Fluke 805 FC + 820-2 Vibration Meter - Velocity, Acceleration, Displacement
- RS Stock No.:
- 201-2098
- Mfr. Part No.:
- FLUKE-805 FC/820-2
- Brand:
- Fluke
Subtotal (1 unit)*
£2,832.00
(exc. VAT)
£3,398.40
(inc. VAT)
FREE delivery for orders over £60.00
In Stock
- 1 unit(s) ready to ship
- Plus 1 unit(s) ready to ship from another location
- Plus 1 unit(s) shipping from 22 May 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | £2,832.00 |
*price indicative
- RS Stock No.:
- 201-2098
- Mfr. Part No.:
- FLUKE-805 FC/820-2
- Brand:
- Fluke
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Fluke | |
| Measurement Parameters | Velocity, Acceleration, Displacement | |
| Product Type | Vibration Meter | |
| Maximum Acceleration | 50g | |
| Minimum Acceleration | 0.01g | |
| Plug Type | USB 2.0 | |
| Minimum Operating Temperature | -20°C | |
| Battery Life | 250Measurements | |
| Maximum Operating Temperature | 50°C | |
| Standards/Approvals | EN 6100042, CISPR 11, EN 6100043, Class A | |
| Battery Type | 2 x AA | |
| Model Number | 805 FC + 820-2 | |
| Select all | ||
|---|---|---|
Brand Fluke | ||
Measurement Parameters Velocity, Acceleration, Displacement | ||
Product Type Vibration Meter | ||
Maximum Acceleration 50g | ||
Minimum Acceleration 0.01g | ||
Plug Type USB 2.0 | ||
Minimum Operating Temperature -20°C | ||
Battery Life 250Measurements | ||
Maximum Operating Temperature 50°C | ||
Standards/Approvals EN 6100042, CISPR 11, EN 6100043, Class A | ||
Battery Type 2 x AA | ||
Model Number 805 FC + 820-2 | ||
- Contains SVHC - 1,2-dimethoxyethane; ethylene glycol dimethyl ether (EGDME) - CAS No. 110-71-4
- Datasheet - FLUKE-805 FC
- Instruction Sheet - FLUKE-805 FC
- Technical Datasheet - FLUKE-820-2
- Instruction Sheet - FLUKE-820-2
- UN38.3 Lithium Battery Test Summary
- Guide - FLUKE-805 FC
- Application Note - FLUKE-805 FC
- Guide - FLUKE-820-2
- Application Note - FLUKE-820-2
- Brochure - The Tools
- Brochure - Mechanical Troubleshooting
- COO (Country of Origin):
- US
Fluke Vibration Meter, 50g Maximum Acceleration, Velocity Measurement - FLUKE-805 FC/820-2
This vibration metre is a handheld screening tool for frontline mechanical troubleshooting, designed to provide repeatable severity‑scaled readings of overall vibration and bearing condition. It measures across low and high frequency bands, offers on‑board data storage and USB connectivity, and integrates temperature sensing to extend diagnostic capability for industrial maintenance rounds.
Features & Benefits
• Measures overall vibration from 10Hz to 1000Hz for broad machinery assessment
• High‑frequency CF+ assesses bearing condition from 4000Hz to 20000Hz
• Peak measurement capacity up to 50g for high‑impact events
• Stores up to 3500 measurements for onsite trending and review
• USB 2.0 export enables Excel trending with pre‑built templates
• AA battery operation delivering approximately 250 measurements per charge
• High‑frequency CF+ assesses bearing condition from 4000Hz to 20000Hz
• Peak measurement capacity up to 50g for high‑impact events
• Stores up to 3500 measurements for onsite trending and review
• USB 2.0 export enables Excel trending with pre‑built templates
• AA battery operation delivering approximately 250 measurements per charge
**Applications**
• Suitable for condition checks on centrifugal pumps and chillers during rounds
• Ideal for screening bearings on gearboxes and motor‑driven equipment
• Used with compressors and blowers to detect developing vibration faults
• Can be used for spindle and machine‑tool vibration monitoring in workshops
• Suitable for monitoring fans and cooling‑tower drive assemblies
• Ideal for screening bearings on gearboxes and motor‑driven equipment
• Used with compressors and blowers to detect developing vibration faults
• Can be used for spindle and machine‑tool vibration monitoring in workshops
• Suitable for monitoring fans and cooling‑tower drive assemblies
What amplitude units can I view on the instrument?
You can display acceleration, velocity and displacement using g, m/s2, in/s, mm/s, mils and mm units.
How does the device support external sensing?
It accepts an external accelerometer via an SMB connector and supplies 20–22Vdc with up to 5mA bias current.
What environmental limits should I observe for field use?
Operate between −20°C and 50°C with 10%–95% RH non‑condensing and up to 3048m altitude.
How is electromagnetic compatibility addressed?
The unit meets EN 61000‑4‑2 electrostatic discharge and EN 61000‑4‑3 electromagnetic immunity with radiated emission CISPR11 Class A.
What onboard hardware assists measurements in low light?
An integrated torch illuminates measurement points while an infrared spot sensor measures surface temperature from −20°C to 200°C.
Related links
- Fluke 805 FC + 805 ES Vibration Meter - Velocity Displacement
- Fluke 805 Vibration Meter - Acceleration Velocity
- Fluke 805ES Vibration Sensor Vibration Meter - Acceleration Velocity
- Extech VB450 Vibration Meter - Velocity Displacement
- Castle GA2008 Vibration Meter - Velocity Displacement 1 Axis
- Castle GA2002 Vibration Meter - Velocity Acceleration 1 Axis
- Extech VB400 Vibration Meter - Velocity, Acceleration
- Extech Vibration Meter - Velocity Acceleration