Honeywell 14CE Series Plunger Limit Switch, SPDT, IP68, IP67, IP66, IP65, Die Cast Zinc Housing, 250V ac, 5A
- RS Stock No.:
- 246-3065
- Distrelec Article No.:
- 301-38-480
- Mfr. Part No.:
- 14CE3-3
- Brand:
- Honeywell
Subtotal (1 unit)*
£201.57
(exc. VAT)
£241.88
(inc. VAT)
FREE delivery for orders over £60.00
In Stock
- 16 unit(s) ready to ship
- Plus 1 unit(s) ready to ship from another location
- Plus 102 unit(s) shipping from 28 April 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | £201.57 |
*price indicative
- RS Stock No.:
- 246-3065
- Distrelec Article No.:
- 301-38-480
- Mfr. Part No.:
- 14CE3-3
- Brand:
- Honeywell
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Honeywell | |
| Actuator Type | Plunger | |
| Product Type | Limit Switch | |
| Contact Configuration | SPDT | |
| IP Rating | IP68, IP67, IP66, IP65 | |
| Housing Material | Die Cast Zinc | |
| Contact Type | Snap Action | |
| Terminal Type | Cable | |
| Switching Current | 5A | |
| Series | 14CE | |
| Switching AC Voltage | 250V ac | |
| Switching DC Voltage | 30V dc | |
| Minimum Operating Temperature | 0°C | |
| Maximum Operating Temperature | 70°C | |
| Standards/Approvals | CE/EN/IEC | |
| Length | 49mm | |
| Depth | 16mm | |
| Width | 40mm | |
| Hazardous Area Certification | NO | |
| Mounting Orientation | Top | |
| Operating Force | 11.8N | |
| Mechanical Life | 10000000Cycles | |
| Select all | ||
|---|---|---|
Brand Honeywell | ||
Actuator Type Plunger | ||
Product Type Limit Switch | ||
Contact Configuration SPDT | ||
IP Rating IP68, IP67, IP66, IP65 | ||
Housing Material Die Cast Zinc | ||
Contact Type Snap Action | ||
Terminal Type Cable | ||
Switching Current 5A | ||
Series 14CE | ||
Switching AC Voltage 250V ac | ||
Switching DC Voltage 30V dc | ||
Minimum Operating Temperature 0°C | ||
Maximum Operating Temperature 70°C | ||
Standards/Approvals CE/EN/IEC | ||
Length 49mm | ||
Depth 16mm | ||
Width 40mm | ||
Hazardous Area Certification NO | ||
Mounting Orientation Top | ||
Operating Force 11.8N | ||
Mechanical Life 10000000Cycles | ||
- COO (Country of Origin):
- GB

Honeywell 14CE Series Limit Switch, 11.8N Operating Force, IP68 - 14CE3-3
This limit switch is a compact, actuator-driven device designed to detect position changes and provide an electrical switching response in industrial control systems. Fitted with a plunger actuator and intended for TOP mounting, it is suitable for environments where accurate mechanical actuation triggers an SPDT changeover contact. The unit is intended for integration where clear on/off signalling at defined travel end points is required.
Features and Benefits:
• Die-cast zinc housing provides robust enclosure and mechanical protection
• SPDT snap-action contact delivers Rapid changeover at setpoints
• Switching capability of 250V AC and 5A supports AC control circuits
• Switching capability of 30V DC and 5A supports DC control circuits
• Operating force of 11.8N ensures consistent actuation threshold
• Mechanical life rated to 10,000,000 cycles enables long service intervals
• SPDT snap-action contact delivers Rapid changeover at setpoints
• Switching capability of 250V AC and 5A supports AC control circuits
• Switching capability of 30V DC and 5A supports DC control circuits
• Operating force of 11.8N ensures consistent actuation threshold
• Mechanical life rated to 10,000,000 cycles enables long service intervals
Applications
• Suitable for position detection on conveyor end-stops and Gates
• Ideal for use in machinery limit detection in manufacturing lines
• Used for control interlocks on automated handling equipment
• Can be used for end-of-travel signalling in actuator systems
• Suitable for integration into valve position monitoring assemblies
• Ideal for use in machinery limit detection in manufacturing lines
• Used for control interlocks on automated handling equipment
• Can be used for end-of-travel signalling in actuator systems
• Suitable for integration into valve position monitoring assemblies
What Terminal arrangement does it use for wiring?
It is supplied with a cable-style Terminal for direct cable connection to control wiring.
How does ambient temperature affect its operation?
The unit is specified for operation between 0 °C and 70 °C so performance should be validated within that range.
What mounting orientation is required for correct actuation?
The design is intended for TOP mounting to ensure the plunger actuator functions as specified.
Which international standards has it been evaluated against?
It conforms to CE/EN/IEC standards relevant to switch safety and performance.
Is it certified for use in hazardous locations?
It does not carry hazardous area certification and is therefore for non-hazardous environments.
Approvals
UL, CSA.
Warning
14CE limit switches are not emergency stop devices or safety devices. They must not be used in devices, applications and environments where injury can incur as a result of product failure.
Standards
IP Rating:
All models within the 14CE series meet IP65, IP66, IP67, IP68. This ensures that they are completely dust tight, offer protection against jets of water and can be immersed in water up to 3 m.
