SICK T4000 Safety Switch, Plastic
- RS Stock No.:
- 285-4318
- Mfr. Part No.:
- T4000-1RCA02
- Brand:
- SICK
Subtotal (1 unit)*
£775.83
(exc. VAT)
£931.00
(inc. VAT)
FREE delivery for orders over £60.00
Stocked by manufacturer
- Ready to ship from 14 January 2027
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | £775.83 |
*price indicative
- RS Stock No.:
- 285-4318
- Mfr. Part No.:
- T4000-1RCA02
- Brand:
- SICK
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | SICK | |
| Product Type | Safety Switch | |
| Actuator Included | No | |
| Housing Material | Plastic | |
| Series | T4000 | |
| IP Rating | IP20 | |
| Contact AC Voltage | 60V ac | |
| Contact DC Voltage | 24V dc | |
| Minimum Operating Temperature | 0°C | |
| Hazardous Area Certification | No | |
| Maximum Operating Temperature | 55°C | |
| Length | 114mm | |
| Width | 99mm | |
| Depth | 45mm | |
| Standards/Approvals | CE | |
| Select all | ||
|---|---|---|
Brand SICK | ||
Product Type Safety Switch | ||
Actuator Included No | ||
Housing Material Plastic | ||
Series T4000 | ||
IP Rating IP20 | ||
Contact AC Voltage 60V ac | ||
Contact DC Voltage 24V dc | ||
Minimum Operating Temperature 0°C | ||
Hazardous Area Certification No | ||
Maximum Operating Temperature 55°C | ||
Length 114mm | ||
Width 99mm | ||
Depth 45mm | ||
Standards/Approvals CE | ||
- COO (Country of Origin):
- DE
SICK T4000 Series Safety Switch, 24V DC Supply, IP20 - T4000-1RCA02
This safety switch is a non-contact guard interlock designed for industrial machine safety applications where enclosure protection and electrical monitoring are required. It is intended for use with control systems that accept relay outputs and operates from a 24V DC supply. The device provides status indication for power, outputs and errors, and is built for indoor, non-hazardous areas with a plastic enclosure suitable for contamination level 2 environments.
Features and Benefits:
• Category4 safety architecture offering high-risk reduction
• PL e performance level for stringent safety requirements
• Two safe N/O relay outputs for straightforward integration
• Relay response time ≤290 MS enabling timely fault detection
• Short-circuit protected with 6A gG fuse rating for safety
• PL e performance level for stringent safety requirements
• Two safe N/O relay outputs for straightforward integration
• Relay response time ≤290 MS enabling timely fault detection
• Short-circuit protected with 6A gG fuse rating for safety
Applications
• Suitable for machine-guard interlocking in production cells
• Ideal for assembly-line perimeter safety monitoring
• Used with control panels requiring relay-based outputs
• Can be used for diagnostics-rich safety circuits
• Suitable for indoor factory automation where IP20 suffices
• Ideal for assembly-line perimeter safety monitoring
• Used with control panels requiring relay-based outputs
• Can be used for diagnostics-rich safety circuits
• Suitable for indoor factory automation where IP20 suffices
What supply voltage is required for operation?
It operates from a 24V DC supply within a 21V to 27V DC window.
How are the outputs presented to control equipment?
Outputs are provided as relay contacts with two semiconductor diagnostic outputs.
What environmental temperature range is supported?
The unit is specified for operation between 0°C and +55°C.
What mechanical durability can be expected?
Mechanical life is specified as 10x10^6 switching cycles.