Myrra 6 to 2 x 24 V 2 Output Through Hole PCB Transformer, EN 61558-2-6, UL 1585, CEI 85, EN 60950 30 VA
- RS Stock No.:
- 174-0248
- Mfr. Part No.:
- 44384
- Brand:
- Myrra
Image representative of range
Bulk discount available
Subtotal (1 unit)*
£11.07
(exc. VAT)
£13.28
(inc. VAT)
FREE delivery for orders over £50.00
Limited stock
- 9 left, ready to ship from another location
- Plus 15 left, shipping from 27 February 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 - 24 | £11.07 |
| 25 - 49 | £10.52 |
| 50 - 99 | £10.00 |
| 100 - 249 | £8.90 |
| 250 + | £8.46 |
*price indicative
- RS Stock No.:
- 174-0248
- Mfr. Part No.:
- 44384
- Brand:
- Myrra
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Myrra | |
| Product Type | PCB Transformer | |
| Secondary Voltage | 6 to 2 x 24 V | |
| Primary Voltage | 117 V, 230 V | |
| Number of Outputs | 2 | |
| Length | 70mm | |
| Width | 59 mm | |
| Depth | 48.75mm | |
| Power | 30VA | |
| Weight | 700g | |
| Mount Type | Through Hole | |
| Isolation Voltage | 4kV | |
| Maximum Operating Temperature | 250°C | |
| Series | 44000 | |
| Minimum Operating Frequency | 50Hz | |
| Maximum Operating Frequency | 60Hz | |
| Standards/Approvals | EN 61558-2-6, UL 1585, CEI 85, EN 60950 | |
| Select all | ||
|---|---|---|
Brand Myrra | ||
Product Type PCB Transformer | ||
Secondary Voltage 6 to 2 x 24 V | ||
Primary Voltage 117 V, 230 V | ||
Number of Outputs 2 | ||
Length 70mm | ||
Width 59 mm | ||
Depth 48.75mm | ||
Power 30VA | ||
Weight 700g | ||
Mount Type Through Hole | ||
Isolation Voltage 4kV | ||
Maximum Operating Temperature 250°C | ||
Series 44000 | ||
Minimum Operating Frequency 50Hz | ||
Maximum Operating Frequency 60Hz | ||
Standards/Approvals EN 61558-2-6, UL 1585, CEI 85, EN 60950 | ||
- COO (Country of Origin):
- FR
30 VA moulded transformers - type EI 66 / 23.2
Secondary voltages are nominal load voltages on resistive loads.
Encapsulated – Toroidal
Note
Fixing screws not provided
Approvals
UL, VDE
Related links
- Myrra 24V ac 2 Output Through Hole PCB Transformer, 30VA
- Myrra 24V ac 2 Output Through Hole PCB Transformer, 24VA
- Myrra 24V ac 2 Output Through Hole PCB Transformer, 5VA
- Myrra 24V ac 2 Output Through Hole PCB Transformer, 40VA
- Myrra 24V ac 2 Output Through Hole PCB Transformer, 60VA
- Myrra 24V ac 2 Output Through Hole PCB Transformer, 2.3VA
- Myrra 24V ac 2 Output Through Hole PCB Transformer, 1.5VA
- Myrra 24V ac 2 Output Through Hole PCB Transformer, 6VA
