SICK T4000 Safety Switch, Plastic

Subtotal (1 unit)*

£1,111.20

(exc. VAT)

£1,333.44

(inc. VAT)

Add to Basket
Select or type quantity
Stocked by manufacturer
  • Ready to ship from 11 January 2027
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units
Per unit
1 +£1,111.20

*price indicative

RS Stock No.:
285-4319
Mfr. Part No.:
T4000-1RCA04
Brand:
SICK
Find similar products by selecting one or more attributes.
Select all

Brand

SICK

Product Type

Safety Switch

Actuator Included

No

Housing Material

Plastic

Series

T4000

Contact AC Voltage

60V ac

Contact DC Voltage

24V dc

Minimum Operating Temperature

0°C

IP Rating

IP20

Switch Contact Current

300mA

Hazardous Area Certification

No

Maximum Operating Temperature

55°C

Depth

99mm

Standards/Approvals

CE

Length

114mm

Width

45mm

COO (Country of Origin):
DE

SICK T4000 Series Safety Switch, IP20, 24V DC Supply Voltage - T4000-1RCA04


This safety switch is a non-contact interlock designed for machine safeguarding in non-hazardous areas. It operates from a 24V DC supply and provides two safe relay outputs to monitor guard position and trigger safety functions. The unit is housed in a plastic enclosure and is intended for installations requiring high coding level actuator recognition and category 4 safety performance.

Features and Benefits:


• Category 4 safety meets stringent control system requirements
• PL e performance delivers the highest machine safety level
• 0.3A contact current provides low-power switching capability
• Response time ≤450ms supports timely safety reactions
• Protection class III allows safe low-voltage operation

Applications


• Suitable for safeguarding access doors on production lines
• Ideal for integration with safety evaluation units
• Used for monitoring guards in assembly machinery
• Can be used for non-hazardous area interlock functions

What outputs are provided for safety integration?


It provides two normally open relay safety outputs and four semiconductor diagnostic outputs.

How is the device protected against electrical transients?


The unit has a rated insulation voltage of Ui 250V and an impulse withstand rating of 4,000V AC.

What are the environmental operating limits?


It is rated for operation between 0°C and +55°C and has an enclosure rating of IP20.

What supply constraints apply for installations in US-derived systems?


The device must be powered by a 24V DC source within 21V DC to 27V DC and, where applicable, operated with a UL Class 2 power supply.