Honeywell SZL-VL Series Roller Plunger Limit Switch, 1 NO/1 NC, IP67, Metal Housing, 380V ac, 10A

Subtotal (1 unit)*

£47.77

(exc. VAT)

£57.32

(inc. VAT)

Add to Basket
Select or type quantity
In Stock
  • 10 unit(s) ready to ship
  • Plus 10 unit(s) ready to ship from another location
  • Plus 100 unit(s) shipping from 15 May 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units
Per unit
1 +£47.77

*price indicative

RS Stock No.:
144-8404
Mfr. Part No.:
SZL-VL-S-H-N-M
Brand:
Honeywell
Find similar products by selecting one or more attributes.
Select all

Brand

Honeywell

Product Type

Limit Switch

Actuator Type

Roller Plunger

Contact Configuration

1 NO/1 NC

IP Rating

IP67

Housing Material

Metal

Contact Type

Snap Action

Switching Current

10A

Terminal Type

M12

Series

SZL-VL

Switching AC Voltage

380V ac

Switching DC Voltage

220V dc

Minimum Operating Temperature

-20°C

Maximum Operating Temperature

70°C

Width

98.5mm

Standards/Approvals

cULus, CCC, CE

Length

28.5mm

Depth

25.7mm

Hazardous Area Certification

NO

Operating Force

9N

Mechanical Life

10000000Cycles

Mounting Orientation

Front

Conduit Entry

M12

COO (Country of Origin):
CN

Honeywell SZL-VL Series Limit Switch, 9N Operating Force, IP67 - SZL-VL-S-H-N-M


This limit switch is a Compact mechanical switching device used to detect position or movement within automated systems. It is intended for front-mounted installation where a Durable enclosure and straightforward actuation are required. The unit employs a TOP pin plunger actuator and is suited to applications demanding defined snap-action contacts and straightforward conduit termination.

Features and Benefits:


• Snap-action contacts give fast, decisive switching response
• 1NO1NC arrangement allows flexible control-circuit design
• IP67 enclosure protects against dust and temporary immersion
• Die-cast metal housing delivers robust environmental protection
• M12 conduit entry and Terminal simplify wiring connection
• Rated for 10 A switching at 380V AC for heavy-duty loads

Applications


• Suitable for position sensing on conveyor end-stops
• Ideal for machine-tool limit detection in production lines
• Used with doors and guards for safety interlock monitoring
• Can be used for actuator travel end detection in presses
• Suitable for monitoring moving parts in material-handling systems

What operating temperatures can it tolerate in cold installations?


It is specified to operate down to −20 °C, allowing use in chilled or unheated environments.

How long can it be expected to switch under mechanical cycling?


The mechanical life is rated at 10,000,000 cycles, supporting frequent actuation in continuous operations.

What force is required to operate the actuator for reliable contact change?


The plunger requires an operating force of 9 N to depress and initiate switching.

How are electrical terminations provided for integration into control panels?


Termination is via an M12 Terminal interface, enabling a standardised conduit/wiring connection.

What approvals support deployment in regulated industrial settings?


It carries recognised approvals including cULus, CCC and CE for use in applicable markets.