Siemens SIMATIC S7-1500 Series PLC CPU, Digital Output, 20-Input, Digital Input
- RS Stock No.:
- 282-3562
- Mfr. Part No.:
- 6ES7672-7AC02-0YA0
- Brand:
- Siemens
Subtotal (1 unit)*
£1,336.23
(exc. VAT)
£1,603.48
(inc. VAT)
FREE delivery for orders over £60.00
Stocked by manufacturer
- Ready to ship from 25 May 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | £1,336.23 |
*price indicative
- RS Stock No.:
- 282-3562
- Mfr. Part No.:
- 6ES7672-7AC02-0YA0
- Brand:
- Siemens
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Siemens | |
| Product Type | PLC CPU | |
| Series | SIMATIC S7-1500 | |
| Number of Inputs | 20 | |
| Output Type | Digital | |
| Input Type | Digital | |
| Number of Outputs | 20 | |
| Minimum Operating Temperature | -30°C | |
| Maximum Operating Temperature | 60°C | |
| Standards/Approvals | SNMP/DCP Read Only (based on communication and security features), IEC 62439-2 (for Media Redundancy Protocol), PROFINET Security Class 1 | |
| Programming Language Used | STL, SCL, LAD, Graph, FBD, CFC | |
| Communication Port Type | RJ45 | |
| Number of Communication Ports | 3 | |
| Display Included | No | |
| Select all | ||
|---|---|---|
Brand Siemens | ||
Product Type PLC CPU | ||
Series SIMATIC S7-1500 | ||
Number of Inputs 20 | ||
Output Type Digital | ||
Input Type Digital | ||
Number of Outputs 20 | ||
Minimum Operating Temperature -30°C | ||
Maximum Operating Temperature 60°C | ||
Standards/Approvals SNMP/DCP Read Only (based on communication and security features), IEC 62439-2 (for Media Redundancy Protocol), PROFINET Security Class 1 | ||
Programming Language Used STL, SCL, LAD, Graph, FBD, CFC | ||
Communication Port Type RJ45 | ||
Number of Communication Ports 3 | ||
Display Included No | ||
- COO (Country of Origin):
- DE
Siemens SIMATIC S7-1500 Series PLC CPU, 20 Inputs, 20 Outputs - 6ES7672-7AC02-0YA0
This plc CPU is a programmable logic controller central unit designed for industrial automation and control over Ethernet-based networks. It manages digital inputs and outputs while supporting multiple programming methods for logic development, and it operates across a wide temperature span for use in demanding plant environments.
Features and Benefits:
• 20 digital inputs provide straightforward sensor interfacing and state detection
• 20 digital outputs enable direct actuation of field devices
• Three communication ports allow segregated network and device connections
• RJ45 port type facilitates standard Ethernet link to PROFINET systems
• Operating range -30 to 60°C ensures functionality in extreme ambient conditions
• Supports STL, SCL, LAD, FBD, CFC for flexible programming and maintenance
• 20 digital outputs enable direct actuation of field devices
• Three communication ports allow segregated network and device connections
• RJ45 port type facilitates standard Ethernet link to PROFINET systems
• Operating range -30 to 60°C ensures functionality in extreme ambient conditions
• Supports STL, SCL, LAD, FBD, CFC for flexible programming and maintenance
Applications
• Suitable for PROFINET-based factory automation control loops
• Ideal for machine control requiring 20 I/O channels
• Used with industrial networks needing media redundancy support
• Can be used for monitoring systems utilising SNMP/DCP read-only access
• Suitable for installations requiring PROFINET Security Class 1 devices
• Ideal for machine control requiring 20 I/O channels
• Used with industrial networks needing media redundancy support
• Can be used for monitoring systems utilising SNMP/DCP read-only access
• Suitable for installations requiring PROFINET Security Class 1 devices
Which communication protocols and security levels are supported?
The unit implements PROFINET with Security Class 1 and offers read-only SNMP/DCP capability based on its communication and security features.
Does the controller support network redundancy for enhanced availability?
Yes, it provides compatibility with IEC 62439-2 Media Redundancy Protocol to maintain network continuity in ring topologies.
What programming options are available for developing control logic?
You can program using statement list, structured control language, ladder, function Block diagram, graph and continuous function chart formats to suit different engineering workflows.
How many network interfaces are provided for separating traffic?
There are three communication ports to enable dedicated connections for different network segments or devices.
Related links
- Siemens SIMATIC S7-1500 Series PLC CPU Ethernet-Based Output Counter, Digital Based On
- Siemens SIMATIC S7-1500 Series PLC CPU, 20-Input20 Outputs
- Siemens SIMATIC S7-1500 Series PLC CPU, 20-Input32 Outputs
- Siemens SIMATIC S7-1500 Series Digital Input
- Siemens SIMATIC S7-1500 Series PLC CPU Digital Input
- Siemens SIMATIC S7-1500 Series PLC CPU 20-Input20 Outputs
- Siemens SIMATIC S7-1500T Series PLC CPU for Use with SIMATIC S7-1500 Series 20-Input
- Siemens SIMATIC S7-1500 Series PLC I/O Module Digital Input
