Recom RK DC-DC Converter, 15V dc/ 66mA Output, 21.6 → 26.4 V dc Input, 1W, Through Hole, +90°C Max Temp -40°C
- RS Stock No.:
- 905-2710
- Mfr. Part No.:
- RK-2415S/H6
- Brand:
- Recom
Bulk discount available
Subtotal (1 unit)*
£8.30
(exc. VAT)
£9.96
(inc. VAT)
FREE delivery for orders over £50.00
In Stock
- 74 unit(s) ready to ship
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
---|---|
1 - 4 | £8.30 |
5 - 9 | £8.05 |
10 - 24 | £7.81 |
25 - 49 | £7.55 |
50 + | £7.30 |
*price indicative
- RS Stock No.:
- 905-2710
- Mfr. Part No.:
- RK-2415S/H6
- Brand:
- Recom
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | Recom | |
Output Voltage | 15V dc | |
Input Voltage Range | 21.6 → 26.4 V dc | |
Power Rating | 1W | |
Input Voltage Nominal | 24 V dc | |
Output Current | 66mA | |
Mounting Type | Through Hole | |
Isolated | Yes | |
Number of Outputs | 1 | |
Output Voltage Adjustment Range | ±5% | |
Package | SIP 7 | |
Isolation Voltage | 4kV dc | |
Depth | 10.2mm | |
Width | 7.05mm | |
Length | 19.65mm | |
Series | RK | |
Load Regulation | 0.1 | |
Maximum Temperature | +90°C | |
Efficiency | 77 → 80% | |
Minimum Temperature | -40°C | |
Standards Met | A12:2011, E-358085, EN 60950-1, EN 60950-1:2006, IEC/EN 60601-1 Certified, IEC/EN 60601-1: 2006, UL 60950-1, UL 94 V-0, UL60950 | |
Select all | ||
---|---|---|
Brand Recom | ||
Output Voltage 15V dc | ||
Input Voltage Range 21.6 → 26.4 V dc | ||
Power Rating 1W | ||
Input Voltage Nominal 24 V dc | ||
Output Current 66mA | ||
Mounting Type Through Hole | ||
Isolated Yes | ||
Number of Outputs 1 | ||
Output Voltage Adjustment Range ±5% | ||
Package SIP 7 | ||
Isolation Voltage 4kV dc | ||
Depth 10.2mm | ||
Width 7.05mm | ||
Length 19.65mm | ||
Series RK | ||
Load Regulation 0.1 | ||
Maximum Temperature +90°C | ||
Efficiency 77 → 80% | ||
Minimum Temperature -40°C | ||
Standards Met A12:2011, E-358085, EN 60950-1, EN 60950-1:2006, IEC/EN 60601-1 Certified, IEC/EN 60601-1: 2006, UL 60950-1, UL 94 V-0, UL60950 | ||
Related links
- Recom RK DC-DC Converter 21.6 → 26.4 V dc Input Through Hole, +90°C Max Temp -40°C
- Recom RK DC-DC Converter 21.6 → 26.4 V dc Input Through Hole, +90°C Max Temp -40°C
- Recom RK DC-DC Converter 21.6 → 26.4 V dc Input Through Hole, +90°C Max Temp -40°C
- Recom RK DC-DC Converter 10.8 → 13.2 V dc Input Through Hole, +90°C Max Temp -40°C
- Recom RO DC-DC Converter 21.6 → 26.4 V dc Input Through Hole, +85°C Max Temp -40°C
- Recom RE DC-DC Converter 21.6 → 26.4 V dc Input Through Hole, +85°C Max Temp -40°C
- Recom RK DC-DC Converter 21.6 → 26.4 V dc Input Through Hole, +85°C Max Temp -40°C
- Recom RK DC-DC Converter 10.8 → 13.2 V dc Input Through Hole, +85°C Max Temp -40°C