Carroll & Meynell 1 Site Transformer 3 kVA, 230 V ac Primary, 110 V ac Secondary, 31.81 A O/P
- RS Stock No.:
- 436-8833
- Mfr. Part No.:
- CM5000/WM0
- Brand:
- Carroll & Meynell
Subtotal (1 unit)*
£783.33
(exc. VAT)
£940.00
(inc. VAT)
FREE delivery for orders over £50.00
Temporarily out of stock
- 4 unit(s) shipping from 25 February 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | £783.33 |
*price indicative
- RS Stock No.:
- 436-8833
- Mfr. Part No.:
- CM5000/WM0
- Brand:
- Carroll & Meynell
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Carroll & Meynell | |
| Product Type | Site Transformer | |
| Primary Voltage | 230 V ac | |
| Secondary Voltage | 110 V ac | |
| Electrical Phase | 1 | |
| Output Current | 31.81A | |
| Series | CM5000/WM0 | |
| Mount Type | Wall | |
| Plug Type | Hard Wire L-N-E | |
| Power | 3kVA | |
| Maximum Operating Temperature | 200°C | |
| Weight | 35kg | |
| Length | 350mm | |
| Width | 460 mm | |
| Depth | 330mm | |
| Standards/Approvals | BSEN 61558-2-23 | |
| Maximum Operating Frequency | 60Hz | |
| Minimum Operating Frequency | 50Hz | |
| Select all | ||
|---|---|---|
Brand Carroll & Meynell | ||
Product Type Site Transformer | ||
Primary Voltage 230 V ac | ||
Secondary Voltage 110 V ac | ||
Electrical Phase 1 | ||
Output Current 31.81A | ||
Series CM5000/WM0 | ||
Mount Type Wall | ||
Plug Type Hard Wire L-N-E | ||
Power 3kVA | ||
Maximum Operating Temperature 200°C | ||
Weight 35kg | ||
Length 350mm | ||
Width 460 mm | ||
Depth 330mm | ||
Standards/Approvals BSEN 61558-2-23 | ||
Maximum Operating Frequency 60Hz | ||
Minimum Operating Frequency 50Hz | ||
- COO (Country of Origin):
- GB
Single Phase, 230Vac Input, 110Vac Output Transformers
High quality wall mounting safety isolating transformers designed to ensure safe electrical distribution for power tools etc in industrial, garage and other fixed installations.
Double wound
110V secondaries centre tapped to earth to minimise shock risk
Sheet steel IP22 type wall mounting enclosure
Re settable thermal cut out trip in primary circuit to prevent overload
Thermal safety overload fuse embedded into primary winding
20mm conduit entry on both sides of case
Note
Tool rating is defined in BSEN 61558-2-23 as 5 minutes on and 15 minutes off. Maximum output must not exceed 16A per socket outlet.
Standards
BSEN 61558-2-23
Related links
- Carroll & Meynell 5000VA Site Transformer ± 55V ac Secondary, 31.81A O/P
- Carroll & Meynell Single Phase 3kVA Site Transformer 230V ac Secondary, 13A O/P
- Carroll & Meynell Single Phase 3kVA Site Transformer 230V Secondary
- Carroll & Meynell Single Phase 2.5kVA Site Transformer ±55V ac Secondary 2 x 16 A O/P
- Carroll & Meynell Single Phase 375VA Site Transformer 110V ac Secondary, 3A O/P
- Carroll & Meynell 3kVA Site Transformer 230V Secondary, 2 x 16A O/P
- Carroll & Meynell 3kVA Site Transformer ±55V ac Secondary, 27A O/P
- Carroll & Meynell Single Phase 5kVA Site Transformer ±55V ac Secondary