Amprobe ACD-14 PLUS Clamp Meter 600 A 600 V dc 600 V ac CAT III
- RS Stock No.:
- 794-3070
- Distrelec Article No.:
- 176-41-260
- Mfr. Part No.:
- ACD-14 PLUS
- Brand:
- Amprobe
Subtotal (1 unit)*
£143.00
(exc. VAT)
£171.60
(inc. VAT)
FREE delivery for orders over £60.00
- 1 left, ready to ship
- Plus 1 left, ready to ship from another location
- Plus 4 left, shipping from 14 October 2026
Units | Per unit |
|---|---|
| 1 + | £143.00 |
*price indicative
Calibration Options:
- Calibration Type:
- UKAS
- RS Stock No.
- 794-4815
Each
£218.00
(exc. VAT)
£261.60
(inc. VAT)
- RS Stock No.:
- 794-3070
- Distrelec Article No.:
- 176-41-260
- Mfr. Part No.:
- ACD-14 PLUS
- Brand:
- Amprobe
Select all | Attribute | Value |
|---|---|---|
| Brand | Amprobe | |
| Product Type | Clamp Meter | |
| Resistance Resolution | 0.1Ω | |
| Maximum AC Voltage Measurement | 600V ac | |
| Maximum DC Voltage Measurement | 600V dc | |
| Maximum Resistance Measurement | 40MΩ | |
| Model Number | ACD-14 PLUS | |
| Minimum Operating Temperature | 0°C | |
| AC Current Resolution | 10mA | |
| AC Voltage Accuracy | ±2% + 5 Digits | |
| AC Voltage Resolution | 1mV ac | |
| Maximum Jaw Opening | 26mm | |
| Resistance Measurement Accuracy | ±(0.8% rdg. + 6 digits) | |
| DC Voltage Resolution | 1 mV dc | |
| AC Current Accuracy | ±(1.9% rdg. + 8 digits) | |
| Clamp Meter Type | AC Current Clamp Meter | |
| DC Voltage Accuracy | ±(0.8% rdg. + 6 digits) | |
| Temperature Measurement Accuracy | ±(2% rdg. + 3°C) | |
| Maximum Operating Temperature | 40°C | |
| Width | 63mm | |
| Height | 32mm | |
| Length | 190mm | |
| Weight | 204g | |
| Standards/Approvals | No | |
| Functions Measured | AC Voltage, AC Current, Capacitance, Resistance, DC Voltage, Temperature | |
| Safety Category Voltage | 600V | |
| Power Source | Battery | |
| Battery Type | Alkaline | |
| Display Type | LCD | |
| Maximum Conductor Size | 28mm | |
| Maximum AC Current Measurement | 600A | |
| Maximum Temperature Measurement | 537°C | |
| Battery Life | 95h | |
| Safety Category Level | CAT III | |
| Select all | ||
|---|---|---|
Brand Amprobe | ||
Product Type Clamp Meter | ||
Resistance Resolution 0.1Ω | ||
Maximum AC Voltage Measurement 600V ac | ||
Maximum DC Voltage Measurement 600V dc | ||
Maximum Resistance Measurement 40MΩ | ||
Model Number ACD-14 PLUS | ||
Minimum Operating Temperature 0°C | ||
AC Current Resolution 10mA | ||
AC Voltage Accuracy ±2% + 5 Digits | ||
AC Voltage Resolution 1mV ac | ||
Maximum Jaw Opening 26mm | ||
Resistance Measurement Accuracy ±(0.8% rdg. + 6 digits) | ||
DC Voltage Resolution 1 mV dc | ||
AC Current Accuracy ±(1.9% rdg. + 8 digits) | ||
Clamp Meter Type AC Current Clamp Meter | ||
DC Voltage Accuracy ±(0.8% rdg. + 6 digits) | ||
Temperature Measurement Accuracy ±(2% rdg. + 3°C) | ||
Maximum Operating Temperature 40°C | ||
Width 63mm | ||
Height 32mm | ||
Length 190mm | ||
Weight 204g | ||
Standards/Approvals No | ||
Functions Measured AC Voltage, AC Current, Capacitance, Resistance, DC Voltage, Temperature | ||
Safety Category Voltage 600V | ||
Power Source Battery | ||
Battery Type Alkaline | ||
Display Type LCD | ||
Maximum Conductor Size 28mm | ||
Maximum AC Current Measurement 600A | ||
Maximum Temperature Measurement 537°C | ||
Battery Life 95h | ||
Safety Category Level CAT III | ||
RoHS Status: Exempt
- COO (Country of Origin):
- TW
Fluke Clamp Meter, 600A Maximum AC Current Measurement, 600V Maximum AC Voltage Measurement - ACD-14 PLUS
Features and Benefits:
• 26mm jaw opening permits single-conductor clamping in confined spaces
• AC voltage accuracy ±1.5% rdg+5 digits enables precise voltage diagnostics
• Maximum AC current measurement 600A supports heavy current circuits
• Battery life 95h ensures sustained field operation between replacements
• Temperature probe compatibility allows on-site thermal assessments
Applications
• Ideal for measuring inrush and ionisation currents in boilers
• Used for maintenance of industrial distribution up to 600V CAT III
• Can be used for component testing including capacitance checks
• Suitable for verifying continuity and resistance in control panels
What measurement ranges are available for current and voltage?
How does the instrument handle low-level ionisation current detection?
Which display and memory functions assist dynamic measurements?
What temperature range can be measured with the supplied probe?
What safety standards and pollution degree apply to its use?
Supplied with
Related links
- Amprobe ACD-14 PLUS Clamp Meter 600 A 600 V dc 600 V ac CAT III, UKAS
- Amprobe ACD-14 PLUS Clamp Meter 600 A 600 V dc 600 V ac CAT III, RSCAL
- Amprobe ACD-10 PLUS Clamp Meter 600 A ac 600 V dc 600 V ac CAT III
- Amprobe ACD-10 PLUS Clamp Meter 600 A ac 600 V dc 600 V ac CAT III, UKAS
- Amprobe ACD-10 PLUS Clamp Meter 600 A ac 600 V dc 600 V ac CAT III, RSCAL
- Beha-Amprobe AMP 210 Clamp Meter RSCAL
- Beha-Amprobe AMP 210 Clamp Meter UKAS
- Beha-Amprobe AMP 220 Clamp Meter, 600 A dc 600 A ac 600 V dc 600 V ac CAT III Non-Contact Voltage Detector