Schneider Electric Dual-Channel Two Hand Control Safety Relay, 115 → 230V ac, 2 Safety Contacts
- RS Stock No.:
- 812-3909
- Mfr. Part No.:
- XPSBAE3920P
- Brand:
- Schneider Electric
Unavailable
RS will no longer stock this product.
Alternative
This product is not currently available. Here is our alternative recommendation.
Each
£150.90
(exc. VAT)
£181.08
(inc. VAT)
- RS Stock No.:
- 812-3909
- Mfr. Part No.:
- XPSBAE3920P
- Brand:
- Schneider Electric
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | Schneider Electric | |
Supply Voltage | 115 → 230V ac | |
Number of Channels | 2 | |
Safety Contacts | 2 | |
Function | Two Hand Control | |
Auxiliary Contacts | 1 | |
Range | Preventa | |
Safety Category ISO 13849-1 | 1 | |
PL ISO 13849-1 | c | |
SIL IEC 61508 | 1 | |
Terminal Type | Screw | |
Width | 114mm | |
Depth | 99mm | |
Series | XPS BA | |
Length | 22.5mm | |
Performance Level | c | |
Select all | ||
---|---|---|
Brand Schneider Electric | ||
Supply Voltage 115 → 230V ac | ||
Number of Channels 2 | ||
Safety Contacts 2 | ||
Function Two Hand Control | ||
Auxiliary Contacts 1 | ||
Range Preventa | ||
Safety Category ISO 13849-1 1 | ||
PL ISO 13849-1 c | ||
SIL IEC 61508 1 | ||
Terminal Type Screw | ||
Width 114mm | ||
Depth 99mm | ||
Series XPS BA | ||
Length 22.5mm | ||
Performance Level c | ||
- COO (Country of Origin):
- DE
Schneider Electric Preventa XPS Series Safety Relay for a Two Hand Control Station.
Schneider Electric Preventa XPS BAE safety relay provides you with the ultimate solution for safety relay electrical monitoring function. Designed to be used with Two-hand control stations ensuring your protection from and injuries to your hands keeping your hands away from the movement area complying with EN 574/ISO 13851.
Two Hand Control Station Operation.
- Two hand control stations must be designed and installed so that they cannot be activated involuntarily or easily rendered inoperative. Depending on the application, the requirements of type C standards specific to the machinery involved must be met.
- To initiate a dangerous movement, both operators (two-hand control pushbuttons) must be activated within an interval y 0.5 s (synchronous activation). If one of the two pushbuttons is released during a dangerous operation, the control sequence is cancelled.
- Resumption of the dangerous operation is possible only if both pushbuttons are returned to their initial position and reactivated within the required time interval.
- The safety distance between the control units and the hazardous zone must be sufficient to ensure that when only one operator is released, the hazardous zone cannot be reached before the dangerous movement has been completed or stopped.
- Maximum achievable safety level b PL c/Category 1 conforming to EN/ISO 13849-1 b SILCL1 conforming to EN/IEC 62061 Product certifications b UL b CSA b TÜV.
Features.
- Monitoring two-hand control station type IIIA
- Captive screw clamp terminals
- 2 LEDs for signalling
- 35mm symmetrical DIN rail mounted
Standards
EN/IEC 60204-1, EN/IEC 60947-5-1, EN/ISO 13849-1, EN 62061, EN 574 type III A, EN 60947-01.
XPSBAE3920P Schneider Electric Preventa Safety Relay Module, Two Hand Control IIIA.
- Preventa safety module XPSBAE.
- For electrical monitoring of two-hand control stations.
- Monitoring two-hand control station type IIIA
- Captive screw clamp terminals.
- 1 NO (volt free)1
- 1 NC additional circuit.
- Rated Supply voltage 115 - 230 V ac.
- Frequency 50 to 60 Hz.
- Maximum power consumption (VA) 3.3 VA.
- Inputs 1 NC + NO.
- Breaking 3 A at 24 V (DC-13).
- Minimum output current 10 MA (relay output).
- Minimum output voltage 17 V (relay output).
- Response time 20 Ms (input open).
- 2 LEDs.
- Mounting 35 mm DIN rail.
- Net weight 0.1 Kg.
Certification.
- CSA UL TÜV
Related links
- Schneider Electric Two Hand Control Safety Relay 2 Safety Contacts
- Wieland safeRELAY SNZ 1022 Safety Relay 115 → 230V ac, Dual-Channel 2 Safety Contacts
- Schneider Electric Two Hand Control Safety Relay 2 Safety Contacts
- Schneider Electric Dual-Channel Speed/Standstill Monitoring Safety Relay 2 Safety Contacts
- Schneider Electric Preventa XPS BCE 1 Auxiliary Contacts Safety Relay 230V ac 2 Safety Contacts
- Wieland safeRELAY SNO 4083 Safety Relay 115 → 230V ac, Dual-Channel 3 Safety Contacts
- Schneider Electric XPSU 8 Auxiliary Contacts Safety Relay 24V ac/dc, Dual-Channel 2 Safety Contacts
- Pilz 777303 Safety Relay 24V ac/dc, Single/Dual-Channel 2 Safety Contacts