MOXA Remote I/O Module ioLogik R1200 Digital 48V dc
- RS Stock No.:
- 256-3716
- Distrelec Article No.:
- 300-20-778
- Mfr. Part No.:
- ioLogik R1210
- Brand:
- MOXA
Subtotal (1 unit)*
£190.84
(exc. VAT)
£229.01
(inc. VAT)
FREE delivery for orders over £60.00
Temporarily out of stock
- 11 unit(s) shipping from 05 October 2026
- Plus 3 unit(s) shipping from 16 November 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | £190.84 |
*price indicative
- RS Stock No.:
- 256-3716
- Distrelec Article No.:
- 300-20-778
- Mfr. Part No.:
- ioLogik R1210
- Brand:
- MOXA
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | MOXA | |
| Module Type | RS485 | |
| Product Type | Remote I/O Module | |
| Input Type | Digital | |
| Mount Type | DIN Rail | |
| Interface Type | RS485 | |
| Maximum Supply Voltage | 48V dc | |
| Number of I/Os | 16 | |
| Maximum Operating Temperature | +75°C | |
| Width | 27.8mm | |
| Length | 124mm | |
| Depth | 84mm | |
| Series | ioLogik R1200 | |
| Standards/Approvals | WEEE, IEC 60068-2-27, Telcordia SR332, EN 61000-6-2/-6-4, IEC 60068-2-6, CRoHS, UL 508, IEC 61000-4-2, IEC 61000-4-8, IEC 61000-4-6, EN 55032/24, CISPR 32, IEC 61000-4-3, RoHS, IEC 61000-4-5, IEC 61000-4-4, FCC Part 15B Class A | |
| Select all | ||
|---|---|---|
Brand MOXA | ||
Module Type RS485 | ||
Product Type Remote I/O Module | ||
Input Type Digital | ||
Mount Type DIN Rail | ||
Interface Type RS485 | ||
Maximum Supply Voltage 48V dc | ||
Number of I/Os 16 | ||
Maximum Operating Temperature +75°C | ||
Width 27.8mm | ||
Length 124mm | ||
Depth 84mm | ||
Series ioLogik R1200 | ||
Standards/Approvals WEEE, IEC 60068-2-27, Telcordia SR332, EN 61000-6-2/-6-4, IEC 60068-2-6, CRoHS, UL 508, IEC 61000-4-2, IEC 61000-4-8, IEC 61000-4-6, EN 55032/24, CISPR 32, IEC 61000-4-3, RoHS, IEC 61000-4-5, IEC 61000-4-4, FCC Part 15B Class A | ||
- COO (Country of Origin):
- TW
MOXA Remote I/O Module, 16 I/Os, 48V DC Maximum Supply Voltage - ioLogik R1210
This remote I/O module provides Compact remote digital I/O via an RS485 Interface for industrial control systems. Designed for DIN-rail installation, it enables distributed monitoring and switching of 16 digital channels within automation and electrical control networks. The unit is intended for use where a Compact, rail-mounted I/O node is required and where operation in electrically noisy or elevated-temperature environments is expected.
Features and Benefits:
• 16 digital channels for expanded field I/O capacity
• RS485 Interface enabling robust serial-bus connections
• 48V DC maximum supply voltage for higher-voltage control systems
• Rated to operate up to +75 °C for elevated-temperature installations
• Conforms to multiple EMI/EMC and safety standards for interference resilience
• DIN-rail mounting simplifies panel integration and replacement
• RS485 Interface enabling robust serial-bus connections
• 48V DC maximum supply voltage for higher-voltage control systems
• Rated to operate up to +75 °C for elevated-temperature installations
• Conforms to multiple EMI/EMC and safety standards for interference resilience
• DIN-rail mounting simplifies panel integration and replacement
Applications
• Suitable for distributed sensor and actuator connection in PLC systems
• Ideal for remote monitoring in factory automation networks
• Used with serial field buses in building management systems
• Can be used for expanding I/O in machine control cabinets
• Suitable for installations requiring Compact rail-mounted I/O points
• Ideal for remote monitoring in factory automation networks
• Used with serial field buses in building management systems
• Can be used for expanding I/O in machine control cabinets
• Suitable for installations requiring Compact rail-mounted I/O points
How many I/O points does it provide and what type are they?
It supplies sixteen digital I/O points suitable for discrete input and output signalling in control applications.
What mounting method is used for installation in control panels?
The unit is designed for DIN-rail mounting to allow straightforward attachment within standard control enclosures.
Which electrical Interface is used to communicate with controllers?
Communication is via an RS485 serial Interface appropriate for multi-drop industrial networks.
What environmental or EMC qualifications support deployment near motors or drives?
It meets a wide range of EMI/EMC and electrical standards covering immunity and emissions to support use in electrically noisy industrial environments.
Related links
- MOXA Remote I/O Module ioLogik R1200 Digital 48V dc
- MOXA Remote I/O Module ioLogik R1200 Digital 28.8V
- MOXA Remote I/O Module ioLogik R1200 Analogue 48V dc
- MOXA Remote I/O Module ioLogik 2500 Digital 48V
- MOXA Remote I/O Module ioLogik E2200 Digital 36V
- Weidmüller Remote I/O Module NX Digital 48V dc
- WAGO Input Module 750 Digital 48V dc
- MOXA Ethernet Module ioLogik E1200 Digital 36V