Select all | Attribute | Value |
|---|---|---|
| Brand | Fluke | |
| Absolute Maximum DC Current Measurement | 100mA dc | |
| Absolute Maximum DC Voltage Measurement | 30V dc | |
| Model Number | 773 | |
| DC Current Measurement Resolution | 10µA | |
| Best DC Current Accuracy | ±(0.2% rdg +5 Digits) | |
| Clamp Meter Type | DC Current Clamp Meter | |
| Jaw Capacity Busbars | 4.5mm | |
| Functions Measured | DC Voltage | |
| Best DC Voltage Accuracy | 0.2% + 2 Digits | |
| DC Voltage Measurement Resolution | 10mV | |
| Dimensions | 248 x 76 x 41mm | |
| Length | 248mm | |
| Display Type | LCD | |
| Maximum Operating Temperature | +50°C | |
| Battery Type | AA | |
| Minimum Operating Temperature | -10°C | |
| Width | 76mm | |
| Battery Life | 12 h | |
| Weight | 420g | |
| Height | 41mm | |
| Maximum Conductor Size | 4.5mm | |
| Power Source | Battery | |
| Select all | ||
|---|---|---|
Brand Fluke | ||
Absolute Maximum DC Current Measurement 100mA dc | ||
Absolute Maximum DC Voltage Measurement 30V dc | ||
Model Number 773 | ||
DC Current Measurement Resolution 10µA | ||
Best DC Current Accuracy ±(0.2% rdg +5 Digits) | ||
Clamp Meter Type DC Current Clamp Meter | ||
Jaw Capacity Busbars 4.5mm | ||
Functions Measured DC Voltage | ||
Best DC Voltage Accuracy 0.2% + 2 Digits | ||
DC Voltage Measurement Resolution 10mV | ||
Dimensions 248 x 76 x 41mm | ||
Length 248mm | ||
Display Type LCD | ||
Maximum Operating Temperature +50°C | ||
Battery Type AA | ||
Minimum Operating Temperature -10°C | ||
Width 76mm | ||
Battery Life 12 h | ||
Weight 420g | ||
Height 41mm | ||
Maximum Conductor Size 4.5mm | ||
Power Source Battery | ||
RoHS Status: Exempt
Fluke 773 Milliamp Process Clamp Meters
Here are some specific ways the Fluke 773 clamp meter will help you:
Measures low level dc current
Correlate process indication with real physical value
Measure output signals from transmitters without breaking the loop
Maintain and troubleshoot process and automation equipment without breaking the loop
No disruption to the process
Detachable clamp with extension cable
Measurements in tight locations
Enables measurements in difficult situations
Measurement Spotlight
Illuminates hard to see wires in dark enclosures
Measurement process is easier and quicker
Measure up to 99.9 mA range non-contact
Wide range of measurements
Measures 10 to 50 mA signals in older control systems
Automatic power off
After 15 minutes and 2 minute automatic off for backlight and spotlight
Saves battery life
Want simultaneous mA source/measure? Consider the Fluke 773 Milliamp Clamp Meter.
Features and Benefits
0.01 mA resolution and sensitivity
Measure 4 to 20 mA signals without breaking the loop
Measure mA signals for PLC and control system analog I/O
Dual backlit display with both mA measurement and percent of 4 to 20 mA span
Measurement Spotlight illuminates hard to see wires in dark enclosures
Detachable clamp with extension cable for measurements in tight locations
Measure 10 to 50 mA signals in older control systems using the 99.9 mA range
Automatically change the 4 to 20 mA output for remote testing
Power saving features, auto-off, backlight timeout extend battery life
Hold function captures and displays changing measurements
Measure 4 to 20 mA signals with in-circuit measurement
Simultaneous mA in-circuit measurement with 24V loop power for powering and testing transmitters
Source 4 to 20 mA signals for testing control system I/O or I/Ps
mA output linear ramp or 25% step output
Automatically change the 4 to 20 mA output for remote testing
Fluke 773 additional features:
Source dc voltage to test input devices that accept a 1 to 5 volt or 0 to 10 volt signal
Scaled mA output corresponds to the 4 to 20 mA signal measured by the mA clamp enables a logging DMM or other device to record the 4 to 20 mA signal without breaking the loop mA in/out: simultaneously measure the mA signal with the clamp and source a mA signal
Voltage output linear ramp or 25 % step output
Automatically change the voltage output for remote testing
Note
Supplied with
Related links
- Fluke 773 Clamp Meter, 100mA dc With RS Calibration
- Fluke 773 Clamp Meter, 100mA dc With UKAS Calibration
- Fluke 771 Clamp Meter, 100mA dc
- Fluke 772 Clamp Meter, 100mA dc With RS Calibration
- Fluke 772 Clamp Meter, 100mA dc
- Fluke 772 Clamp Meter, 100mA dc With UKAS Calibration
- Fluke 771 Clamp Meter, 100mA dc With RS Calibration
- Fluke 771 Clamp Meter, 100mA dc With UKAS Calibration