SICK STR1 Safety Switch Actuator Included, Vistal

Subtotal (1 unit)*

£157.65

(exc. VAT)

£189.18

(inc. VAT)

Add to Basket
Select or type quantity
Stock information currently inaccessible - Please check back later
Units
Per unit
1 +£157.65

*price indicative

RS Stock No.:
285-4289
Mfr. Part No.:
STR1-SAFM10P8
Brand:
SICK
Find similar products by selecting one or more attributes.
Select all

Brand

SICK

Product Type

Safety Switch

Actuator Included

Yes

Safety Contacts

1

Housing Material

Vistal

Series

STR1

Switch Contact Current

100mA

IP Rating

IP67, IP69K

Contact AC Voltage

230V ac

Minimum Operating Temperature

-30°C

Contact DC Voltage

24V dc

Maximum Operating Temperature

70°C

Hazardous Area Certification

No

Standards/Approvals

CE

Number of Head Directions

5

Depth

26mm

Length

18mm

Width

40mm

COO (Country of Origin):
MY

SICK STR1 Series Safety Switch, IP67/IP69K, Vistal Housing - STR1-SAFM10P8


This safety switch is a non-contact interlock device designed for industrial access protection, using RFID sensing to monitor guard positions and provide safe outputs for machine control. It operates from a 24V DC supply and offers self-monitoring semiconductor outputs for integration into safety circuits. The unit is built for harsh conditions with high ingress protection and supports multi-directional actuation for flexible mounting.

Features and Benefits:


• SIL3 safety integrity level for high-demand applications
• Category 4 and PL e performance for functional safety
• Two safe outputs with self-monitoring semiconductor design
• 10m cable fitted for straightforward panel connection
• IP67 IP69K ingress protection for wet and wash-down environments

Applications


• Suitable for production lines requiring guarded access monitoring
• Ideal for food-industry wash-down zones with high-pressure cleaning
• Used with safety relays for series-connected safety architectures
• Can be used for robotic cell perimeter protection
• Suitable for diagnostic-enabled control-cabinet safety wiring

What supply voltage range is required for operation?


The device accepts 24V DC with an operational window of 19.2V DC to 28.8V DC.

How are outputs and auxiliary functions provided?


It provides two safe OSSD outputs Plus one auxiliary contact with complementary switching.

What environmental temperatures can it withstand?


The unit is rated to operate between -30°C and +70°C for qualifying serial numbers

otherwise -10°C to +70°C applies.

What diagnostic or status feedback is available?


Integrated LEDs provide status indication and diagnostic information for system monitoring.

Related links