NEMA Rating:
Every 14CE limit switch also meets NEMA, 2, 3, 3R, 4, 6, 6P and 13 requirements.
Type 2: Allows for indoor use and provides a degree of protection against access to hazardous parts. The enclosures provide a degree of protection against foreign objects (such as falling dirt) and the ingress of water (light dripping or splashing).
Type 3: Allows for indoor or outdoor use and provides a degree of protection against access to hazardous parts. The enclosures provide some protection from foreign objects (such as windblown dust) and the ingress of water (such as rain or snow). Enclosures that meet NEMA 3 offer protection against ice forming externally.
Type 3R: Allows for indoor or outdoor use and provides a degree of protection against access to hazardous parts. The enclosures primarily provide ingress protection against water (such as rain, snow or sleet). Enclosures that meet NEMA 3 offer protection against ice forming externally.
Type 4: Allows for indoor or outdoor use and provides a degree of protection against access to hazardous parts. The enclosures provide some protection from foreign objects (such as falling dirt and windblown dust) and the ingress of water (such as rain, snow or sleet alongside splashing water and hose directed water). Enclosures that meet NEMA 3 offer protection against ice forming externally.
Type 6: Allows for indoor or outdoor use and provides a degree of protection against access to hazardous parts. The enclosures provide some protection from foreign objects (such as falling dirt and windblown dust) and the ingress of water (such as rain, snow or sleet alongside splashing water and hose directed water). Enclosures that meet NEMA 4 offer protection against ice forming externally.
Type 6P: Allows for indoor or outdoor use and provides a degree of protection against access to hazardous parts. The enclosures provide some protection from solid objects (such as falling dirt and windblown dust) and the ingress of water (such as hose directed water). Enclosures that meet the NEMA 6P requirement also offer protection against water when being submerged at a limited depth.
Type 13: Enclosures that meet Type 13 are suited to harsh environments. Enclosures can be used indoors and provide protection against access to hazardous parts. They offer protection against solid objects such as falling dirt, windblown dirt, fibres and lint. They provide a level of protection from dripping and splashing water and other liquids such as the splashing, seepage and spraying of oil and non-corrosive coolants.
All models within the 14CE series meet IP65, IP66, IP67, IP68. This ensures that they are completely dust tight, offer protection against jets of water and can be immersed in water up to 3 m.
NEMA Rating:
Every 14CE limit switch also meets NEMA, 2, 3, 3R, 4, 6, 6P and 13 requirements.
Type 2: Allows for indoor use and provides a degree of protection against access to hazardous parts. The enclosures provide a degree of protection against foreign objects (such as falling dirt) and the ingress of water (light dripping or splashing).
Type 3: Allows for indoor or outdoor use and provides a degree of protection against access to hazardous parts. The enclosures provide some protection from foreign objects (such as windblown dust) and the ingress of water (such as rain or snow). Enclosures that meet NEMA 3 offer protection against ice forming externally.
Type 3R: Allows for indoor or outdoor use and provides a degree of protection against access to hazardous parts. The enclosures primarily provide ingress protection against water (such as rain, snow or sleet). Enclosures that meet NEMA 3 offer protection against ice forming externally.
Type 4: Allows for indoor or outdoor use and provides a degree of protection against access to hazardous parts. The enclosures provide some protection from foreign objects (such as falling dirt and windblown dust) and the ingress of water (such as rain, snow or sleet alongside splashing water and hose directed water). Enclosures that meet NEMA 3 offer protection against ice forming externally.
Type 6: Allows for indoor or outdoor use and provides a degree of protection against access to hazardous parts. The enclosures provide some protection from foreign objects (such as falling dirt and windblown dust) and the ingress of water (such as rain, snow or sleet alongside splashing water and hose directed water). Enclosures that meet NEMA 4 offer protection against ice forming externally.
Type 6P: Allows for indoor or outdoor use and provides a degree of protection against access to hazardous parts. The enclosures provide some protection from solid objects (such as falling dirt and windblown dust) and the ingress of water (such as hose directed water). Enclosures that meet the NEMA 6P requirement also offer protection against water when being submerged at a limited depth.
Type 13: Enclosures that meet Type 13 are suited to harsh environments. Enclosures can be used indoors and provide protection against access to hazardous parts. They offer protection against solid objects such as falling dirt, windblown dirt, fibres and lint. They provide a level of protection from dripping and splashing water and other liquids such as the splashing, seepage and spraying of oil and non-corrosive coolants.
Related links
- Honeywell 14CE Series Plunger Limit Switch IP68 IP66 Die Cast Zinc Housing 5 A
- Honeywell 14CE Series Roller Plunger Limit Switch IP66 IP68 Die Cast Zinc Housing 5 A
- Honeywell 14CE Series Roller Plunger Limit Switch IP66 IP67 Die Cast Zinc Housing 5
- Honeywell 14CE Series Plunger Limit Switch IP65 250 V ac, 5 A
- Honeywell 14CE Series Roller Plunger Limit Switch IP66 250 V ac, 5 A
- Honeywell 14CE Series Plunger Limit Switch IP65 IP67 Die Cast Zinc Housing 5 A
- Honeywell 14CE Series Plunger Limit Switch IP65 IP68 240 V ac, 5 A
- Honeywell 14CE Series Plunger Limit Switch IP66 250 V ac, 5 A