An oscilloscope is considered to be the most used instrument for electrical engineers who need to measure electrical characteristics of electronic devices but you also need at least one probe.
Things to consider when choosing probes
• Ensure the probe's input connector matches the connector on your scope
• Choose a probe whose input resistance and capacitance match the input resistance and capacitance of your scope - matching is critical for guaranteeing proper signal transfer and signal accuracy
The best approach, for matching a probe with a scope, is to first choose a probe whose capacitance is within the range of your scope and then fine-tune the probe's capacitance by adjusting its compensation network using the probe's trimmer capacitor.
The 1X probes are suitable for many low frequency applications. They typically offer the same input impedance of the oscilloscope which is normally 1 M Ohm. The most common type of probe with a built in attenuator gives an attenuation of ten, and it is known as a 10X oscilloscope probe
Types of probes
Passive probes are the most commonly used probes for taking measurements. They are easy to use, relatively inexpensive, and fairly rugged. Available in the following configurations:
• 1´: no attenuation
• 10´: factor-of-10 attenuation
• 100´: factor-of-100 attenuation
• 1000´: factor-of-1000 attenuation
Attenuation probes serve to multiply the voltage measurement range of the oscilloscope by using an internal resistor that, when used in conjunction with the input resistance of the scope, creates a voltage divider. Useful for the following reasons:
• It allows for the measurement of a signal that might exceed the limits of the oscilloscope.
• The attenuation circuitry results in higher resistance and lower capacitance, which is important for high-frequency measurements.
Active probes contain active components, such as FETs or amplifiers. Commonly used for taking high-speed measurements (>500 MHz) or on high-impedance circuits. One limitation is their limited voltage range.
Differential probes are popular for measuring high-frequency signals or signals of very low amplitude.
A current probe measures the electrical current flowing through a conductor.
Tips
• Always use an appropriate probe tip and/or probe tip adapter whenever possible
• Keep ground leads short

