Allen Bradley Guardmaster MSR138.1DP 115 V ac Safety Relay Single Channel With 2 Safety Contacts

Technical Reference
Legislation and Compliance
RoHS Status: Not Applicable
COO (Country of Origin): DE
Product Details

Minotaur MSR138.1DP, Dual Channel with Immediate and Delayed Outputs

Can be connected in four different input wiring configurations: 1 N/C, 2N/C, or 2 PNP connections from a light curtain
2 N/O immediate safety rated outputs, 2 N/O delayed safety outputs and 1 N/C delayed safety output
Stop category 0 and 1
Light curtain, E-stop, Safety Gate inputs
Cross fault monitoring
Monitored or automatic reset
Removable terminals
Cat. 4 per EN954-1

Specifications
Attribute Value
Supply Voltage 115 V ac
Number of Channels 1
Auxiliary Contacts 1
Function Light Beam/Curtain, Safety Switch/Interlock
Safety Contacts 2
Range Minotaur
Reset Method Automatic, Manual, Monitored
Terminal Type Screw
Length 114.5mm
Depth 45mm
Width 99mm
1 In stock for FREE next working day delivery
Price Each
£ 245.00
(exc. VAT)
£ 294.00
(inc. VAT)
Units
Per unit
1 +
£245.00
Related Products
2 N/O instantaneous outputs provide stop category 0, ...
Description:
2 N/O instantaneous outputs provide stop category 0, 3 N/O timed contacts provide stop category 1 by allowing controlled deceleration of the motor until a complete stop is achieved4 solid state outputs for PLC signalling Monitored start button feature Delay time: 0 – 30 s. adjustable in 12 steps by ...
Guardmaster Safety Relays can monitor a broad range ...
Description:
Guardmaster Safety Relays can monitor a broad range of safety devices in a variety of applications. These single-function relays can achieve most of the functions safety systems require, to help simplify purchasing and parts management. These relays are designed to meet new functional safety standards, such as ISO 13849-1 or ...
Ensures correct switching of up to 3 contactors ...
Description:
Ensures correct switching of up to 3 contactors with monitoring Fail-safe internal monitoring Single channel input for use with interlock switches and emergency stop buttons. 3 uncommitted safety output circuits and provides a contactor monitoring facility and auxiliary output for indication purposes Power failure on safety critical internal faults result ...
EC type approved (applies when Safedge profiles are ...
Description:
EC type approved (applies when Safedge profiles are used in conjunction with a Safedge Evaluator)May be cut to size and fit Corner and straight connectors are "active" components - no "dead" zones The Safedge Evaluator monitors the status of the Safedge profile and provides an output of two fully cross ...