Druck DPI 800 0 bar to 2 bar Pressure Calibrator
- RS Stock No.:
- 465-7694
- Mfr. Part No.:
- I800S-1-465-7694
- Brand:
- Druck
Subtotal (1 unit)*
£1,392.84
(exc. VAT)
£1,671.41
(inc. VAT)
FREE delivery for orders over £60.00
In Stock
- Plus 11 unit(s) shipping from 30 November 2026
- Plus 8 unit(s) shipping from 30 November 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | £1,392.84 |
*price indicative
- RS Stock No.:
- 465-7694
- Mfr. Part No.:
- I800S-1-465-7694
- Brand:
- Druck
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Druck | |
| Maximum Pressure Measurement | 2bar | |
| Product Type | Pressure Calibrator | |
| Battery Type | AA Alkaline | |
| Accuracy | ±0.01 % | |
| Minimum Pressure Measurement | 0bar | |
| Pressure Port Type | Absolute | |
| Model Number | DPI 800 | |
| Data Logging | Yes | |
| Display Type | LCD Backlight | |
| Current Loop Measurement | Yes | |
| Leak Testing | Yes | |
| Power Source | Battery | |
| Minimum Operating Temperature | -10°C | |
| Weight | 500g | |
| Maximum Operating Temperature | 50°C | |
| Battery Life | 50h | |
| Length | 180mm | |
| Standards/Approvals | BS EN61010:2001, BS EN61326-1:1998 + A2:2001, CE | |
| Width | 85mm | |
| Height | 50mm | |
| Hazardous Area Certification | No | |
| Select all | ||
|---|---|---|
Brand Druck | ||
Maximum Pressure Measurement 2bar | ||
Product Type Pressure Calibrator | ||
Battery Type AA Alkaline | ||
Accuracy ±0.01 % | ||
Minimum Pressure Measurement 0bar | ||
Pressure Port Type Absolute | ||
Model Number DPI 800 | ||
Data Logging Yes | ||
Display Type LCD Backlight | ||
Current Loop Measurement Yes | ||
Leak Testing Yes | ||
Power Source Battery | ||
Minimum Operating Temperature -10°C | ||
Weight 500g | ||
Maximum Operating Temperature 50°C | ||
Battery Life 50h | ||
Length 180mm | ||
Standards/Approvals BS EN61010:2001, BS EN61326-1:1998 + A2:2001, CE | ||
Width 85mm | ||
Height 50mm | ||
Hazardous Area Certification No | ||
RoHS Status: Exempt
- COO (Country of Origin):
- GB
Druck Pressure Calibrator, 2 bar Maximum Pressure, ±0.01% Accuracy - I800S-1-465-7694
This pressure calibrator provides portable, battery-operated pressure measurement and diagnostic capability for field and workshop tasks. It is designed to measure absolute pressure up to 2 bar while offering high-resolution results and a backlit LCD for readable data in varied lighting. The instrument supports routine leak testing and continuous monitoring through internal data logging, and it operates across a practical ambient range for typical maintenance environments.
Features and Benefits:
• ±0.01% accuracy ensuring precise calibration results
• Data logging capability enabling extended measurement records
• Battery operation delivering up to 50 h of continuous use
• Absolute pressure port allowing measurement against vacuum
• Leak-testing function supporting seal and integrity checks
• Data logging capability enabling extended measurement records
• Battery operation delivering up to 50 h of continuous use
• Absolute pressure port allowing measurement against vacuum
• Leak-testing function supporting seal and integrity checks
Applications
• Suitable for commissioning pneumatic control loops
• Ideal for on-site instrument calibration and verification
• Used for maintenance of process plant pressure sensors
• Can be used for pressure transmitter loop checks
• Suitable for service teams requiring portable diagnostics
• Ideal for on-site instrument calibration and verification
• Used for maintenance of process plant pressure sensors
• Can be used for pressure transmitter loop checks
• Suitable for service teams requiring portable diagnostics
What power source does it use and how long will it run?
It is powered by AA alkaline batteries and provides approximately 50 h of operation.
What pressure range can it measure and what port type is fitted?
It measures from 0 bar up to 2 bar and utilises an absolute pressure port.
Is it suitable for use in hazardous-area installations?
It does not carry hazardous-area certification and should not be used where certification is required.
What display and Interface features aid field readability?
The instrument uses an LCD with backlight to maintain visibility in low-light conditions.
Which standards and approvals are applied to its design?
It conforms to BS EN 61010:2001 and BS EN 61326-1:1998 + A2:2001 and carries CE marking.
Related links
- Druck DPI 800 0 bar to 2 bar Pressure Calibrator, RSCAL
- Druck DPI 800 25 mbar to 200 mbar Pressure Calibrator
- Druck DPI 800 25 mbar to 200 mbar Pressure Calibrator, RSCAL
- Druck DPI 611 -1 bar to 2 bar Pressure Calibrator
- Druck DPI 611 -1 bar to 7 bar Pressure Calibrator
- Druck DPI 615 0 bar to 2 bar Pressure Calibrator
- Druck DPI 615 0 bar to 20 bar Pressure Calibrator
- Druck DPI 612 Flex -1 bar to 2 bar Pressure Calibrator