Schneider Electric RCBO, 20A Current Rating, 2P Poles, 30mA Trip Sensitivity, Type C, Acti9 Range
- RS Stock No.:
- 654-789
- Mfr. Part No.:
- A9D19220
- Brand:
- Schneider Electric
Subtotal (1 unit)*
£326.09
(exc. VAT)
£391.31
(inc. VAT)
FREE delivery for orders over £50.00
New product - Preorder today
- 999,999,999 unit(s) shipping from 04 February 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
---|---|
1 + | £326.09 |
*price indicative
- RS Stock No.:
- 654-789
- Mfr. Part No.:
- A9D19220
- Brand:
- Schneider Electric
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | Schneider Electric | |
Current Rating | 20A | |
Number of Poles | 2 | |
Range | Acti9 | |
Series | iC60 | |
Trip Sensitivity | 30mA | |
Circuit Breaker Type | Thermal Magnetic Circuit Breaker | |
Tripping Characteristics | Type C | |
Select all | ||
---|---|---|
Brand Schneider Electric | ||
Current Rating 20A | ||
Number of Poles 2 | ||
Range Acti9 | ||
Series iC60 | ||
Trip Sensitivity 30mA | ||
Circuit Breaker Type Thermal Magnetic Circuit Breaker | ||
Tripping Characteristics Type C | ||
- COO (Country of Origin):
- TH
The Schneider Electric Acti9 iC60 is a modular residual current breaker with overcurrent protection (RCBO). It is a 2P circuit breaker with 1 protected pole, 20A In rated current and C tripping curve. The earth leakage protection class is A type with a sensitivity of 30mA. The earth-leakage protection time delay is instantaneous. The Icn rated short circuit breaking capacity is up to 10000A according IEC 61009-2-2 standard. Its unique Visitrip indicator reduces intervention time by showing the faulty circuit. Its Visisafe green strip guarantees the physical opening of the contacts to allow downstream maintenance. Its fast closing mechanism independent of manual operation improves its service life. This product is compliant with IEC 61009-1 and AS/NZS 61009.1 standards.
Device location in system is outgoer
Network frequency is 50 Hz
Network type is AC
Trip unit technology is thermal-magnetic
Network frequency is 50 Hz
Network type is AC
Trip unit technology is thermal-magnetic
Related links
- Schneider Electric RCBO 2P Poles Type C, Acti9 Range
- Schneider Electric RCBO 3P+N Poles Type C, Acti9 Range