Honeywell Technologies 26PC Series Low Pressure Sensor, Bridge Positive Output 0 psi, Relative Reading 30 psi
- RS Stock No.:
- 169-7657
- Mfr. Part No.:
- 26PCDFA6G
- Brand:
- Honeywell
Subtotal (1 box of 25 units)*
£3,582.37
(exc. VAT)
£4,298.85
(inc. VAT)
FREE delivery for orders over £60.00
In Stock
- 50 unit(s) ready to ship
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit | Per Box* |
|---|---|---|
| 25 + | £143.295 | £3,582.38 |
*price indicative
- RS Stock No.:
- 169-7657
- Mfr. Part No.:
- 26PCDFA6G
- Brand:
- Honeywell
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Honeywell | |
| Pressure Reading Type | Relative | |
| Product Type | Low Pressure Sensor | |
| Maximum Pressure Measurement | 30psi | |
| Minimum Pressure Measurement | 0psi | |
| Accuracy | ±0.25 % | |
| Output Type | Bridge Positive | |
| Terminal Type | 4-Pin | |
| Response Time | 1ms | |
| Minimum Supply Voltage | 2.5V dc | |
| Series | 26PC | |
| Maximum Supply Voltage | 16V | |
| Standards/Approvals | RoHS | |
| Minimum Operating Temperature | -40°C | |
| Maximum Operating Temperature | 85°C | |
| Select all | ||
|---|---|---|
Brand Honeywell | ||
Pressure Reading Type Relative | ||
Product Type Low Pressure Sensor | ||
Maximum Pressure Measurement 30psi | ||
Minimum Pressure Measurement 0psi | ||
Accuracy ±0.25 % | ||
Output Type Bridge Positive | ||
Terminal Type 4-Pin | ||
Response Time 1ms | ||
Minimum Supply Voltage 2.5V dc | ||
Series 26PC | ||
Maximum Supply Voltage 16V | ||
Standards/Approvals RoHS | ||
Minimum Operating Temperature -40°C | ||
Maximum Operating Temperature 85°C | ||
- COO (Country of Origin):
- CN
Honeywell 26PC Series Pressure Sensor, 30psi Maximum Pressure, ±0.25% Accuracy - 26PCDFA6G
This pressure sensor converts relative pressure into a bridge-format electrical output for monitoring and control in industrial and electronic systems. It is engineered for low-pressure measurement and integration with control electronics, offering Rapid electrical response and a Compact four-pin connection suitable for automated and bench equipment.
Features and Benefits:
• ±0.25% accuracy provides precise measurement fidelity
• 0-30psi range supports low-pressure process control
• 1ms response delivers fast transient detection
• 4-pin Terminal enables simple electrical integration
• Operates from 2.5V to 16V supply for flexible power arrangements
• Withstands -40 to 85°C for broad industrial environments
• 0-30psi range supports low-pressure process control
• 1ms response delivers fast transient detection
• 4-pin Terminal enables simple electrical integration
• Operates from 2.5V to 16V supply for flexible power arrangements
• Withstands -40 to 85°C for broad industrial environments
Applications
• Suitable for pneumatic actuator pressure monitoring
• Ideal for process control in low-pressure manifolds
• Used for leak detection in assembly and test rigs
• Can be used with data acquisition systems for Rapid sampling
• Suitable for HVAC modulation valve feedback loops
• Ideal for process control in low-pressure manifolds
• Used for leak detection in assembly and test rigs
• Can be used with data acquisition systems for Rapid sampling
• Suitable for HVAC modulation valve feedback loops
What electrical output format does it use and why is that useful?
It provides a bridge-type output which is compatible with differential amplifiers and ADC front-ends for accurate signal conditioning in control systems.
How does the sensor behave at extremes of its temperature range?
Functional operation is maintained from -40 to 85°C, with performance characterised across that span to support installations in cold stores or warmer plant areas.
What supply constraints should I consider when integrating it?
The device accepts supplies as low as 2.5V and up to 16V, allowing connection to a wide range of logic and industrial power rails without additional regulation in many cases.
What measurement orientation or mounting considerations affect readings?
As a relative pressure device, it measures differential pressure relative to ambient or a reference, so installation should ensure the reference port reflects the intended baseline for accurate readings.
Related links
- Honeywell Technologies 26PC Series Low Pressure Sensor Relative Reading 30 psi
- Honeywell Technologies 26PC Series Pressure Sensor Relative Reading 30 psi
- Honeywell Technologies 26PC Series Low Pressure Sensor Relative Reading 100 psi
- Honeywell Technologies 26PC Series Pressure Sensor Differential Reading 30 psi
- Honeywell Technologies 26PC Series Pressure Sensor Relative Reading 5 psi
- Honeywell Technologies 26PC Series Pressure Sensor Differential Reading 1 psi
- Honeywell Technologies 26PC Series Pressure Sensor Gauge Reading 15 psi
- Honeywell Technologies 26PC Series Pressure Sensor Gauge Or Differential Reading 60 psi