...
Read more Read less

Filters

Viewing 41 - 60 of 209 products
Results per page
Description Price Probe Type Attenuation Bandwidth Maximum Common Mode Input Voltage Connector Type Model Number p Number of Probes Safety Category Level Safety Category Voltage Series Safety Category Rise Time
RS Stock No. 733-6145
Mfr. Part No.N2791A
£606.00
Each
Units
Differential 1:10, 1:100 25MHz 700V BNC N2791A - CAT II 1000V ac N CAT II 1000 V ac 14ns
RS Stock No. 745-0702
Mfr. Part No.PPE6KV
£1,050.00
Each
Units
High Voltage, Passive 1:1000 400MHz - BNC PPE6KV - CAT I - PEE CAT I -
RS Stock No. 726-0038
Mfr. Part No.TPP0200
BrandTektronix
£62.00
Each
Units
Passive 1:10 200MHz 300V BNC TPP0200 - CAT II 300V TPP CAT II 300 V -
RS Stock No. 752-7357
Mfr. Part No.THDP0200
BrandTektronix
£1,980.00
Each
Units
Differential, High Voltage 1:50, 1:500 200MHz 1.5kV BNC THDP0200 - CAT II, CAT III 600 V, 1000 V THD CAT II 1000 V, CAT III 600 V 1.8ps
RS Stock No. 734-5013
Mfr. Part No.P5100A
BrandTektronix
£533.00
Each
Units
Passive 1:100 500MHz 1kV - P5100A - CAT II 1000V ac 5000 CAT II 1000 V ac 700ps
RS Stock No. 209-7860
Mfr. Part No.P6243
BrandTektronix
£2,254.20
Each
Units
Active 1:10 1GHz - BNC P6243 - - - - - 350ps
RS Stock No. 734-5029
Mfr. Part No.P5200A
BrandTektronix
£1,070.00
Each
Units
Differential, High Voltage 1:50, 1:500 50MHz 1kV - P5200A - CAT II 1000V P52XXA CAT II 1000 V -
RS Stock No. 851-3087
Mfr. Part No.HVP120
£430.00
Each
Units
Passive 1:100 400MHz - BNC HVP120 - CAT I, CAT II 1000 Vrms, 6000 V HVP CAT I 6000 V, CAT II 1000 Vrms 900ps
RS Stock No. 901-0970
Mfr. Part No.PK400-0
£6.136
Each (In a Pack of 22)
Units
Gripper - - - - - 22 - - - - -
RS Stock No. 811-1246
Mfr. Part No.VPS420-V
BrandFluke
£228.00
Each
Units
Passive 1:100 150MHz 300V - VPS420 - CAT III, CAT IV 600 V, 1000 V VPS420 CAT III 1000 V, CAT III 2000 V, CAT IV 1200 V, CAT IV 600 V -
RS Stock No. 726-0041
Mfr. Part No.TPP0201
BrandTektronix
£62.00
Each
Units
Passive 1:10 200MHz 300V BNC TPP0201 - CAT I, CAT II 300 V ac, 300 V, 400 V ac TPP CAT I 400 V ac, CAT II 300 V, CAT II 300 V ac 2.3ns
RS Stock No. 898-6766
Mfr. Part No.TA057
£269.00
Each
Units
Active, Differential 1:20, 1:200 25MHz 1kV - - 2 CAT III 1000 Vrms, ±1400 V - 1000 Vrms, CAT III ±1400 V -
RS Stock No. 734-5026
Mfr. Part No.P5205A
BrandTektronix
£1,570.00
Each
Units
Differential, High Voltage 1:50, 1:500 100MHz 1kV - P5205A - CAT II 1000V P52XXA CAT II 1000 V -
RS Stock No. 668-7151
Mfr. Part No.P6245
BrandTektronix
£3,120.00
Each
Units
Active 1:10 1.5GHz - BNC P6245 - - - - - 250ps
RS Stock No. 448-4351
Mfr. Part No.15120
BrandTestec
£444.47
Each
Units
Active, Differential 1:100, 1:1000 100MHz 1kV BNC TT-SI 9110 - CAT III 1000 V ac, 1400 V ac/dc SI CAT III 1000 V ac, CAT III 1400 V 3.5ns
RS Stock No. 661-3292
Mfr. Part No.TDP0500
BrandTektronix
£3,780.00
Each
Units
Differential, High Voltage 1:5, 1:50 500MHz 30V - TDP0500 - - - TDP - 700ps
RS Stock No. 898-6769
Mfr. Part No.TA058
£339.00
Each
Units
Active, Differential 1:10 50MHz 600V - - 2 CAT I 600 Vrms, ±700 V - 600 Vrms, CAT I ±700 V -
RS Stock No. 678-4000
Mfr. Part No.PMS211A
BrandPMK
£49.66
Each
Units
Passive 1:10 150MHz - BNC PMS211A - CAT II 300V PMS CAT II 300 V 2.4ns
RS Stock No. 575-585
Mfr. Part No.P2221
BrandTektronix
£133.00
Each
Units
Passive 1:1, 1:10 200MHz - - P2221 - CAT II 150 V, 300 V - CAT II 15 V, CAT II 300 V -
RS Stock No. 801-4868
Mfr. Part No.AP031
£525.00
Each
Units
Differential 1:10, 1:100 25MHz 700V BNC AP031 - CAT III 1000V - CAT III 1000 V 14ns
Related Products
The Teledyne Le Croy oscilloscope probe is affordable ...
Description:
The Teledyne Le Croy oscilloscope probe is affordable and optimally designed for measurement of small signals floating on an HV bus in power electronics designs or for EMC, EFT, ESD and RF immunity testing sensor monitoring. It far surpasses the measurement capabilities and signals fidelity of both conventional HV differential ...
Teledyne Le Croy’s HVD3605A series of high voltage ...
Description:
Teledyne Le Croy’s HVD3605A series of high voltage differential probes cover the fullest range of applications. Featuring a 6kV, 100 MHz High Voltage Differential Probe with Auto Zero Disconnect, the HVD3605A series are a reliable and versatile tool you can trust. The 1% gain accuracy coupled with exceptional common-mode rejection ...
The Tektronix single-ended Active FET oscilloscope probe provides ...
Description:
The Tektronix single-ended Active FET oscilloscope probe provides excellent high-speed electrical and mechanical performance required for digital system designs. It is specifically designed for direct connection to oscilloscopes with the Tek VP probe interface.Note:TAP1500 includes individual probe case Supplied with:Ground leads AdaptorsColour-coding clips Solderable probe tips Test tips User manual ...
The Tektronix differential active oscilloscope probe offers truer ...
Description:
The Tektronix differential active oscilloscope probe offers truer signal reproduction and fidelity for high-frequency measurements. With ultra-low input capacitance and the versatile device under test connection capabilities, it has excellent high-speed electrical and mechanical performance required for today’s digital system designs. It is specifically designed for use and direct connection ...