers – Type B
The 1492-SPM Type B general purpose Miniature Circuit Breakers by Allen Bradley offer excellent protection for electrical circuits. With this series 1, 2, and 3 Pole units are available so that you can find the perfect MCB to suit your application.
The 1492-SPM series of MCBs are current limiting and have an instantaneous break time. These models have Type B Tripping characteristics. They are IP20 finger-safe and they also have dual terminals for wiring and bus bar flexibility. Installation is simple as these MCBs can be DIN rail mounted, and up to six accessories can be fixed on the same circuit breaker to provide a complete electrical safety system. The 1492-SPM series of circuit breakers reduces downtime from nuisance tripping due to their enhanced shock and vibration resistance.
A Type B miniature circuit breaker will trip instantly at a rate of three to five times its rated current. These MCBs are often used for small inductive loads where switching surges are very low. They are frequently used in residential or light commercial applications.
Features and Benefits:
• Easy and fast installation via DIN rail mounting
• Instantaneous break time
• Available in 1, 2 or 3 pole versions
• Thermal-magnetic tripping mechanism
• Clear visibility of contact state due to indicator window: red for closed, green for open
• Environmentally friendly - RohS compliant and fully recyclable
• Screw Terminals
• Can function in extreme ambient conditions due to 40 ˚C (104 °F) calibration temperature
• Instantaneous break time
• Available in 1, 2 or 3 pole versions
• Thermal-magnetic tripping mechanism
• Clear visibility of contact state due to indicator window: red for closed, green for open
• Environmentally friendly - RohS compliant and fully recyclable
• Screw Terminals
• Can function in extreme ambient conditions due to 40 ˚C (104 °F) calibration temperature
Certifications:
UL Recognised
CSA Certified
CE Marked
CCC Certified
VDE Certified
RoHS Compliant
CSA Certified
CE Marked
CCC Certified
VDE Certified
RoHS Compliant
Standards:
UL 1077
CSA C22.2 No. 235
EN 60947-2
GB 14048.2
CSA C22.2 No. 235
EN 60947-2
GB 14048.2
Allen Bradley MCB, 4kV Rated Impulse Withstand Voltage, 13A Current Rating - 1492-SPM3B130
Safeguard your appliances from electrical faults with this MCB from Rockwell Automation's Allen Bradley range. It features a thermal-magnetic tripping mechanism, meaning protects your electrical setup from short circuits and current overloads. Thanks to an integrated toggle switch, it's easy to reset the device when the fault is cleared. As a type B device, it trips at 3 to 5 times its rated current, so it's useful for small inductive loads with low switching surges. MCBs like this are used in light commercial applications, such as home and office wiring.
• Shock-resistant design to prevent nuisance tripping in vibrating systems
• Broad operating temperature range of -25°C to +55°C for use in demanding conditions
• IP40 rating means that it's protected from objects larger than 1mm in size
• Current rating of 13A for use in high-current-consuming applications
• Broad operating temperature range of -25°C to +55°C for use in demanding conditions
• IP40 rating means that it's protected from objects larger than 1mm in size
• Current rating of 13A for use in high-current-consuming applications
Standards and Certifications
• CSA C22.2 No. 235
• UL 1077
• EN 60947-2
• GB 14048.2
• UL Recognised
• CE Marked
• CSA, CCC and VDE Certified
• UL 1077
• EN 60947-2
• GB 14048.2
• UL Recognised
• CE Marked
• CSA, CCC and VDE Certified
How do I terminate cables to this MCB?
This MCB has a dual terminal construction, which means that you can connect both cables and busbars using a simple No.2 Pozidriv screwdriver.
Allen Bradley MCBs
Related links
- Allen Bradley 1492-SP 1492-SPM MCB 13A Curve B
- Allen Bradley 1492 1492-SPM MCB 4A Curve B 10 kA Breaking Capacity
- Allen Bradley 1492 1492-SPM MCB 20A Curve B 10 kA Breaking Capacity
- Allen Bradley 1492 1492-SPM MCB 63A Curve B 10 kA Breaking Capacity
- Allen Bradley 1492 1492-SPM MCB 1A Curve B 10 kA Breaking Capacity
- Allen Bradley 1492 1492-SPM MCB 6A Curve B 10 kA Breaking Capacity
- Allen Bradley 1492 1492-SPM MCB 2A Curve B 10 kA Breaking Capacity
- Allen Bradley 1492 1492-SPM MCB 40A Curve B 10 kA Breaking Capacity