Fluke CNX 3000 Handheld LCD Digital Multimeter, 400mA ac Max, 400mA dc Max, 1000V ac Max
- RS Stock No.:
- 765-0419
- Mfr. Part No.:
- Fluke CNX 3000
- Brand:
- Fluke
Alternative
This product is not currently available. Here is our alternative recommendation.
Each
£393.90
(exc. VAT)
£472.68
(inc. VAT)
- RS Stock No.:
- 765-0419
- Mfr. Part No.:
- Fluke CNX 3000
- Brand:
- Fluke
Select all | Attribute | Value |
|---|---|---|
| Brand | Fluke | |
| Multimeter Type | Handheld | |
| Model Number p | CNX 3000 | |
| Display Type | LCD | |
| Functions Measured | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Diode, Frequency, Resistance | |
| Absolute Maximum AC Voltage Measurement | 1000V ac | |
| Absolute Maximum DC Voltage Measurement | 1000V dc | |
| Absolute Maximum DC Current Measurement | 400mA dc | |
| Absolute Maximum AC Current Measurement | 400mA ac | |
| Absolute Maximum Resistance Measurement | 50MΩ | |
| Absolute Maximum Capacitance Measurement | 9.999mF | |
| Maximum Frequency | 1kHz | |
| DC Current Measurement Resolution | 0.01mA dc | |
| AC Current Measurement Resolution | 0.01mA ac | |
| DC Voltage Measurement Resolution | 0.1mV dc | |
| AC Voltage Measurement Resolution | 0.1mV ac | |
| Resistance Measurement Resolution | 100mΩ | |
| Safety Category Level | CAT III, CAT IV | |
| Capacitance Measurement Resolution | 1nF | |
| Length | 207mm | |
| Width | 93mm | |
| Weight | 340g | |
| Height | 47.5mm | |
| Minimum Operating Temperature | -10°C | |
| Dimensions | 207 x 93 x 47.5mm | |
| Safety Category Voltage | 600 V, 1000 V | |
| Battery Type | AA | |
| Maximum Operating Temperature | +50°C | |
| Select all | ||
|---|---|---|
Brand Fluke | ||
Multimeter Type Handheld | ||
Model Number p CNX 3000 | ||
Display Type LCD | ||
Functions Measured AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Diode, Frequency, Resistance | ||
Absolute Maximum AC Voltage Measurement 1000V ac | ||
Absolute Maximum DC Voltage Measurement 1000V dc | ||
Absolute Maximum DC Current Measurement 400mA dc | ||
Absolute Maximum AC Current Measurement 400mA ac | ||
Absolute Maximum Resistance Measurement 50MΩ | ||
Absolute Maximum Capacitance Measurement 9.999mF | ||
Maximum Frequency 1kHz | ||
DC Current Measurement Resolution 0.01mA dc | ||
AC Current Measurement Resolution 0.01mA ac | ||
DC Voltage Measurement Resolution 0.1mV dc | ||
AC Voltage Measurement Resolution 0.1mV ac | ||
Resistance Measurement Resolution 100mΩ | ||
Safety Category Level CAT III, CAT IV | ||
Capacitance Measurement Resolution 1nF | ||
Length 207mm | ||
Width 93mm | ||
Weight 340g | ||
Height 47.5mm | ||
Minimum Operating Temperature -10°C | ||
Dimensions 207 x 93 x 47.5mm | ||
Safety Category Voltage 600 V, 1000 V | ||
Battery Type AA | ||
Maximum Operating Temperature +50°C | ||
RoHS Status: Not Applicable
- COO (Country of Origin):
- US
Fluke CNX Wireless 3000 Digital Multimeter
Compatible with the following Fluke CNX 3000 Series wireless modules and accessories:
AC Voltage Module (RS 765-0425)
AC True-RMS Current Clamp Module (RS 765-0422)
iFlex True-RMS AC Current Clamp Module (RS 765-0413)
K-Type Temperature Module (RS 765-0429)
PC USB Wireless Adapter (RS 765-0438)
The Fluke CNX Wireless test tools (modules) can also communicate with Ti100 and TiR100 Series Thermal Imagers just as they do with the CNX 3000 digital multimeters allowing you to not only see thermal images but take measurements wirelessly from the CNX multimeter and modules and display the results on your camera.
Min / max recording
Four line LCD display with a 4 Hz update rate
Powered by three AA alkaline batteries (supplied) with a life of 300 hours minimum
RF communication uses the 2.4 GHz ISM band with a range of 20 metres
IP54 ingress protection rating
Approvals
Fluke CNX meets Measurement Category 1000 V CAT III and Category IV 600 V safety standards: AC current clamp 600 V CAT III; AC Voltage Module and iFlex Clamp Meters 600 V CAT IV / 1000 CAT III
Electromagnetic compatibility:
EN 61326-1:2006, EN 61326-2-2:2006. ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249, FCCID : T68-FWCS IC:6627A-FWCS
Safety compliance:
US ANSI: ANSI/ISA 61010-1 / (82.02.01): 3rd edition CSA: CAN/CSA-C22.2 No 61010-1-12: 3rd edition CE European: IEC/EN 61010-1:2010
Certifications:
CSA, FCC, CE
Supplied with
1 x A175 crocodile clips
3 x AA alkaline batteries
The CNX Series consists of:
Digital Multimeter (765-0419)
AC Voltage Module (765-0425)
AC True RMS Current Clamp Module (765-0422)
iFlex True RMS AC Current Module (765-0413)
K-Type Temperature Module (765-0429)
USB PC Adapter (765-0438)
These items are available individually and we also supply dedicated kits.
The Fluke CNX 3000 Wireless multimeter can display readings from any three 3 wireless modules, plus the meter measurement, at the same time from up to 20 meters away, on one screen. Add a laptop or PC and review ten measurements at once, remotely.
The wireless enabled modules are dedicated to measure AC voltage, temperature and AC current (choose a standard clamp or iFlex current loop to measure AC current). Mix and match modules to suit your unique measurement needs. The measurements are wirelessly transmitted using the 2.4GHz ISM band to the CNX 3000 multimeter and/or to a PC via the Fluke CNX P3000 USB wireless PC adaptor for live viewing. Each placed module can be identified with the multimeter or PC allowing you to choose the module and view the live readings you need.
In addition to live data viewing from up to ten modules you can also log data within each module for later download to help isolate intermittent events or record signal fluctuations over time.