Schneider Electric Multi 9 Series Residual Current Circuit Breaker, 40 A, 4-Pole, 260 mA, Type A, 10 kA 250 V ac
- RS Stock No.:
- 211-2469
- Mfr. Part No.:
- M9R84440
- Brand:
- Schneider Electric
Subtotal (1 unit)*
£291.65
(exc. VAT)
£349.98
(inc. VAT)
Stock information currently inaccessible - Please check back later
Units | Per unit |
|---|---|
| 1 + | £291.65 |
*price indicative
- RS Stock No.:
- 211-2469
- Mfr. Part No.:
- M9R84440
- Brand:
- Schneider Electric
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Schneider Electric | |
| Product Type | Residual Current Circuit Breaker | |
| Current Rating | 40 A | |
| Number of Poles | 4 | |
| Range | Multi9 | |
| Series | Multi 9 | |
| Trip Sensitivity | 260mA | |
| Mount Type | DIN Rail | |
| Tripping Characteristics | Type A | |
| Terminal Type | Screw | |
| Standards/Approvals | REACH, RoHS | |
| Width | 72 mm | |
| Height | 81mm | |
| Depth | 60mm | |
| Breaking Capacity | 10kA | |
| Reset Actuator Type | Toggle Switch | |
| Tripping Mechanism | Electromagnetic | |
| Earth Leakage Protection Type | Type A | |
| Break Time | Instantaneous | |
| Rated AC Voltage | 250 V ac | |
| Select all | ||
|---|---|---|
Brand Schneider Electric | ||
Product Type Residual Current Circuit Breaker | ||
Current Rating 40 A | ||
Number of Poles 4 | ||
Range Multi9 | ||
Series Multi 9 | ||
Trip Sensitivity 260mA | ||
Mount Type DIN Rail | ||
Tripping Characteristics Type A | ||
Terminal Type Screw | ||
Standards/Approvals REACH, RoHS | ||
Width 72 mm | ||
Height 81mm | ||
Depth 60mm | ||
Breaking Capacity 10kA | ||
Reset Actuator Type Toggle Switch | ||
Tripping Mechanism Electromagnetic | ||
Earth Leakage Protection Type Type A | ||
Break Time Instantaneous | ||
Rated AC Voltage 250 V ac | ||
- COO (Country of Origin):
- ES
The Schneider Electric Multi 9 GFP series is a Residual current circuit breaker (RCCB) with a Type A-SI Earth-leakage protection class. They are used for control and disconnection of electric circuits, protection of people against electric shock by direct and indirect contacts, protection of installations against insulation faults, enhanced continuity of supply, during a series of close lightning strokes.
Enhanced earth leakage protection
Protection of installations against insulation faults
Related links
- Schneider Electric GFP RCCB 4 Pole 277V ac
- Schneider Electric GFP RCCB 4 Pole Type A, 415V ac
- Schneider Electric GFP RCCB 2 Pole 277V ac
- Schneider Electric GFP RCCB 2 Pole 240V ac
- Schneider Electric GFP RCCB 4 Pole 277V ac
- Schneider Electric GFP RCCB 2 Pole 277V ac
- Schneider Electric GFP RCCB 2 Pole 240V ac
- Schneider Electric GFP RCCB 2 Pole, 240V