Honeywell Bi-Metallic Thermostat, Closes at 135 °C, 150 °C Max Open or Close On Rise, Automatic Reset, SPST, 10 A,

Subtotal (1 pack of 25 units)*

£647.55

(exc. VAT)

£777.05

(inc. VAT)

Add to Basket
Select or type quantity
In Stock
  • 925 unit(s) ready to ship
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units
Per unit
Per Pack*
25 +£25.902£647.55

*price indicative

RS Stock No.:
339-724A
Mfr. Part No.:
2455R 82-235 L150C
Brand:
Honeywell
Find similar products by selecting one or more attributes.
Select all

Brand

Honeywell

Minimum Operating Temperature

0°C

Product Type

Thermostat

Maximum Operating Temperature

150°C

Closing Temperature

135°C

Thermostat Type

Bi-Metallic

Contact Configuration

SPST

Contact AC Voltage

250V ac

Terminal Type

Solder Tab

Contact Current

10A

Standards/Approvals

VDE, Mil-PRF-24236, NASA certified, MIL-STD-202, UL, CSA

Series

2455R

Hazardous Area Certification

NO

Switch Function

Open or Close On Rise

Mount Type

Through Hole

Reset Type

Automatic

COO (Country of Origin):
CN

Honeywell 2455R Series Thermostat, 135°C Closing Temperature, 10A Contact Current - 2455R--00820235


This thermostat is a Compact commercial thermal switch designed to operate as a temperature‑actuated control in electrical and mechanical systems. It monitors temperature and changes contact state on rising temperature to protect circuits or trigger downstream control logic in non‑hazardous environments.

Features and Benefits:


• Opens or closes on temperature rise to control heating processes
• Automatic reset restores circuit continuity after cooling
• SPST contact supports single‑circuit switching at rated load
• 10 A contact current enables moderate‑power switching applications
• 250V AC contact rating suitable for standard mains circuits
• Through‑hole mount with solder tab terminals for PCB assembly

Applications


• Suitable for thermal protection in industrial control panels
• Ideal for temperature monitoring in HVAC equipment
• Used with motors to prevent overheating during prolonged duty
• Can be used for temperature safety in commercial appliances
• Suitable for integration into automated test rigs requiring thermal cutover

What temperature range can it reliably operate within?


It functions between 0 °C minimum ambient and 150 °C maximum operating temperature, with the switching point set to trigger at 135 °C.

How is the unit reset after it actuates?


The device returns to its original contact state automatically once the temperature falls below the specified threshold.

Which mounting and electrical connection methods are provided?


It mounts via a through‑hole configuration and uses solder tab terminals for direct PCB or wiring connection.

Is this suitable for use in explosive atmospheres?


It has no hazardous‑area certification and is intended for use in non‑hazardous locations only.

Approvals

UL recognised component, CSA Certified