Fluke 3000 FC 3000 FC Handheld Digital Multimeter True RMS, 400 mA ac, 400 mA dc, 1 kV ac - RSCAL Calibrated
- RS Stock No.:
- 810-8931
- Mfr. Part No.:
- FLK-3000 FC
- Brand:
- Fluke
Subtotal (1 unit)*
£446.50
(exc. VAT)
£535.80
(inc. VAT)
FREE delivery for orders over £50.00
- 9 left, ready to ship
- Plus 10 left, shipping from 01 April 2026
- Plus 34 left, shipping from 15 April 2026
Units | Per unit |
|---|---|
| 1 + | £446.50 |
*price indicative
- RS Stock No.:
- 810-8931
- Mfr. Part No.:
- FLK-3000 FC
- Brand:
- Fluke
Select all | Attribute | Value |
|---|---|---|
| Brand | Fluke | |
| Product Type | Multimeter | |
| Multimeter Type | Handheld | |
| Model Number | 3000 FC | |
| Display Type | Digital | |
| Resistance Resolution | 100mΩ | |
| Functions Measured | AC Current, AC Voltage, DC Current, DC Voltage, Resistance, Temperature | |
| Maximum DC Voltage Measurement | 1kV dc | |
| Maximum AC Voltage Measurement | 1kV ac | |
| Maximum Resistance Measurement | 50mΩ | |
| Maximum AC Current Measurement | 400mA ac | |
| Maximum DC Current Measurement | 400mA dc | |
| True RMS | Yes | |
| AC Voltage Accuracy | ±1 % rdg | |
| AC Current Accuracy | ±1.5 % | |
| DC Current Accuracy | ±0.5 % | |
| DC Voltage Accuracy | ±0.09 % | |
| DC Voltage Resolution | 0.1 mV dc | |
| AC Current Resolution | 0.01mA ac | |
| AC Voltage Resolution | 0.1mV ac | |
| DC Current Resolution | 0.01mA dc | |
| Maximum Frequency | 99.99kHz | |
| Resistance Measurement Accuracy | ±0.5 % rdg | |
| Minimum Operating Temperature | -10°C | |
| Battery Life | 250h | |
| Maximum Operating Temperature | 50°C | |
| Weight | 487.5g | |
| Width | 93mm | |
| Series | 3000 FC | |
| Height | 47.5mm | |
| Length | 207mm | |
| Standards/Approvals | No | |
| Safety Category Level | CAT III, CAT IV | |
| Calibrated | RSCAL | |
| Safety Category Voltage | 1000V | |
| Battery Type | AA | |
| Select all | ||
|---|---|---|
Brand Fluke | ||
Product Type Multimeter | ||
Multimeter Type Handheld | ||
Model Number 3000 FC | ||
Display Type Digital | ||
Resistance Resolution 100mΩ | ||
Functions Measured AC Current, AC Voltage, DC Current, DC Voltage, Resistance, Temperature | ||
Maximum DC Voltage Measurement 1kV dc | ||
Maximum AC Voltage Measurement 1kV ac | ||
Maximum Resistance Measurement 50mΩ | ||
Maximum AC Current Measurement 400mA ac | ||
Maximum DC Current Measurement 400mA dc | ||
True RMS Yes | ||
AC Voltage Accuracy ±1 % rdg | ||
AC Current Accuracy ±1.5 % | ||
DC Current Accuracy ±0.5 % | ||
DC Voltage Accuracy ±0.09 % | ||
DC Voltage Resolution 0.1 mV dc | ||
AC Current Resolution 0.01mA ac | ||
AC Voltage Resolution 0.1mV ac | ||
DC Current Resolution 0.01mA dc | ||
Maximum Frequency 99.99kHz | ||
Resistance Measurement Accuracy ±0.5 % rdg | ||
Minimum Operating Temperature -10°C | ||
Battery Life 250h | ||
Maximum Operating Temperature 50°C | ||
Weight 487.5g | ||
Width 93mm | ||
Series 3000 FC | ||
Height 47.5mm | ||
Length 207mm | ||
Standards/Approvals No | ||
Safety Category Level CAT III, CAT IV | ||
Calibrated RSCAL | ||
Safety Category Voltage 1000V | ||
Battery Type AA | ||
RoHS Status: Exempt
- COO (Country of Origin):
- US
Fluke Multimeter, 1000V Maximum DC Voltage, True RMS Functionality - FLK-3000 FC
Features & Benefits
• True RMS measurement for accurate non‑sinusoidal waveforms
• 400 mA maximum current range for precision current checks
• Frequency measurement to 99.99 kHz for signal verification
• Resistance down to 50 mΩ for low‑ohm integrity testing
• AA battery operation with 250 h minimum battery life for prolonged field use
Applications
• Ideal for preventative maintenance log collection and trend analysis
• Used for motor drive frequency and signal validation in automation systems
• Can be used for HVAC temperature checks via K‑type probes
• Used with remote clamp modules for non‑intrusive current monitoring
How is logged data retrieved for analysis on a PC?
What wireless range can be expected through typical site obstacles?
How does the instrument handle non‑sine AC voltages for accuracy?
What logging capacity and granularity are available for extended monitoring?
Which environmental conditions affect measurement performance?
Note
Supplied with
Related links
- Fluke 3000 FC 3000 FC Handheld Digital Multimeter True RMS 400 mA Max, 1000 V ac Max
- Fluke V3000 FC 3000 FC Handheld Digital Multimeter True RMS 1000 V Max
- Fluke V3000 FC 3000 FC Handheld Digital Multimeter True RMS 1000 V ac Max
- Fluke V3001 FC 3000 FC Handheld Digital Multimeter 1000 V Max
- Fluke V3001 FC 3000 FC Handheld Digital Multimeter 1000 V ac Max
- RS PRO S2 Handheld Digital Multimeter True RMS 400 mA Max, 1000 V Max
- RS PRO S2 Handheld Digital Multimeter True RMS 400 mA Max, 1000 V ac Max
- Facom 714APF Handheld Multimeter True RMS 400 mA Max, 600 V ac Max